• Title/Summary/Keyword: uniform dose

Search Result 109, Processing Time 0.026 seconds

A Dose Volume Histogram Analyzer Program for External Beam Radiotherapy (방사선치료 관련 연구를 위한 선량 체적 히스토그램 분석 프로그램 개발)

  • Kim, Jin-Sung;Yoon, Myong-Geun;Park, Sung-Yong;Shin, Jung-Suk;Shin, Eun-Hyuk;Ju, Sang-Gyu;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.240-248
    • /
    • 2009
  • Purpose: To provide a simple research tool that may be used to analyze a dose volume histogram from different radiation therapy planning systems for NTCP (Normal Tissue Complication Probability), OED (Organ Equivalent Dose) and so on. Materials and Metohds: A high-level computing language was chosen to implement Niemierko's EUD, Lyman-Kutcher-Burman model's NTCP, and OED. The requirements for treatment planning analysis were defined and the procedure, using a developed GUI based program, was described with figures. The calculated data, including volume at a dose, dose at a volume, EUD, and NTCP were evaluated by a commercial radiation therapy planning system, Pinnacle (Philips, Madison, WI, USA) for comparison. Results: The volume at a special dose and a dose absorbed in a volume on a dose volume histogram were successfully extracted using DVH data of several radiation planning systems. EUD, NTCP and OED were successfully calculated using DVH data and some required parameters in the literature. Conclusion: A simple DVH analyzer program was developed and has proven to be a useful research tool for radiation therapy.

Evaluation of Surface Dose for Field-in-Field (FIF) Technique in Breast Radiotherapy (유방암 방사선치료에서 Field-in-Field (FIF) 기법의 조사면 주변 선량 분석)

  • Il-Hoon, Cho;Daehong, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.851-856
    • /
    • 2022
  • The purpose of this study is to confirm the effect of reducing the surface dose around the radiation field in breast cancer radiotherapy using the Field-in-Field (FIF) technique. X-ray was exposed from a linear accelerator (Linac) was used for irradiation, and the surface dose was measured with a glass dosimeter. The source-to-surface distance (SSD) was 90 cm, the field size is 10 × 10 cm2, and the X-ray energy was 6 MV and 10 MV, respectively. The surface dose of the FIF was compared with the dose measured in the physical wedge (PW) and dynamic wedge (DW). Wedge angles of 15° and 30° were used in the PW and DW, respectively. Surface dose was measured at 1 cm, 3 cm, and 5 cm from the center of the field size, respectively. According to the results, FIF showed lower surface dose compared to PW and DW regardless of the energy of the X-ray beam, wedge angle, and dose measurement point. Since FIF could reduce the radiation dose in periphery of the field size in breast cancer treatment, it is expected to be able to reduce the secondary damage caused by the radiation beam as well as to obtain a uniform dose distribution on the target.

Clinical Application of 3-D Compensator in Head and Neck Cancer (두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰)

  • Hong, Dong-Ki;Lee, Jeong-Woo;Lee, Koo-Hyun;Park, Kwang-Ho;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Kang, SungHee;Cho, Jin Dong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.39-44
    • /
    • 2017
  • This study aims to analyze dose distribution and treatment time of endobronchial brachytherapy (EBBT) by changing the position step size of the dwell position. A solid water phantom and an intraluminal catheter were used in the treatment plan. The treatment plans were generated for 3, 5, 7, and 10 cm treatment lengths, respectively. For each treatment length, the source position step sizes were set as 2.5, 5, and 10 mm. Three reference points were set 1 cm away from the central axis of the catheter, along the axis, for uniform dose distribution. Volumetric dose distribution was calculated to evaluate the dosimetric effect. The total radiation delivery time and total dwell time were estimated for treatment efficiency, which were increased with position step sizes. At half-life time, the differences between the position step sizes in the total radiation delivery time were 18.1, 15.4, 18.0, and 24.0 s for 3, 5, 7, and 10 cm treatment lengths, respectively. The dose distributions were more homogenous by increasing the position step sizes. The dose difference of the reference point was less than 10%. In brachytherapy, this difference can be negligible. For EBBT, the treatment time is the key factor while considering the patient status. To reduce the total treatment time, EBBT can be performed with 2.5 mm position step size.

