• Title/Summary/Keyword: uniform image

Search Result 647, Processing Time 0.028 seconds

Comparison of NDVI in Rice Paddy according to the Resolution of Optical Satellite Images (광학위성영상의 해상도에 따른 논지역의 정규식생지수 비교)

  • Jeong Eun;Sun-Hwa Kim;Jee-Eun Min
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1321-1330
    • /
    • 2023
  • Normalized Difference Vegetation Index (NDVI) is the most widely used remote sensing data in the agricultural field and is currently provided by most optical satellites. In particular, as high-resolution optical satellite images become available, the selection of optimal optical satellite images according to agricultural applications has become a very important issue. In this study, we aim to define the most optimal optical satellite image when monitoring NDVI in rice fields in Korea and derive the resolution-related requirements necessary for this. For this purpose, we compared and analyzed the spatial distribution and time series patterns of the Dangjin rice paddy in Korea from 2019 to 2022 using NDVI images from MOD13, Landsat-8, Sentinel-2A/B, and PlanetScope satellites, which are widely used around the world. Each data is provided with a spatial resolution of 3 m to 250 m and various periods, and the area of the spectral band used to calculate NDVI also has slight differences. As a result of the analysis, Landsat-8 showed the lowest NDVI value and had very low spatial variation. In comparison, the MOD13 NDVI image showed similar spatial distribution and time series patterns as the PlanetScope data but was affected by the area surrounding the rice field due to low spatial resolution. Sentinel-2A/B showed relatively low NDVI values due to the wide near-infrared band area, and this feature was especially noticeable in the early stages of growth. PlanetScope's NDVI provides detailed spatial variation and stable time series patterns, but considering its high purchase price, it is considered to be more useful in small field areas than in spatially uniform rice paddy. Accordingly, for rice field areas, 250 m MOD13 NDVI or 10 m Sentinel-2A/B are considered to be the most efficient, but high-resolution satellite images can be used to estimate detailed physical quantities of individual crops.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

Studies on the Drying Methods of Gangjung Pellets (강정 반데기 건조방법에 관한 연구)

  • 이승아;김창순;김혁일
    • Korean journal of food and cookery science
    • /
    • v.16 no.1
    • /
    • pp.47-56
    • /
    • 2000
  • The purpose of this study was to develop a drying method of Gangjung. a traditional Korean snack, thus to reduce the drying time and to improve the quality of Gangjung. Two drying methods, hot air drying and far infrared ray drying were used by changing conditions such as air velocity(0.4, 1.2, 1.6 m/s), temperature(40, 50, 60$\^{C}$), and aging. Optimal moisture content of dried Gangjung pellet was 17% which was proper for frying. Cracks appeared on the surface of Gangjung pellet at lower levels of moisture content. Far infrared ray drying saved drying time about 20%. Both hot air drying and far infrared ray drying at 0.4 m/s of air velocity tended to show better quality of Gangjung than those dried at higher air velocities. The expansion volume and texture of Gangjung drying at 40$\^{C}$ was better than other temperature conditions, regardless of drying methods. Quality of Gangjung, dried at single stage without aging, was superior to those dried at double stage including aging process. Moreover, single stage drying save the drying time at least 24 hr. Gangjung dried at high temperature became hard and less brittle in sensory evaluation. In image analysis, air cell distribution in inner structure of Gangjung became uniform and fine as drying temperature decreased to 40$\^{C}$. Overall, Gangjung made of Gangjung pellet by the use of far infrared ray drying at 40$\^{C}$ without aging, showed the best quality in terms of physical and sensory properties.

  • PDF

Fernand Khnopff's Belgian Symbolism and Nationalism in I Lock My Door upon Myself (페르낭 크노프(Fernand Khnopff)의 작품에 나타난 벨기에 상징주의와 내셔널리즘)

