• 제목/요약/키워드: underground oil storage cavern

검색결과 33건 처리시간 0.02초

과지압 암반 내 대규모 지하 유류비축기지 안정성 평가 및 Microseismic 계측 (Stability evaluation and microseismic monitoring around Large Underground Oil Storage Cavern in Over-stressed Rock Mass)

  • 이희석;이대혁;김호영;홍지수;최영태;김석진;박연준
    • 한국터널공학회:학술대회논문집
    • /
    • 한국터널공학회 2005년도 학술발표회 논문집
    • /
    • pp.189-201
    • /
    • 2005
  • Brittle failure has been detected in over-stressed rock mass during the construction of oil storage cavern. The main characteristics of stress induced brittle failure of the site are introduced. Various evaluation and measures are sought to stabilize the over-stressed rock mass. The major results from numerical analysis of the cavern are presented, and from current microseismic monitoring to detect hazard from brittle failure are presented.

  • PDF

원유 저장용 지하공동의 건설중 점토 그라우팅에 의한 지하수 제어 (Countrol of Groundwater by Clay Grouting in Undergroun Excavation of Oil Storage Caverns)

  • 김치환;박창우;이석천
    • 터널과지하공간
    • /
    • 제3권1호
    • /
    • pp.24-32
    • /
    • 1993
  • Groundwater movement is one of the most important elements in the construction and management of underground oil storage cavern. To control the groundwater flow, grouting is run in parallel with water curtains. But as traditional grouting is conducted within cavern before and after excavation, the effect of grouting is delayed and the injection sphere is limited in the rock mass. Therefore, it is desirable to introduce a more extensive and effective grouting. This article is to present the caly grouting, which was the first to be carried out in the construction of underground caverns for oil storage in Japan. After conducting the clay grouting, the effect was confirmed by ground water level and infiltration quantity to the caverns.

  • PDF

지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구 (A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern)

  • 정현영;송무영;이경주
    • 지질공학
    • /
    • 제11권1호
    • /
    • pp.37-50
    • /
    • 2001
  • 서울 근교의 화강편마암지역 지하 석유비축기지 주변 지하수계 모델링 연구를 통하여, 기지 인근에서 지하수를 개발할 때의 영향 및 지하수 개발의 악영향 저감을 위한 수벽공 설치의 효과 등을 파악하고, 실제 설치 후의 영향을 측정하여 모델링 결과와 비교 분석하므로서 기지의 관리 및 운영에 참고하고자 하였다. 심부 지하수를 개발한 경우의 기지 주변의 지하수 유동체계 분석, 그리고 이 개발 위치와 기지 사이에 수벽공을 설치했을 경우의 유동체계를 MODFLOW 수치해석방법으로 분석하였다. 기지 주변 관측공의 실제 지하수위는 EL.+30∼60m 범위에서 변동하며, 모델링 결과는 EL.+20∼50m 범위에서 변동하여 유사한 양상을 보이고 있다. 지하수 개발에 의해 기지 주변의 수위가 하강하였다가 수벽설치 후에 회복되었음을 수치해석을 통해 확인할 수 있었다. 지하지질구조 및 수리지질 요소를 적절히 입력하고 효과적인 모델링 연구를 수행하여 기지의 운영에 기여하였음을 확인하였다.

  • PDF

지하유류비축공동(地下油類備蓄空洞)의 수밀성(水密性)에 관한 연구(硏究) (Water Tightness around Under-ground Oil Storage Cavern)

  • 정형식;선용;김운영
    • 대한토목학회논문집
    • /
    • 제2권4호
    • /
    • pp.33-38
    • /
    • 1982
  • 지하류비축동굴의 성패는 지하수에 의하여 공동(空洞) 주위에 유지되는 수밀성(水密性)에 있다. 수밀성(水密性)이 보장되면 동굴에 저장된 유류의 gas가 유출되지 않으며 인접공동(空洞)이 비어 있을 시 이곳으로 이동하지 않는다. 본 연구에서는 전기상사모형실험(電氣相似模型實驗)을 통하여 동굴형태가 gas누출에 미치는 영향과 여러 가지 형태에서 유류이동을 방지하는 지하수위, 동굴내의 유류수준, 동굴간격 등이 검토되었다. 연구결과 동굴의 천정이 큰 곡율을 갖고 있으면 gas누출이 방지될 수 있음이 입증되었고 유류이동을 방지하는데 필요한 자연지하수위, 공동내의 유류수준 및 공동간격이 도표로 주어졌다.

