• 제목/요약/키워드: uniform current

검색결과 1,026건 처리시간 0.027초

A Fully Optimized Electrowinning Cell for Achieving a Uniform Current Distribution at Electrodes Utilizing Sampling-Based Sensitivity Approach

  • Choi, Nak-Sun;Kim, Dong-Wook;Cho, Jeonghun;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.641-646
    • /
    • 2015
  • In this paper, a zinc electrowinning cell is fully optimized to achieve a uniform current distribution at electrode surfaces. To effectively deal with an electromagnetically coupled problem with multi-dimensional design variables, a sampling-based sensitivity approach is combined with a highly tuned multiphysics simulation model. The model involves the interrelation between electrochemical reactions and electromagnetic phenomena so as to predict accurate current distributions in the electrowinning cell. In the sampling-based sensitivity approach, Kriging-based surrogate models are generated in a local window, and accordingly their sensitivity values are extracted. Such unique design strategy facilitates optimizing very complicated multiphysics and multi-dimensional design problems. Finally, ten design variables deciding the electrolytic cell structure are optimized, and then the uniformity of current distribution in the optimized cell is examined through the comparison with existing cell designs.

An a-D film for flat panel displays prepared by FAD

  • Liu, Xianghuai;Mao, Dongsheng
    • 한국진공학회지
    • /
    • 제7권s1호
    • /
    • pp.7-14
    • /
    • 1998
  • Details are given of an study of the characteristics of field-induced electron emission from hydrogen-free high $sp^3$ content(>90%) amorphous diamond (a-D) film deposited on heavily doped ($\rho$<0.01 $\Omega\cdot\textrm{cm}$) n-type monocrystalline Si(111) substrate. It is demonstrated that a-D film has excellent electron field emission properties. Emission current can reach 0.9 $\mu$A at applied field as low as 1 V/$\mu\textrm{m}$, and emission current density can be obtained about several mA/$\textrm{cm}^2$. The emission current is stable when the beginning current is at 50 $\mu$A within 72 hours. Uniform fluorescence display of electron emission from whole face of the a-D film under the electric field of 10~20 V/$\mu\textrm{m}$ was also observed. It can be considered that the contribution of excellent electron emission property results from its smooth, uniform, amorphous surface and high $sp^3$ content of the a-D films.

  • PDF

불균일 전류분포가 Bi-2223/Ag 초전도선재의 통전손실에 미치는 영향 (Influence of non-uniform current distribution on transport ac loss in Bi-2223/Ag tapes)

  • 최세용;나완수;주진호;김정호;류경우;손명환;권영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1240-1242
    • /
    • 2005
  • In this study, we estimate the transport current loss of Bi-2223/Ag tapes with non-uniform current distribution. The conductor was consisted of three Bi-2223/Ag tapes and the each tapes were attached in parallel. The loss of conductor was investigated both numerical and experimental methods. The numerical code to predict ac loss was developed, and finite element method was introduced. It contained intrinsic properties of superconducting tape, which was obtained from nonlinear current voltage relation with external magnetic field and its orientation. Two results were compared and discussed. They showed good agreements with each other.

  • PDF

신형 태권도 공인도복의 전통성 제언 및 디자인 수정 제안 (Endowment of Traditionality to the New Style Taekwondo Uniform and a Proposal of Its Design Modification)

  • 최연우
    • 한국의류학회지
    • /
    • 제38권1호
    • /
    • pp.19-32
    • /
    • 2014
  • The Taekwondo uniform has remained consistent since it was officially designed in a V-neck form in 1976. Taekwondo is a martial art that emphasizes social etiquette; therefore, it is necessary to dress in a uniform that reflects Korean traditions and ancient oriental philosophy. However, the current official uniform has limitations in endowing traditionality and many usability problems. Thus, recognizing the problems raised with the uniform, the Kukkiwon (World Taekwondo Headquarters) developed a new style official uniform in 2011. This study is to endow traditional meaning to a new style uniform and proposes some design modifications that can convey a more traditional adequacy. The development of the new official uniform began with a specific plan for change from the existing uniform, this study as subsequent work is significant in that its endowment of symbolism and modification proposal is for the actual execution and global dissemination of traditional Taekwondo culture. The results of this study are as follows. First, we can endow Korea's traditional historicity and symbolism to the new uniform in form and colors. All contents of the design (in which the front side is open, the top is adjusted rightward, the rear length is shorter than the front length, comfort provided by side vents, dual collars for children's uniforms, and a belt) are adapted from the Korean traditional costume. Consequently, historicity can be endowed to the uniform. It is also confirmed that the traditional oriental philosophy including heaven and earth (天地), Yin-Yang (陰陽), and Five Elements (五行) can be endowed in the use of colors. Second, in order to project deeper historicity and symbolism to the form of the new uniform, this study proposes design modifications based on the selection as an item of Simui (深衣), a type of traditional clothing that contains a high symbolism similar to the Taekwondo uniform. It proposes giving shape to the practice of manners, the righteous life, and the straightforward mind by modifying the design of the uniform in the fish belly part of the sleeves, collars, back stitches, and side seams.