  • Chung, Y.-Shim
    • The Journal of Art Theory & Practice
    • /
    • no.9
    • /
    • pp.171-193
    • /
    • 2010
  • This paper examines Fernand Khnopff's Symbolism, focusing on the I Lock My Door upon Myself as a manifesto of his artistic credo in style and theme. Its title was originally in English, originating from the poem "Who Shall Deliver Me?" by Dante Gabriel Rossetti's sister Christina Rossetti. I use the term "Social Symbolism" which combines a nationalist perspective with traditional French Symbolism, in order to explain how the image of Bruges is represented in his oeuvre. Symbolism calls for psychological introspection evoking death, love, silence, and solitude and recluse from realty in pursuit of the Unknown and the Ideal. Although Khnopff shared this idea, he departed from symbolist tradition by incorporating a political milieu in his paintings. First, I discuss Khnopff's early stage in the formation of his artistic concept, including his family background as well as his early opportunity to visit the Exposition Universelle in Paris where he formed his early interests in aesthetics, philosophy, literature, mythology and Egyptian art. His early works, La Painture, la Musique, la Poesie(1880-1881), Le Crise(1881), and En ecoutant Schuman(1883) reveal his favorite subjects which were quite prevalent in the symbolist traditions of both Belgium and France. By looking at Khnopff's paintings, I endeavor to situate his Symbolism in the context of the development of Belgian modernity and cultural nationalism. Second, my analysis of Khnopff creates a new overview of Symbolism in Europe, especially in Belgium. In the absence of socio-political integration, the Symbolist painter adds nostalgic meaning to the landscape of Bruges. The scene of Bruges illuminates the social atmosphere in Belgium at that time. Since Belgium became an independent country, it tried to differentiate its own cultural and national identity from France. There was a powerful social movement for Belgium to claim its own identity, language, and culture. Bruges was, for Symbolists, the epitome of Belgium's past glory. This encouraged the formation of Belgian nationalism centering on Brussels, as I demonstrate in Khnopff's Bruges-la-Morte(1892). The relationship between Symbolist artist and writers is crucial for understanding this development. Khnopff, for instance, illustrated or provided frontispieces for many Symbolist writers such as Rodenbach, Peladan, Spencer and Le Roy. Khnopff did not objectify the exact meaning, but rather provided his own subjective interpretation. In this respect, I Lock My Door, inspired by Rossetti, started from the same motif, but Khnopff seeked escape into silence and death while Rossetti searched for Christian salvation. Finally my paper deals with the social context in which Khnopff worked. He was a founding member of Les XX in 1883 and later La Libre Esthethetique he also participated in the exhibition of le Salon de la Rose + Croix. Les XX was not a particular school of art and did not have a uniform manifesto, but its exhibitions focused on decorative arts by encompassing art for all people via common, everyday objects. The Periodical, L'art moderne was founded to support this ideal by Edmond Picard and Maux. Les XX declared art as independent art, detached from all official connections. Khnopff designed the 1890 catalogue cover of Les XX and the 1891 cover. These designs show decorative element of Art Nouveau in an early example of "modern poster." Les XX pursued all art including graphic arts, prints, placard, posters and book illustrations and design. These forms of art were l'art social and this movement was formed by the social atmosphere in Belgium in terms of social reforms and strikes by working class. Khnopff designed the book cover for la Maison du Peuple. The artist, however, did not share the ideal egalitarianism of the working class to a certain degree, while he was working in his villa he designed under the ideal motto, "on n'a pas que," he expressed the nihilistic emotions toward society by the theme of interiority such as solitude, silence, narcissism, introspection, and introversion. In the middle of his Symbolism, we find the "cultural nostalgia" or longing that the artist develops in the I Lock My Door upon Myself. Khnopff's longing toward the lost city of "Bruges" form the crux of his "Social Symbolism."

  • PDF

Estimation of Paddy Field Area in North Korea Using RapidEye Images (RapidEye 영상을 이용한 북한의 논 면적 산정)

  • Hong, Suk Young;Min, Byoung-Keol;Lee, Jee-Min;Kim, Yihyun;Lee, Kyungdo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1194-1202
    • /
    • 2012
  • Remotely sensed satellite images can be applied to monitor and obtain land surface information on inaccessible areas. We classified paddy field area in North Korea based on on-screen digitization with visual interpretation using 291 RapidEye satellite images covering the whole country. Criteria for paddy field classification based on RapidEye imagery acquired at different time of rice growth period was defined. Darker colored fields with regular shape in the images with false color composite from early May to late June were detected as rice fields. From early July to late September, it was hard to discriminate rice canopy from other type of vegetation including upland crops, grass, and forest in the image. Regular form of readjusted rice field in the plains and uniform texture when compared with surrounding vegetation. Paddy fields classified from RapidEye imagery were mapped and the areas were calculated by administrative district, province or city. Sixty six percent of paddy fields ($3,521km^2$) were distributed in the west coastal regions including Pyeongannam-do, Pyeonganbuk-do, and Hwanghaenam-do. The paddy field areas classified from RapidEye images showed less than 1% of difference from the paddy field areas of North Korea reported by FAO/WFP (Food and Agriculture Organization/World Food Programme).

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Study of Motion Effects in Cartesian and Spiral Parallel MRI Using Computer Simulation (컴퓨터 시뮬레이션을 이용한 직각좌표 및 나선주사 방식의 병렬 자기공명 영상에서 움직임 효과 연구)

  • Park, Sue-Kyeong;Ahn, Chang-Beom;Sim, Dong-Gyu;Park, Ho-Chong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Purpose : Motion effects in parallel magnetic resonance imaging (MRI) are investigated. Parallel MRI is known to be robust to motion due to its reduced acquisition time. However, if there are some involuntary motions such as heart or respiratory motions involved during the acquisition of the parallel MRI, motion artifacts would be even worse than those in conventional (non-parallel) MRI. In this paper, we defined several types of motions, and their effects in parallel MRI are investigated in comparisons with conventional MRI. Materials and Methods : In order to investigate motion effects in parallel MRI, 5 types of motions are considered. Type-1 and 2 are periodic motions with different amplitudes and periods. Type-3 and 4 are segment-based linear motions, where they are stationary during the segment. Type-5 is a uniform random motion. For the simulation, Cartesian and spiral grid based parallel and non-parallel (conventional) MRI are used. Results : Based on the motions defined, moving artifacts in the parallel and non-parallel MRI are investigated. From the simulation, non-parallel MRI shows smaller root mean square error (RMSE) values than the parallel MRI for the periodic (type-1 and 2) motions. Parallel MRI shows less motion artifacts for linear(type-3 and 4) motions where motions are reduced with shorter acquisition time. Similar motion artifacts are observed for the random motion (type-5). Conclusion : In this paper, we simulate the motion effects in parallel MRI. Parallel MRI is effective in the reduction of motion artifacts when motion is reduced by the shorter acquisition time. However, conventional MRI shows better image quality than the parallel MRI when fast periodic motions are involved.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF