• Title/Summary/Keyword: underground pollution points

Search Result 9, Processing Time 0.027 seconds

A Study on Environment Change According to Land Development Plan of Cheju Island Using GSIS Technique (GSIS를 이용한 제주도 국토개발에 따른 환경변화에 관한 연구)

  • 이병걸;강인준
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • The purpose of this paper is to present the environment change of Cheju Island as land development process using GSIS(Geo-Spatial Information System) technique. We implemented the process based on the maps of soil color, underground water pollution points, land use, land development planning and land sight seeing supported by Cheju Province Office. To use the maps for GSIS data, first we transformed the picture data of the office into raster structured picture data using scanner. Second, the coordinate system was added to raster data using 1/50000 geographic map. Third, we estimated land planning process using GSIS technique(overlay and reclass technique). The results showed that land development effected the natural environment(forest, green field, farm land). However, the chemical pollution and land sight seeing was not so much effected by the land development that was found.

  • PDF

Construction of Three Dimensional Soil Cadmium Pollution Map Using Geotechnical Information DB System (국토지반정보시스템을 이용한 3차원 토양오염지도 구축)

  • Hwang, Dae Young;Kang, In Joon;Jang, Yong Gu;Kim, Soo Kyum
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.13-19
    • /
    • 2016
  • This study presented the build-up of three-dimensional soil pollution map for precise analysis. To do this, survey on the existing pollutant region on Dongnae-gu, Busan that is the study subject, showed that it tended to produce 0.72 clusters. So, this study suggested to investigate center of $1km{\times}1km $ grid and, as the results of comparing the pollution map that input pollution figure values based on the actually investigation point showed precise results. And, it divided the standard of pollution into 5 levels in surface and underground space and the map was built up using IDW interpolation against the amount of polluted substance. The pollution of ground surface, flow of polluted substance, coefficient of permeability and ground water level that are 504 geotechnical informations were selected as the influential parameters in pollution analysis of underground space, and it calculated that to 0~20 points by dividing the characteristics. It enables the build-up of pollution map of ground surface-underground with depth that considers the characteristics of soil layers and it is considered that it is possible to analyze the general infiltration. And, it was considered that it enables more accurate forecast about influential analysis per depth and pollution of underground water.

A Study on the Pollution Sources of Simple water Supply Piped System using Statistical Analysis (통계적 분석을 이용한 간이급수시설의 오염원에 관한 연구)

  • 이홍근;김현용;백도현;김지영;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.56-67
    • /
    • 1999
  • This study was performed to suggest the basic data and plans for the establishment of safe water supply plans in simple water supply piped system in the rural areas. In 4 different places, 24 points of water sources 36 points of taps from water sources were sampled. Of the whole 60 points, 55 points were ground water and 5 points were surface water. 14 items were measured for the analysis of water quality on each samples. The measured items were analyzed again by statistical method ; cluster analysis and principle components analysis. The results of this study are as followed. 1) In water quality analysis on water sources, 4 items, bacteria, E.coli, NH3-N and Fe exceed the standard. Of 24 points, 20 points(83%) on bacteria, 1 point(4%) on NH3-N and Fe exceed the standard. 2) In water quality analysis on near and remote taps, 4 items, bacteria, E.coli, NH3-N and Fe , exceed the standard. Of 36 points, 20 points (81%) on bactria, 1 pint(3%) on NH3-N and Fe exceed the standard. 3)Cluster analysis on water quality shows the differences by the kinds of water sources, geographical characteristics and distance from water sources. 4) Principle components analysis on ground water shows that Factor 1 and Factor 3 are natural fluctuation by the content of soil. Also, Factor 2 and Factor 4 are penetration of pollutants to underground. Therefore, it is needed to take deeper ground water in order to prevent from pollution in the areas which have ground water as water source . 5) Principle components analysis on surface water shows that Factor 1 is penetration of vacteria from surface to water source when rainfalls. Also, Factor 2 is fluctuation of water quality by the geographical characteristics. Therefore, the counterplans against non-point pollution source must be taken. Filtration and disinfection facilities are needed in the areas which have surface water as water source.