A Study on the Changes of the Women's Uniform in England

  • Kim, Kyung-Hee
    • 패션비즈니스
    • /
    • 제6권3호
    • /
    • pp.15-27
    • /
    • 2002
  • A uniform is generated in the course of confirming a singular mode of dress that is adopted by a community for a specific purpose. In particular, women's uniform has a close relations to their position in the community they belong to. And women's uniform has closely been associated with finding ways into their communities over the centuries, and is part of women's development process. Women's history of using organized uniforms has not been longer than men's. Their realm of activities began to be enlarged due to the World War, and women's uniform has gradually settled down and moved toward diversity. The origin of many uniforms worn by today's women can be traced back to the end of the last century, and this fact indicates that women started to find their ways into many new fields at that time. There has been a lot of changes until current women's uniforms come out. It's intended in this study to contribute to designing more creative and productive women's uniform, by taking a careful look at typical early uniforms for service personnels, nannies, nurses and soldiers that are an indication of their work and working environment.

금선 히터가 있는 금/YBCO 박막 선에서의 퀜치 분포 (Quench Distribution in AU/YBCO Thin Film Meander Lines with a Au Meander Line Heater)

  • Kim, H. R.;J. W. Shim;O. B. Hyun;J. M. Oh
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.118-123
    • /
    • 2004
  • We investigated quench distribution in AU/YBCO thin film meander lines with a heater. Quench distribution during faults is important for superconducting fault current limter applications, because uniform quench allows application of higher voltages across the meander lines. AU/YBCO thin films grown on sapphire substrates were patterned into meander lines by photolithography. Gold films grown on the rear sides of the substrates were also patterned into meander lines, and used as heaters. Meander lines on the front and the rear sides were connected in parallel. The meander lines were subjected to simulated AC fault currents for quench measurements during faults. They were immersed in liquid nitrogen during the experiment for effective cooling. Resistance of the AU/YBCO meander lines initially increased more rapidly with the rear heater than without, and consequently the fault current was limited more. The resistance subsequently became similar, The resistance distribution was more uniform with the heater, especially during the initial quench. Quench was completed more uniformly and significantly earlier. This resulted in uniform distribution of dissipated power. These results could be explained with the concept of quench propagation, which was accelerated by heat transfer across the substrate from the rear heater.

  • PDF

한국 남자 군인 기능성 방한복 내피 개발을 위한 실태 및 만족도 조사 (A Survey on Actual Wearing Condition and Satisfaction of Functional Inner Winter Uniform for Male Soldiers in Korea)

  • 김연주;김선영
    • 한국의류학회지
    • /
    • 제46권5호
    • /
    • pp.910-926
    • /
    • 2022
  • Suitability for the human body, freedom to move and thermal insulation are important design considerations in military clothing. This study investigates the performance and wearer-satisfaction of the functional inner winter uniform currently used in Korea; it is hoped that our data can inform the development of a future version. Interviews were conducted, in which the participants suggested various improvements. The uniforms were mainly worn for guard duty or as daily attire in cold weather. The participants chose how many layers to wear according to the current situation, rather than sticking to the layering recommended in the manual. Layering choices did not significantly affect combat efficiency but were found to affect wearers' comfort. Wearers' satisfaction was found to depend on the convenience of the clothing, whether it was in the appropriate size, freedom to move and thermal insulation. Also, this study suggests a problem with the current size system, as the analysis of size distribution, across all sizes, the range of current production is insufficient to cover the demand.

직렬 배치된 두 부유체에 작용하는 조류력 및 풍력 특성에 관한 수치해석 연구 (Numerical Study of Current and Wind Forces Acting on Two Floating Bodies in Tandem Configuration)

  • 홍장표;남보우;윤경원;김영식;성홍근
    • 한국해양공학회지
    • /
    • 제28권5호
    • /
    • pp.378-386
    • /
    • 2014
  • In this study, the characteristics of the current and wind forces acting on two floating bodies were numerically investigated using a commercial CFD software, STAR-CCM+. In the numerical analyses, LNGC was located right behind FSRU under uniform current or wind conditions. Steady calculations were carried out using a Reynolds averaged Navier-Stokes (RANS) solver and the realized k-epsilon model. First, the current coefficients of FSRU based only the CFD were compared with the model test data. Through this comparison, the present numerical models and mesh systems were indirectly verified. Next, computations for FSRU and LNGC in a uniform current were performed using different relative positions. It was found that the current coefficients were great affected by the longitudinal positions. Finally, the wind forces acting on FSRU and LNGC in tandem configurations were studied. The focus was on the shielding effects due to the aerodynamic interactions between FSRU and LNGC.

Investigation of I-V characteristics and heat generation of multiply connected HTS conductors in parallel

  • Park, H.C.;Kim, S.;Cho, J.;Sohn, M.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.20-23
    • /
    • 2012
  • With continuous development of the 2nd generation HTS conductor, the critical current of the conductor is also increasing. However, many applications require more than 2 conductors in parallel to transport large current. Applications such as HTS power cables and some HTS current leads usually need much larger transport current than that provided by a single conductor and they require more than several tens of HTS conductors. In the case of parallel connection of multiple HTS conductors, the current distribution depends on the contact resistance of each conductor at the terminals for DC operation. The non-uniform distribution of the terminal resistances results in a non-uniform distribution of the current. The resultant current non-uniformity affects on the measurement of the I-V curve and the thermal performance of the multiple conductors. This paper describes the I-V curves obtained from multiply connected HTS conductors with different terminal contact resistances to investigate the relationship between the distorted I-V curve and heat generation.

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.