• Title/Summary/Keyword: uniformity test

Search Result 365, Processing Time 0.023 seconds

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • Diverging channel from gas engine exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B), two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of the boiler(Case C) and uniformity in velocity and temperature distribution has been improved considerably. Secondly, the diverging channel length can be further reduced to compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

An Integration Study of the Firing Test Stage at the Acceptance Test for the Propelling Charge (추진장약 수락시험의 시험단계 통합 연구)

  • Kim, Jaekab;Kim, Jaehoon;Na, Taeheum;Kim, Bokyun;Park, Noseok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • In this paper, the integration of the firing test stages at the acceptance test of the propelling charge has been studied using statistical analysis on the basis of the test data of K676 and K677 propelling charge for K9 self propelled howitzer. Acceptance test of K676 / K677 propelling charge consists of 3 stages and each stage is charge assessment test, charge uniformity test and charge proving ground test. Many of rounds are fired and much money is spent to prove the charge performance at each stage. The result of t-test shows that there is no difference between charge uniformity and charge proving ground test stage of K676 and K677 propelling charge.

Effect of a Suspended Overhead Sprayer with Sector Formed Injection Nozzles on Spraying Uniformity (두상관수장치의 부채꼴분사노즐 설치위치가 살수균일성에 미치는 영향)

  • 김명규;정태상;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.223-231
    • /
    • 1999
  • The one of basic functional conditions of suspended overhead sprayer, which is openly made use of irrigating on bedding plants in greenhouse, is to be kept the growing uniformity of bedding plants by making uniformly the spraying irrigation depending on the distribution of sprayed water. This study was performed to find out the optimum position of sector formed injection nozzle which is placed from the top of plant 0 the tip of the nozzle to keep spraying uniformity. The test of spraying distribution using a overhead sprayer, which was installed in a row of sector formed injection nozzles, was performed The measuring factor to represent spraying distribution was the water weight filled in each cup when the overhead sprayer was moving across the upside of the cups which were placed directly under the nozzles on keeping the distance from nozzle tip. The test results were as following , The standard mr of weights of each cup filled with spraying water was lower values at Position far from more than 60cm under nozzle tip. The driving speed variation of sprayer was not effected on spraying uniformity but the spraying water weight was inversely proportioned to the speed. To make best spraying uniformity, it was represented that the tip of the nozzle is positioned to keep the distance which the top of plants is placed at the second cross point of each injection sector of nozzles.

  • PDF

SLURRY UTILIZATION SYSTEM IN THE PADDY FIELD

  • I. H. Oh;Kim, K.D.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.784-791
    • /
    • 2000
  • To improve the uniformity of slurry spreading and to reduce the odor problem, a hose slurry spreader was developed, which spread the slurry near to the surface of the soil. First, the uniformity of slurry spreading was investigated. The best result of 8.1 % CV was obtained at the rotor speed of 250 rpm than any other speeds for the swine slurry, which contains 13.6% of dry matter. In case of dairy cattle slurry, which contains 8.2% of dry matter, the uniformity has the best result of CV 7.2% by high rotor speed of 330 rpm. A high speed of rotor has built a sufficient pressure in the distributor and discharged a uniform quantity of slurry through the hoses. Therefore, in practical use one should work with rotor speed over 300 rpm to maximize the uniformity of slurry spreading. Second, odor test was done with the swine slurry. While the conventional spreader shows ∑ value 440, the hose slurry spreader and its combination of disk harrow show ∑ value 258 and 184 respectively. With the air dilution sensual test and a 3-point odor bag, the conventional spreader shows 66.9 or 35.4 point and by the hose slurry spreader is 9.7 or 11.1 point. So, the developed spreader was found to have a greater effect on the reduction of odor problem. Finally, it is recommended to spread certain amount of the slurry for paddy field equivalent to the chemical fertilizer based on the N-content. It means 22 tons of swine slurry per ha. Since most of the livestock farms possess less arable land, a system of linking farms is necessary to utilize the slurry crossover the farms. The cost of slurry utilization including filling, transport spreading and brokerage is 3200-6800 Won/㎥ in accordance with the transport distance.

  • PDF

Electromagnetic Field Uniformity Characteristics of a Triangular Reverberation Chamber with Schroeder Diffusers (Schroeder 확산기를 적용한 삼각형 전자파 잔향실의 필드 균일도 특성)

  • 김성철;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.4
    • /
    • pp.373-378
    • /
    • 2002
  • This paper presents the results of an electromagnetic field uniformity of a triangular reverberation chamber that can be used alternatively for analysis and measurement of electromagnetic interference and immunity test. Equilateral triangular reverberation chamber and Schroeder diffusers were designed and fabricated for this purpose. FDTD simulation method was applied to analyze the field distribution inside of two different types of reverberation chambers. As a result, the electromagnetic field uniformity was improved inside of triangular reverberation chambers, and the measured field uniformity was improved by 1 ∼4 ㏈ compared to the ones without diffusers.

