• Title/Summary/Keyword: underground spaces

Search Result 198, Processing Time 0.024 seconds

A Study on the Suitability of Characteristics for Planning of Exterior Pedestrian Spaces in Large-scale Apartment Complexes (대규모 아파트단지 외부보행공간의 계획특성에 관한 적합성 평가 연구)

  • Kwon, So-Young;Ha, Mi-Kyoung
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.27-36
    • /
    • 2009
  • Lately construction companies are differentiating the outdoor spaces of apartment complexes to satisfy the needs of residents by providing underground parking area and variety of outdoor community spaces. Building walking networks through residential unit area, the major passage area and the entrance area of the complexes is very important factor to increase the use of the outdoor environment in the complexes. The purpose of this study is to evaluate the characteristics and the elements for the planning of exterior pedestrian spaces carefully through the analysis of current large-scale apartment complexes. In this study, the utilization of space, the connectivity to other spaces and the application of Universal design were evaluated through site visits in 5 large-scale apartment complexes. As a result, the utilization of space is well applied in the most of complexes especially in residential unit area. The connectivity to other spaces has low application compared to the others. Universal design is also well applied except sub criteria for the blind in most of complexes. This study will be able to help in providing better exterior pedestrian environment for residents in apartment complexes.

A Survey of the Air Quality in Underground Environment (지하환경의 대기오염물질 규제에 관한 조사연구)

  • Lee M. H.;Han E. J.;Shin C. K.;Chung H. D.;Han J. K.
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.47-58
    • /
    • 1986
  • The underground living spaces have become one of the major environment of this decade in urban area. This study was carried out to examine contamination level for purpose of preservation of the pleasant underground environment. Three subway stations and three underground shopping centers in Seoul and two underground shopping centers in Busan were selected and surveyed by measuring gaseous pollutants $(SO_2,\; NO_2,\;CO,\;HC,\; HCHO,\;CO_2)$, dust, airborne microbes, and the other air condtions (temperature, humidity, air pressure, air flow, kata cooling power). These examined data were compared with four kinds of standard (building sanitation management, room air quality standards, occupational safety and health standards, ventilation equipment) as environmental hygiene.

  • PDF

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

A study on simulation modeling of the underground space environment-focused on storage space for radioactive wastes (지하공간 환경예측 시뮬레이션 개발 연구-핵 폐기물 저장공간 중심으로)

  • 이창우
    • Tunnel and Underground Space
    • /
    • v.9 no.4
    • /
    • pp.306-314
    • /
    • 1999
  • In underground spaces including nuclear waste repository, prediction of air quantity, temperature/humidity and pollutant concentration is utmost important for space construction and management during the normal state as well as for determining the measures in emergency cases such as underground fires. This study aims at developing a model for underground space environment which has capabilities to take into account the effects of autocompression for the natural ventilation head calculation, to find the optimal location and size of fans and regulators, to predict the temperature and humidity by calculating the convective heat transfer coefficient and the sensible and latent heat transfer rates, and to estimate the pollutant levels throughout the network. The temperature/humidity prediction model was applied to a military storage underground space and the relative differences of dry and wet temperatures were 1.5 ~ 2.9% and 0.6 ~ 6.1%, respectively. The convection-based pollutant transport model was applied to two different vehicle tunnels. Coefficients of turbulent diffusion due to the atmospheric turbulence were found to be 9.78 and 17.35$m^2$/s, but measurements of smoke and CO concentrations in a tunnel with high traffic density and under operation of ventilation equipment showed relative differences of 5.88 and 6.62% compared with estimates from the convection-based model. These findings indicate convection is the governing mechanism for pollutant diffusion in most of the tunnel-type spaces.

  • PDF

Study on Management System of Ground Sinking Based on Underground Cavity Grade (공동관리 등급에 따른 지반함몰 관리등급제에 대한 연구)

  • Lee, Kicheol;Kim, Dongwook;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.23-33
    • /
    • 2017
  • Due to the rapid development of cities, densities and heights of urban structures are increased, and much larger and more underground spaces are being developed accordingly. Increasing development of underground spaces has induced more ground sinks and underground cavities. Therefore, safety of people is threatened by potential ground collapses and possible accidents, which may result from underground cavity. To actively respond against potential danger of ground sink, evaluation of existing cavity grade and development of recovery procedure are important. There exists the ground sinking management grade system of expressway developed as local standards in Japan. Recently, ground sinking management grade system of Seoul was developed with consideration of road and asphalt conditions. In this study, 209 underground cavities of ${\bigcirc}{\bigcirc}$ area were explored and their cavity shapes and grades were evaluated based on both ground sinking management grade systems of Japan and Seoul. Comparison is made between cavity grades evaluated based on both grading systems from Japan and Seoul. As a result of comparative analysis, the conservatively-estimated cavity grades requiring emergency restoration based on the Japanese management grade system of expressway result from neglection of layer thickness of surface pavement, considering only width and cover depth of a cavity.