Comparing the performance of two hybrid deterministic/Monte Carlo transport codes in shielding calculations of a spent fuel storage cask

  • Lai, Po-Chen;Huang, Yu-Shiang;Sheu, Rong-Jiun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2018-2025
    • /
    • 2019
  • This study systematically compared two hybrid deterministic/Monte Carlo transport codes, ADVANTG/MCNP and MAVRIC, in solving a difficult shielding problem for a real-world spent fuel storage cask. Both hybrid codes were developed based on the consistent adjoint driven importance sampling (CADIS) methodology but with different implementations. The dose rate distributions on the cask surface were of primary interest and their predicted results were compared with each other and with a straightforward MCNP calculation as a baseline case. Forward-Weighted CADIS was applied for optimization toward uniform statistical uncertainties for all tallies on the cask surface. Both ADVANTG/MCNP and MAVRIC achieved substantial improvements in overall computational efficiencies, especially for gamma-ray transport. Compared with the continuous-energy ADVANTG/MCNP calculations, the coarse-group MAVRIC calculations underestimated the neutron dose rates on the cask's side surface by an approximate factor of two and slightly overestimated the dose rates on the cask's top and side surfaces for fuel gamma and hardware gamma sources because of the impact of multigroup approximation. The fine-group MAVRIC calculations improved to a certain extent and the addition of continuous-energy treatment to the Monte Carlo code in the latest MAVRIC sequence greatly reduced these discrepancies. For the two continuous-energy calculations of ADVANTG/MCNP and MAVRIC, a remaining difference of approximately 30% between the neutron dose rates on the cask's side surface resulted from inconsistent use of thermal scattering treatment of hydrogen in concrete.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

A Monte Carlo Simulation Study of a Therapeutic Proton Beam Delivery System Using the Geant4 Code (Geant4 몬테카를로 코드를 이용한 양성자 치료기 노즐의 전산모사)

  • Shin, Jungwook;Shim, Hyunha;Kwak, Jungwon;Kim, Dongwook;Park, Sungyong;Cho, Kwan Ho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.226-232
    • /
    • 2007
  • We studied a Monte Carlo simulation of the proton beam delivery system at the National Cancer Center (NCC) using the Geant4 Monte Carlo toolkit and tested its feasibility as a dose verification framework. The Monte Carlo technique for dose calculation methodology has been recognized as the most accurate way for understanding the dose distribution in given materials. In order to take advantage of this methodology for application to external-beam radiotherapy, a precise modeling of the nozzle elements along with the beam delivery path and correct initial beam characteristics are mandatory. Among three different treatment modes, double/single-scattering, uniform scanning and pencil beam scanning, we have modeled and simulated the double-scattering mode for the nozzle elements, including all components and varying the time and space with the Geant4.8.2 Monte Carlo code. We have obtained simulation data that showed an excellent correlation to the measured dose distributions at a specific treatment depth. We successfully set up the Monte Carlo simulation platform for the NCC proton therapy facility. It can be adapted to the precise dosimetry for therapeutic proton beam use at the NCC. Additional Monte Carlo work for the full proton beam energy range can be performed.

  • PDF

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay (토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석)

  • Song, Ju-Young;Jung, Jae-Uk;Yoon, Mee-Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.178-183
    • /
    • 2011
  • The applicability and feasibility of TomoTherapy in the lung radiation surgery was analyzed by comparison of the calculated dose distribution in TomoTherapy planning with the results of conventional IMRS (intensity modulated radiation surgery) using LINAC (linear accelerator). The acquired CT (computed tomograph) images of total 10 patients whose tumors' motion were less than 5 mm were used in the radiation surgery planning and the same prescribed dose and the same dose constraints were used between TomoTherapy and LINAC. The results of TomoTherapy planning fulfilled the dose requirement in GTV (gross tumor volume) and OAR (organ at risk) in the same with the conventional IMRS using LINAC. TomoTherapy was superior in the view point of low dose in the normal lung tissue and conventional LINAC was superior in the dose homogeneity in GTV. The calculated time for treatment beam delivery was long more than two times in TomoTherapy compared with the conventional LINAC. Based on the results in this study, TomoTherapy can be evaluated as an effective way of lung radiation surgery for the patients whose tumor motion is little when the optimal planning is produced considering patient's condition and suitability of dose distribution.