• Title/Summary/Keyword: unit factor

Search Result 1,638, Processing Time 0.029 seconds

Data Processing Method of Radar Processor Unit Test Equipment (레이다처리장치 시험장비의 데이터 처리방안)

  • Lee, Mincheol;Kim, Yong-min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.767-775
    • /
    • 2018
  • To develop and check a Radar Processor Unit, checking the function and performance of the requirement is very important factor in developing Radar. General methods for verifying the Radar is simulation test, environment linkage test and field operation test, firstly, in case of requirement analysis phase, verify Radar algorithm and design by using mathematical method based simulation test method, and secondly, in case of unit test and integrated test phase, Test Equipment is set to simulate radar environment in the lab to verify radar function and performance. Lastly, field operation test phase is carried out to confirm the function and performance after it is mounted on the actual equipment. To successfully develop Radar Processor Unit, using the method of field operation test method after sufficient test cases are tested in radar environmental interlocking method in order to save cost and testing period and because of this reason, development of the Radar Processor Unit Test Equipment is becoming very important factor. In this paper, we introduce the concept of test equipment development and important factors in test equipment, which are target simulation, data processing and device interlocking.

Economic Feasibility Analysis for Development of Small Hydropower Using Agricultural Reservoirs (농업용 저수지의 소수력 개발을 위한 경제성 분석)

  • Woo, Jae-Yeoul;Kim, Jin-Soo;Jang, Hoon;Kim, Young-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • This study was conducted to investigate the effect of hydropower factors (watershed, gross head), operation ratio and unit electricity cost on the benefit-cost ratio (B/C ratio) of small hydropower using agricultural reservoirs. The equation of B/C ratio was expressed as a function of watershed area, gross head, operation ratio and unit electricity cost. The benefit increased with watershed area, gross head and unit electricity cost, while the cost increased with watershed area and gross head but decreased with operation ratio. The B/C ratio increased with watershed area, gross head, operation ratio and unit electricity cost. While the effect of gross head on the B/C ratio decreased with watershed area, the effect of operation ratio and unit electricity cost on the B/C ratio increased with watershed area. The operation ratio is an important factor to affect the B/C ratio and therefore we need to develop hydropower for the heightened dams to expect high operation ratio due to continuous water release. The unit electricity cost is also an important factor to affect the B/C ratio and the B/C ratio was always below 1 unless unit electricity cost is over 60 Won/kWh under given conditions. The reservoirs with economic feasibility for small hydropower development were three in 21 when the equation of B/C ratio was appled to the study reservoirs. The results can be used to choose the appropriate reservoir with economic feasibility for development of small hydropower.

A study on the impact on local economy by relocation of military unit : mainly with the case of Army Division 35 (군부대 이전이 지역 상권에 미치는 영향에 관한 연구 : 육군 35사단 사례 중심으로)

  • Namkung, Seung-pill;Park, Sang-Hyuk;Kim, Seung-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.69-74
    • /
    • 2018
  • This study is the basic data on how much the relocation of military unit influenced to local economy based on the survey targeting local merchants in order to analyze the impact on local economy by the relocation of military unit. That is, this study has actually verified the impact of "sales volume factor, floating population factor, regular customers factor" so questionnaires were distributed and collected targeting local merchants. Research results The impact before and after the relocation of army division 35 was verified to be meaningful and practical. This study verified that the relocation of army division 35 has influence the local economy, more research of impact on the local economy by the relocation of military unit shall be continued.

New evidence on mechanisms of action of spa therapy in rheumatic diseases

  • Tenti, Sara;Fioravanti, Antonella;Guidelli, Giacomo Maria;Pascarelli, Nicola Antonio;Cheleschi, Sara
    • CELLMED
    • /
    • v.4 no.1
    • /
    • pp.3.1-3.8
    • /
    • 2014
  • Spa represents a treatment widely used in many rheumatic diseases (RD). The mechanisms by which immersion in mineral or thermal water ameliorates RD are not fully understood. The net benefit is probably the result of a combination of factors, among which the mechanical, thermal and chemical effects are most prominent. Buoyancy, immersion, resistance and temperature play important roles. According to the gate theory, pain relief may be due to the pressure and temperature of the water on skin; heat may reduce muscle spasm and increase the pain threshold. Mud-bath therapy increases plasma ${\beta}$-endorphin levels and secretion of corticotrophin, cortisol, growth hormone and prolactin. It has recently been demonstrated that thermal mud-bath therapy induces a reduction in circulating levels of prostaglandin E2, leukotriene B4, interleukin-$1{\beta}$ and tumour necrosis factor-${\alpha}$, important mediators of inflammation and pain. Furthermore, balneotherapy has been found to cause an increase in insulin-like growth factor-1, which stimulates cartilage metabolism, and transforming growth factor-${\beta}$. Beneficial anti-inflammatory and anti-degenerative effects of mineral water were confirmed in chondrocytes cultures, too. Various studies in vitro and in humans have highlighted the positive action of mud-packs and thermal baths, especially sulphurous ones, on the oxidant/antioxidant system. Overall, thermal stress has an immunosuppressive effect. Many other non-specific factors may also contribute to the beneficial effects observed after spa therapy in some RD, including effects on cardiovascular risk factors (e.g. adipokines) and changes in the environment, pleasant surroundings and the absence of work duties.

