• Title/Summary/Keyword: uniform ideal

Search Result 86, Processing Time 0.018 seconds

The Role of MMA and EGDMA in Enhancing the Mechanical Properties of PMMA Composites (PMMA 복합재의 기계적 특성 향상을 위한 MMA 및 EGDMA의 역할 연구)

  • Aqila Che Ab Rahman;Shiyoung Yang;Sooman lim
    • Journal of Integrative Natural Science
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2024
  • This study explores the enhancement of mechanical properties in Polymethyl Methacrylate (PMMA) composites through the incorporation of Methyl Methacrylate (MMA) and Ethylene Glycol Dimethacrylate (EGDMA). Utilizing Digital Light Processing (DLP) technology, we conducted a series of experiments to analyze the impact of varying concentrations of MMA and EGDMA on PMMA. The results indicate that while MMA demonstrates non-linear and variable mechanical strength across different PMMA concentrations, EGDMA consistently improves mechanical strength as PMMA concentration increases. This consistent enhancement by EGDMA suggests a stable and predictable reinforcement effect, which is critical for applications requiring high mechanical strength. Our comparative analysis highlights that EGDMA is a more effective additive than MMA for optimizing the mechanical performance of PMMA composites. Specifically, EGDMA's ability to provide uniform reinforcement across various PMMA concentrations makes it ideal for high-strength applications. These findings are significant for material scientists and engineers focused on the design and development of advanced PMMA-based materials. In conclusion, this research underscores the importance of selecting appropriate additives to enhance the mechanical properties of PMMA composites. The superior performance of EGDMA in reinforcing PMMA suggests its potential for broader applications in fields such as automotive, construction, medical devices, and 3D printing. This study provides valuable insights that can guide future research and development in high-performance composite materials, paving the way for innovative applications and improved material efficiency.

Solvothermal Synthesis and Characterization of Cu3(BTC)2 Tubular Membranes Using Surface Modified Supports (표면 개질된 지지체를 이용한 Cu3(BTC)2 튜브형 분리막의 용매열 합성 및 특성분석)

  • Noh, Seung-Jun;Kim, Jinsoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.214-218
    • /
    • 2014
  • In this study, nanoporous $Cu_3(BTC)_2$ membranes were synthesized on macroporous alumina tube supports by solvothermal method. It is very difficult to prepare uniform and crack-free $Cu_3(BTC)_2$ layer on macroporous alumina support by in situ solvothermal method. In this study, continuous and crack-free $Cu_3(BTC)_2$ tubular membranes could be obtained by in situ solvothermal process after surface modification of alumina support. The surface modification was conducted by spraying Cu precursor solution on the alumina support heated at $200^{\circ}C$. The prepared $Cu_3(BTC)_2$ tubular membranes were characterized by XRD, FE-SEM and gas permeation experiments. $H_2$ permeance through $5{\mu}m$ thick $Cu_3(BTC)_2$ tubular membrane was calculated to be $7.8{\times}10^{-7}mol/s{\cdot}m^2{\cdot}Pa$ by single gas permeation test, with the ideal selectivities of $H_2/N_2=11.94$, and $H_2/CO_2=12.82$.

Effect of LED light on the inactivation of Bacillus cereus for extending shelf-life of extruded rice cake and simulation of the patterns of LED irradiation by various arrays of LEDs (압출떡의 유통기한 연장을 위한 LED 조사의 Bacillus cereus 억제 효과 및 LED의 배열에 따른 빛의 조사 패턴 시뮬레이션)

  • Jung, Hwabin;Yuk, Hyun-Gyun;Yoon, Won Byong
    • Journal of Applied Biological Chemistry
    • /
    • v.62 no.2
    • /
    • pp.181-186
    • /
    • 2019
  • The optimum design of LED device for irradiation of 460 nm blue light on extruded rice cake using simulation and the effect of the blue light on the inactivation of Bacillus cereus (B. cereus) group on the rice cake were investigated. The irradiated light intensity patterns on the surface area of the sample were simulated with three different LED arrays (centered, cross, and evenly spaced) and at various distances (22, 32, 42 mm) between the LED modules and the sample. In addition, the uniformity was calculated as Petri factor. The evenly spaced array resulted the most uniform light intensity pattern in the simulation, and the Petri factor of 32 and 42 mm of the distances showed higher than 0.9, which represents the ideal uniformity of LED device. The bacterial population of the rice cake decreased to less than the initial bacterial population during exposure to LED blue light, whereas the bacterial population of the control sample increased. The bacterial count of the rice cake after blue light irradiation for 24 h was 1.21 log CFU/g lower than the control sample. Petri factor increased with increase of the distance between the light source and sample, however, the reduction rate of B. cereus group decreased. Therefore, the design of LED device, that represented the Petri factor higher than 0.9 and inactivated the population of B. cereus group, with evenly spaced and 32 mm of distance between the light source and sample was suitable for extending shelf-life of rice cake.

Effect of Monascus purpureus-Fermented Korean Red Ginseng Powder on the Serum Lipid Levels and Antioxidative Activity in Rats (홍국발효홍삼 분말 급여에 의한 흰쥐의 혈청 지질 농도 및 항산화 활성에 미치는 영향)

  • Cha, Jae-Young;Park, Jin-Chul;Ahn, Hee-Young;Eom, Kyung-Eun;Park, Bo-Kyung;Jun, Bang-Sil;Lee, Chi-Hyeong;Cho, Young-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1153-1160
    • /
    • 2009
  • Monascus-fermented Korean red ginseng (MFRG), fermented by Monascus purpureus KCCM 12002, may be an ideal candidate for the hepatoprotectic, hypolipidemic and antioxidative activities. Effect of MFRG powder on these parameters in rats was investigated. Body weight gain, food intake, and water consumption were not significantly different among the groups. Total and relative weights of liver were significantly higher in MFRG group than that in other groups. The activities of AST and $\gamma$-GTP were highly lowered in MFRG group compared to control group. Contents of serum total lipid and triglyceride were significantly lowered in silymarin group and were significantly increased in MFRG group compared to control group, but tended to be lowered in RG group. Serum content of total cholesterol tended to be lowered in silymarin, RG, and MFRG groups compared to control group. HDL-cholesterol contents was only significantly increased in MFRG group compared to control group. At the same time, atherogenic index (AI) was also significantly lowered in silymarin, RG and MFRG groups compared to control group, and this effect was more pronounced in MFRG group. Content of thiobarbituric acid reactive substances (TBARS) in the liver was significantly lowered in MFRG group and tended to lowered in silymarin and RG groups compared to control group. The hepatic glutathione concentration was significantly higher in silymarin and MFRG groups. Hepatic morphology in all experimental groups revealed clear-cut hepatic lobules with the uniform pattern of the polyhedral hepatocytes radiating towards the periphery from the central vein. These results suggested that MFRG may have anti-atherogenic index (AI) and antioxidative activity in normal dietary feeding rats.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.