Relationship between ICAC EP-7 and %RMS, Standards for Gas Flow Uniformity inside Electrostatic Precipitators (전기집진기 내부 유동 균일도 평가 기준인 ICAC EP-7과 %RMS 간 상관관계)

  • Shin, Wan-Ho;Hong, Won-Seok;Song, Dong-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.234-240
    • /
    • 2010
  • Gas flow uniformity is an important factor to guarantee particle removal performance of electrostatic precipitators (EP), and the gas flow uniformity is evaluated by a fraction of standard deviation to the mean of gas flow distribution (%RMS) or a technical standard, ICAC EP-7, provided by The Institute of Clean Air Companies. In this study, relationship between the ICAC EP-7 and %RMS in evaluation of gas flow uniformity was investigated in terms of flow velocity. The maximum values of %RMS for gas velocity distribution of normal distribution has been obtained, and the maximum values of %RMS with gas velocity distribution satisfying ICAC EP-7 standards were also evaluated. With gas flow distribution obtained from CFD analysis and physical model test of real EP, %RMS values were calculated and it was tested if those gas flow distribution satisfy the criteria specified in ICAC EP-7. The %RMS values satisfying criteria of ICAC have been appeared to have similar values with %RMS values calculated with normal distribution of gas velocities.

Expansion of Test Frequency Band and Improvements of Field Uniformity in a Reverberation Chamber by Using Dual-Band Diffusers (이중 대역 확산기를 이용한 전자파 잔향실 시험 주파수 대역 확장 및 전자기장 균일도 향상에 관한 연구)

  • Lim Wook-Chae;Rhee Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.74-80
    • /
    • 2006
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber that can be used alternatively for the analysis, test and evaluation of electromagnetic interference and immunity. The dual-band diffuser, which can be used at two different frequency bands in a reverberation chamber, is applied, and it is made of two different single-band Schroeder's Quadratic Residue Diffusers. The FDTD method is used to analyze the field characteristics. Compared with single-band diffuser, the dual-band diffuser shows the improvement in not only expansion of test frequency band but also in characteristics of the field uniformity, polarity, power efficiency, and tolerance. Therefore, the reverberation chamber with the dual-band diffuser is a better facility, for the analysis and measurement of electromagnetic interference and immunity, than the reverberation chamber with a single-band diffuser.

CCD Non-uniformity Correction Method based on Pixel Non-Linearity Model (픽셀 비선형성 모델을 기반으로 한 영상센서 불균일 특성 보정)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • All pixels of image sensor do not react uniformly when the light of same radiance enters into the camera. This non-uniformity has a direct influence on the image quality. However we can overcome it by calibration process under the special test-setup. Usually it is used the algorithm to get the correction coefficients under the specific illumination condition. But, this method has drawback in the very low or very high illumination due to pixel non-linearity. This paper describes the robust algorithm, which calculates the correction coefficients based on the pixel non-linearity model, against thew hole radiance. The paper shows the non-uniformity test results with the own camera and the specified test equipments as well. The results shows the best performance over the entire radiance when this method is applied.

Numerical Analysis and Demonstration Test on the Performance of a Static Mixer for mixing Biogas and Town Gas for the 5MW Biogas Turbine (5MW 바이오가스 터빈의 바이오가스와 도시가스 혼합용 정적 혼합기의 성능에 관한 수치해석 및 실증 연구)

  • Cha, Hyoseok;Song, Soonho;Park, Jong Yeon;Kim, Young Il;Mun, Sung Young
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2015
  • The purpose of this study is to verify the performance of a static mixer for mixing of biogas and town gas by numerical analysis and demonstration test. The reason for designing a static mixer is that there is a need to mix town gas with biogas when there is less production of biogas in biogas sites. Non-uniformity in the outlet section was calculated for investigating the performance of a static mixer. Non-uniformity was based on the mole fraction of methane in a mixture of biogas and town gas. Low non-uniformity means that biogas and town gas are mixed well through this static mixer. Also, pressure drop at the outlet section of a static mixer was calculated. The pressure drop is less than 0.2% in this static mixer. This static mixer is suitable for applying to a 5MW bio-gas turbine through the demonstration test in the field.

Experimental Study of Heat Transfer in Vacuum Furnace (진공상태에서의 전열현상에 대한 실험적 연구)

  • Yang, Je-Bok;Kim, Won-Bae;Dong, Sang-Keun
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.109-113
    • /
    • 2003
  • Low pressure or vacuum carburizing(LPC) has undergone major further developments since 1980 and now it has achieved industrial maturity. The advantage of low pressure vacuum carburizing over gas carburizing is not only the creation of surface entirely free of oxide and environmentally friendly but also a reduction in batch times, lower gas and energy consumption and the prevention of soot. In this study the experiment was carried out to investigate the effects of vacuum atmosphere in the heating furnace. Heat transfer rate and uniformity of temperatures of test samples in the pressure range of a few 0.1torr was examined on a test charge of 100kg. It is found that the fuel saving rate due to decreasing heating time reach to 20% in the vacuum heating mode as compared with atmospheric heating mode. Also the uniformity of temperatures in the samples was improved significantly in the vacuum heating mode. Also the effects of the RC fan for stirring atmosphere inside furnace was examined. Results shows RC fan appears to provide a reasonable tool for improving uniformity of temperature in the atmospheric heating mode.

  • PDF