A Study of Connecting Space Designs in the Development of the Underground Space -focused on University and Subway Area- (지하공간개발에서의 연계공간 디자인연구 -대학가와 지하철역을 중심으로-)

  • 박전자
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.17-30
    • /
    • 1998
  • Through the rapid growth of Korea for the effectiveness and rationalization of the use of land the development of the underground land is mostly needed. Especially I think that in the limited country(like Korea) when we consider that the population of metropolitan area is almost a third if a total population of this country it is time that we should consider the method of transfer for using of under ground not of on the ground from the legal or systematic recognition of the land. In this respect it is necessary that the person involved in the urban development (the person for architect urban development landscape architect and adminstratives) should pay much attention to the using of the underground spaces.

  • PDF

Planning, design and construction of the cavern arena: Heating, Ventilation and Air Conditioning (GJOEVIK올림픽 경기장(난방 및 환기분야))

  • Mathisen, Hans-Martin;Lee, D.W.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.10b
    • /
    • pp.213-218
    • /
    • 1993
  • The paper deals with problems connected with heating and ventilation of underground premises for public use. Some properties of rock and special problems connected with designing ventilation systems for underground spaces are first briefly discussed. The rest of the paper deals with design of ventilation and heating systems. The conclusion is that there are no large problems with heating and ventiliation of underground premises, but there are still problems connected with for instance thermal properties of rock when water flows in the cracks. An optimum design demands better knowledge of these properties.

  • PDF

Radon in the Underground Workplaces; Assessment of the Annual Effective Dose due to Inhaled Radon for the Seoul Subway Station Staffs

  • Song, Myeong-Han;Chang, Byung-Uck;Kim, Yong-Jae;Lee, Hwa-Yong;Heo, Dong-Hey
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.163-166
    • /
    • 2010
  • The effective dose of the Seoul subway staffs due to inhaled radon ($^{222}Rn$) in their workplace was investigated depended on radon concentration exposed at each workplace, and working hours and working types of the staffs. Annual average radon concentrations ranged from 16.5 to 93.0 $Bq{\cdot}m^{-3}$. The staffs commonly spend 2,304 hours in the underground spaces a year. With the radon concentrations and the working hours of the staffs, estimated annual effective doses ranged from 0.23 to 0.73 $mSv{\cdot}y^{-1}$.

Analysis of Factors for Selecting Construction Methods for Underground Structures (지하구조물의 공법선정을 위한 요인분석)

  • Kang, Hyun-Jung;Rhim, Hong-Chul;Park, Sang-Hyun;Lee, Ghang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.37-40
    • /
    • 2007
  • As a demand for underground structure is increasing with more parking and retail spaces required. Various construction methods are reviewed and selected for each specific site for economical and fast construction. In this study, factors for selecting construction methods were categorized for substructure construction. Construction processes of substructure are consisted of methods for excavation, earth retaining systems, and placement of slabs. Factors for the selection of substructure construction method are the condition of surrounding, geotechnical, information and constraint by comfortness for others nearby. After survey for the construction data of 5 different sites, analysis about reliable substructure construction selection method was suggested.

  • PDF

Waterproofing and Root Barrier Construction Design for Artificial Green Roof System of Residential Apartment Underground Parking Lots (공동주택 지하주차장 상부 인공지반녹화층 방수 및 방근 설계 방안)

  • Lee, Jung-Hun;Kim, Bum-Soo;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.337-338
    • /
    • 2018
  • In recent years, residential apartment building parking lots are built in underground spaces, and with conjunction to improve the environment of the urban area, artificial greeen roof systems are installed on the upper slabs. However, early plant growth are resulting in root penetration into concrete cracks and in turn into the waterproofing membranes, leading to degradation and damaging of the waterproofing system and structural durability. This issue highlights a problem of conventional maintenance system of concrete structures, and proposals for amendments follow. In this study, a waterproofing and root barrier construction design for the upper slabs of residential building underground parking lots is proposed, and motioned to be added into future construction specifications.

  • PDF