• Title/Summary/Keyword: underground stories

Search Result 24, Processing Time 0.019 seconds

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

How Phenolic Composites were chosen - In Case of England (6) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 6))

  • Nomaguchi, Kanemasa;Forsdyke, Ken L
    • Composites Research
    • /
    • v.17 no.6
    • /
    • pp.58-66
    • /
    • 2004
  • As the first modem industrialized country in the world, so England UK was safetyfied from "SMOKE FIRE DANCER" at London Underground as the first country also. Indeed, the quick decision maker of Grate London Metropolitan must be serious, while the technology developing people also so eager in rebuilding safer composite system for public security accumulating basic data at their laboratories. Mr. Ken L. Forsdyke, one of co-authors of this paper, who was the project leader at BP Chemicals International Company at that time, is now telling you some key points adding to the stories he mentioned before in this series, "How Phenolic Composites were chosen". Now, with another article of the basic data, our tales of "In Case England" will be closed. May God save people from "Horror SMOKE FIRE".ople from "Horror SMOKE FIRE".IRE&".ot;.

A Case Study of Blast Demolition at Chung-Ang Department Store in Daejeon City (대전 중앙데파트 발파해체 사례)

  • Min, Hyung-Dong;Park, Jong-Ho;Song, Young-Suk;Park, Hoon
    • Explosives and Blasting
    • /
    • v.27 no.1
    • /
    • pp.62-78
    • /
    • 2009
  • Recently, construction techniques have been rapidly developed with reconstruction of old buildings, urban regeneration and efforts of restoring natural ecology, so demolition of deteriorated buildings has been rapidly increasing. Demolition work of building should be executed without damaging surrounding environments according to relevant regulations. There are various demolition methods and among them, explosives demolition is the most practical way for expenses and safety of work. As a part of Daejeon stream ecological restoration project, this thesis is a case of executing demolition of Chung-Ang Department Store which was built 35 years ago as covered structure on the upper part of Daejeon stream with explosives demolition. This structure is 8 stories high, total height of 41.6 m including basement floor, $1,650m^2$ for building area and $18,351m^2$ for total floor area. It is located in the center of Daejeon city where shopping centers and buildings are crowded and main facilities are Daejeon subway (18m), backside shopping center (20m), underground shopping center(15m), Mokchuk bridge, Eunjung bridge(0.25m) and fiber-optic cable(0.25m). In this project, implosion was selected for explosives demolition methods by considering this area being a busy urban area, and this project was executed after examining collapse movement of structure in advance using simulation program not to damage main facilities. Total 80kg of explosives and 1,000 detonators were being used. This project will be a good case of executing explosives demolition successfully by applying implosion on urban area in the country.

A Study on the Improvement Plans of Police Fire Investigation (경찰화재조사의 개선방안에 관한 연구)

  • SeoMoon, Su-Cheol
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.103-121
    • /
    • 2006
  • We are living in more comfortable circumstances with the social developments and the improvement of the standard of living, but, on the other hand, we are exposed to an increase of the occurrences of tires on account of large-sized, higher stories, deeper underground building and the use of various energy resources. The materials of the floor in a residence modern society have been going through various alterations in accordance with the uses of a residence and are now used as final goods in interioring the bottom of apartments, houses and shops. There are so many kinds of materials you usually come in contact with, but in the first place, we need to make an experiment on the spread of the fire with the hypocaust used as the floors of apartments, etc. and the floor covers you usually can get easily. We, scientific investigators, can get in contact with the accidents caused by incendiarism or an accidental fire closely connected with petroleum stuffs on the floor materials that give rise to lots of problems. on this account, I'd like to propose that we conduct an experiment on fire shapes by each petroleum stuff and that discriminate an accidental tire from incendiarism. In an investigation, it seems that finding a live coal could be an essential part of clearing up the cause of a tire but it could not be the cause of a fire itself. And besides, all sorts of tire cases or fire accidents have some kind of legislation and standard to minimize and at an early stage cope with the damage by tires. That is to say, we are supposed to install each kind of electric apparatus, automatic alarm equipment, automatic fire extinguisher in order to protect ourselves from the danger of fires and check them at any time and also escape urgently in case of fire-outbreaking or build a tire-proof construction to prevent flames from proliferating to the neighboring areas. Namely, you should take several factors into consideration to investigate a cause of a case or an accident related to fire. That means it's not in reason for one investigator or one investigative team to make clear of the starting part and the cause of a tire. accordingly, in this thesis, explanations would be given set limits to the judgement and verification on the cause of a fire and the concrete tire-spreading part through investigation on the very spot that a fire broke out. The fire-discernment would also be focused on the early stage fire-spreading part fire-outbreaking resources, and I think the realities of police tire investigations and the problems are still a matter of debate. The cause of a fire must be examined into by logical judgement on the basis of abundant scientific knowledge and experience covering the whole of fire phenomena. The judgement of the cause should be made with fire-spreading situation at the spot as the central figure and in case of verifying, you are supposed to prove by the situational proof from the traces of the tire-spreading to the fire-outbreaking sources. The causal relation on a fire-outbreak should not be proved by arbitrary opinion far from concrete facts, and also there is much chance of making mistakes if you draw deduction from a coincidence. It is absolutely necessary you observe in an objective attitude and grasp the situation of a tire in the investigation of the cause. Having a look at the spot with a prejudice is not allowed. The source of tire-outbreak itself is likely to be considered as the cause of a tire and that makes us doubt about the results according to interests of the independent investigators. So to speak, they set about investigations, the police investigation in the hope of it not being incendiarism, the fire department in the hope of it not being problems in installments or equipments, insurance companies in the hope of it being any incendiarism, electric fields in the hope of it not being electric defects, the gas-related in the hope of it not being gas problems. You could not look forward to more fair investigation and break off their misgivings. It is because the firing source itself is known as the cause of a fire and civil or criminal responsibilities are respected to the firing source itself. On this occasion, investigating the cause of a fire should be conducted with research, investigation, emotion independent, and finally you should clear up the cause with the results put together.

  • PDF