Sorghum TCP transcription factor MULTISEED1 affects grain yield regulating at pedicellate spikelet fertility

  • Lee, Young Koung;Jiao, Yinping;Gladman, Nicholas;Chopra, Ratan;Burow, Gloria;Burke, John;Xin, Zhanguo;Ware, Doreen
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.25-25
    • /
    • 2017
  • Inflorescence architecture mainly contributes to final grain yield in crops. Sorghum inflorescence is basically composed of one fertile sessile spikelet (SS) and two infertile pedicellate spikelets (PS). To identify regulatory factors involved in the inflorescence architecture, we screened an EMS mutagenesis population from the pedigreed sorghum mutant library. We found inflorescent architecture mutants, named as multi-seed mutants, msd, with gained fertile ability in PS and also an increased number of floral branches. In natural sorghum populations, it is not common that are fertile. A detailed dissection of developmental stages of wild type and msd1 mutant described that the PS in wild type do not have floral organs, including ovary, stigma, filament and anther, while the msd1 mutants generate intact floral organ in the sessile spikelet. We found MSD1 encoded a TCP transcription factor using bulk segregant analysis (BSA) of F2 population, and was a strongly enriched expression during inflorescence developmental stages. We proposed that MSD1 functions to suppress floral organ maintenance at PS during inflorescence development in Sorghum. To explore the regulatory network associated with PS fertility, whole genome expression profiling was performed at 4 different developmental stages in 6 various tissue types between wild type and msd1. Taken together, we demonstrated that MSD1 was involved in the plant hormone and maybe influenced program cell death in PS via the activation of plant hormonal pathway.

  • PDF

The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System (배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정)

  • Jang, Jeong-Tae;Jeon Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Effect of Distance and Restraint Degree between Fillet and Butt Weldment on Residual Stress Redistribution at each Weldment (필릿과 맞대기 용접부 간의 간격 및 구속도에 따른 잔류응력 재분포 특성에 관한 연구)

  • Jin, Hyung-Kook;Lee, Dong-Ju;Shin, Sang-Beom
    • Journal of Welding and Joining
    • /
    • v.28 no.3
    • /
    • pp.59-64
    • /
    • 2010
  • The purpose of this study is to identify the principal factor controlling transverse residual stress at the weldment for joining unit hull blocks. In order to do it, the comprehensive FE analyses were carried out to evaluate the effect of distance between fillet and butt weldments, stiffener span and in-plane restraint degree on the amount and distribution of transverse residual stress in way of the weldments between unit hull blocks. In accordance with FEA results, principal factor controlling the amount of transverse residual stress at the weldments was identified as in-plane restraint degree of butt weldment for unit blocks. The effect of other variables on the transverse residual stress was very small relatively.

An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

Unit Loading Factor of Nitrogen and Phosphorus for Controlling Eutrophication of Youngsan Lake (영산호의 부영양화방지를 위한 질소, 인의 배출원단위에 관한 조사연구)

  • 류일광;이치영;강영식;김관천
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.51-58
    • /
    • 1989
  • In order to estimate unit loading factors of N, and P for controlling eutrophication of Youngsan lake. This study was performed in 4 kinds of pollutant sources from domestic sewage, industrial waste water, livestock stall waste water and drainage of agricultural area during the period from april to october 1988. These results were as follows: 1. The sewage flow for domestic waste water was 191.2 l/capita, day and that of the gray and toilet waste water among the domestic waste water were shown 152.9 l/capita, day(80%) and 38.3 l/capita, day(20%), respectively. 2. The unit loading factor total nitrogen(T-N) for domestic waste water was 7.582g/capita, day, and that of the gray and toilet waste water among the domestic waste water were 1.826g/ capita, day(24.1%) and 5.756g/capita, day(75.9%), respectively. The other hand, the unit loading factors of total phosphorus(T-P) for domestic waste water was 0.925g/capita, day, and that of gray and toilet waste water among the domestic waste water were 0.470g/capita, day(50.8%) and 0.455g/capita, day(49.2%), respectively. 3. In offering Price per million won, the T-P loading factor for drinking manufacture, confectionery manufacture, beer-manufacture and fibre manufacture in the industrial pollutant sources estimate to be 0.350g/day, 0.099g/day, 32.351g/day and 1.536g/day, while T-N loading factor about them in the industrial pollutant sources estimate to be 4.117g/day, 2.414g/day, 106.726g/day and 60.504g/day, respectively. 4. The T-P loading factor according to wash-water of milch cow and pig were 6.735g/day and 18.526g/day, in case of T-N they were 42.397g/day and 27.226g/day, respectively. 5. The T-P loading factor for pollutants drainage in the Paddy fields, fields and forests area were 0.082g/are, day, 0.014g/are, day and 0.002g/are, day, and the T-N loading factor were 0.309g/are, day, 0.158g/are, day and 0.064g/are, day, respectively. The diffrent of the loading factor for pollutants discharges in the agricultural area were resulted from the rainful intensity, the rainful, the amount of fertilization manure, and etc.

  • PDF