  • PDF

Analysis of air pollution in subway area of Busan Metropolitan City (부산광역시 지하철역 지하공간의 대기오염 특성)

  • Lee, Hwa-Woon;Jang, Nan-Sim;Kwak, Jin;Lee, Hee-Ryung;Kim, Hee-Man
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

Development of Database Management System for Agriculture Facilities Using Geographic Information System (GIS를 이용한 농업시설물 데이터베이스관리시스템 개발)

  • An, Won-Tae;Choi, Seok-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.570-579
    • /
    • 2021
  • The environments in current farming and fishing communities have been exacerbated by the shortage of personnel caused by aging, the deficiency of equipment, and the decrease in produce prices. To help solve these issues, this study examined the history, such as inspections, failures, and repairs, by constructing a database for underground water wells, pumping stations, and irrigation, which are critical for management among agriculture production infrastructures. In particular, in the case of underground water wells, their optimal locations were determined using spatial information, such as a geological map of water resources, a water vein map, and underwater depth, because indiscreet installations and an absence of spatial information resulted in economic losses and environmental pollution. Therefore, this study could efficiently manage many facilities scattered in rural areas by developing a system. An analysis of the status of 14 underground water wells using spatial information showed that the location information at six points was specified incorrectly. On the other hand, a site investigation showed that the water vein map analysis at one point was inaccurate.

Application of 275kV XLPE Power Cables for Overseas Protect (275kV XLPE절연 전력케이블의 해외프로젝트 적용)

  • Kwon, B.I.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1736-1738
    • /
    • 2002
  • Oil-filled power cables and XLPE power cables have been globally applied for extra-high-voltage underground power transmission lines. The application of XLPE cables for the transmission lines have been largely increased at the domestic and overseas projects because of some issues. O.F cables have some week points, related with the issues of the environmental pollution and the needed maintenance work, even though they have been applied for several ten years and their reliability has been proven. Meanwhile, the demands on XLPE power cables increase as their manufacturing technologies have been improved and their simplicity of installations has been focused on. In Korea, for the first time, the 275kV XLPE cable is to be applied at an overseas power plant project. This paper introduces the project profile, the design of the XLPE cable and its accessories, the cable system design and the installation design.

  • PDF

Reduction Methods of Indoor hiy Quality on the Subway Station using by Ventilation (환기를 이용한 지하 역 실내 공기질 개선 방안)

  • 박덕신;정병철;조준호;정우성
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.139-146
    • /
    • 2001
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced radioactive decay of the element radium. And, radon is one of the major indoor air pollutants moves into the underground space through various routes and is considered to cause lung c hurting the lung tissues, In this study, we measured the subway radon level at 9 stations o According to test results, we can figure out the concentration of radon by lines, times, and m points. So, it was found that ventilation conditions are the most important factors in the su quality. Finally, we suggested effective and economic management methods of air pollution subway.

  • PDF

Influence of Ventilation on the Subway Radon Level (환기에 의한 지하 역의 라돈농도 변화)

  • 박덕신;정우성;정병철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.62-67
    • /
    • 2000
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced by the radioactive decay of the element radium. And, radon is one of the major indoor air pollutants. Radon moves into the underground space through various routes and is considered to cause lung cancer by hurting the lung tissues. In this study, we measured the subway radon level at 9 stations of 3 lines. According to test results, we can figure out the concentration of radon by lines, times, and measuring points. So, it was found that ventilation conditions are the most important factors in the subway air quality. Finally, we suggested effective and economic management methods of air pollution in the subway.

  • PDF

Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City (부산광역시 지하철 내의 대기오염도 분석)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • Journal of Environmental Science International
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.