  • PDF

지하유류비축공동(地下油類備蓄空洞)에서 Water Curtain의 효율성(効率性)에 관한 연구(硏究) (A Study on the Efficiency of Water Curtain around the Underground Oil Storage Cavern)

  • 정형식;이익효
    • 대한토목학회논문집
    • /
    • 제3권3호
    • /
    • pp.87-94
    • /
    • 1983
  • 지하유류비축공동(地下油類備蓄空洞)의 성패(成敗)는 공동상부(空洞上部)에 충분(充分)한 수두(水頭)를 유지(維持)하여 공동주위(空洞周圍)의 수밀성(水密性)을 보장(保障)하는 데 있다. 공동상부(空洞上部)에 충분(充分)한 수두(水頭)가 유지(維持)되면 저장(貯藏)된 유류(油類)의 Gas가 누출(漏出)되지 않으며, 인접공동(隣接空洞)이 비어있을 때에도 이곳으로 유류(油類)는 이동(移動)되지 않는다. 본(本) 연구(硏究)에서는 전기상사모형실험(電氣相似模型實驗)을 통(通)하여 수평(水平) 및 수직(垂直) Water Curtain을 설치(設置)하여 Gas 누출(漏出)과 유류이동(油類移動)을 방지(防止)하려 할 때 효과적(効果的)인 Water Curtain의 위치(位置), 인접공동간격(隣接空洞間隔) Water Curtain 수두(水頭), Bore-hole 간격 등이 검토(檢討)되었다. 연구결과(硏究結果) 공동(空洞)의 간격(間隔)이 좁으면 수직(垂直) Water Curtain은 꼭 설치(設置)되어야 하며, 공동간격(空洞間隔)이 공동(空洞) 높이의 2배 이상 커지면 수직(垂直) Water Curtain은 필요(必要)없다는 것이 입증(立證)되었고 유류이동(油類移動)을 방지(防止)하는데 필요(必要)한 수평(水平) 및 수직(垂直) Water Curtain의 위치(位置), Water Curtain 수두(水頭), Bore hole 간격 등이 도표(圖表)로 주어졌다.

  • PDF

국내 원유 비축 지하공동의 조사 및 설계 사례 (Investigation and Design of Underground Cavern for Oil Storage in Korea)

  • 김치환
    • 터널과지하공간
    • /
    • 제2권2호
    • /
    • pp.190-198
    • /
    • 1992
  • This study is to summarize the contents for the investigation and design of the construction for oil storage. Since underground caverns are large scale, in their construction one should consider the mechanical stability of caverns and the economic view of construction. On the basis of them, cavern's section and layout were determined and water curtains were designed to maintain hydraulic equilibrium so that gases were sealed tightly. Also the supporting criterial for rock bolt and stotcrete were determined by means of the classification of rock masses and the results of finite element method. The criteria of grouting reinforcement were presented according to the results of injection test in the pilot holes of working face.

  • PDF

발파진동에 대한 인접한 지상 저장탱크의 안정성 평가 (Stability Assessment of an Adjacent Ground Storage Tank by Blast-induced Vibration)

  • 정용훈;이정인;최용근
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.19-26
    • /
    • 2006
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern for the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle area of the underground storage cavern. Based on the blast-induced nitration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the adjacent ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

음향미소진동기반 모니터링 시스템을 이용한 지반구조물(유류 지하저장시설) 진단평가 가이드라인 (Guideline for the Diagnose of Geotechnical Structure (Underground Oil Storage Cavern) using a Microseismic Monitoring System)

  • 천대성;정용복
    • 터널과지하공간
    • /
    • 제28권4호
    • /
    • pp.293-303
    • /
    • 2018
  • 모니터링은 여러 방법과 장치를 이용하여 공학적 정보를 정확하게 수집하여 분석하는 행위를 말한다. 모니터링의 목적은 설계확인, 시공관리, 품질관리, 안전관리, 구조물 성능 확인 등이 있으며, 지반구조물진단평가는 구조물의 성능 확인에 해당하는 것으로 구조물이 사용 개시 후 환경 변화나 경년에 의해 누적된 피로 손상도를 고려하여 구조물의 건전도 판단을 목적으로 한다. 근래 국내에서 많이 알려진 음향미소진동은 구조물의 교란이 없는 상태에서 미세 수준의 손상을 감지하여 안전관리 및 구조물의 성능 확인에 활용될 수 있다. 본 보고는 음향미소진동 모니터링 기법을 이용하여 유류지하저장시설을 진단평가하는 절차에 대한 가이드라인을 소개한다. 가이드라인에는 모니터링 시스템 선정, 센서 배열과 설치 및 시스템 운영, 해석 등을 다루고 있다.

발파진동에 대한 구조물 안정성 평가 - 지하비축기지 건설 사례 (A Case Study on the Stability Assessment of Structures by Blast-induced Vibration)

  • 이정인;최용근;정용훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.479-484
    • /
    • 2005
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle part of the underground storage cavern. Based on the blast-induced vibration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the nearest ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

  • PDF

국내원유비축지하공동의 조사 및 설계 (Investigation and Design of Underground Cavern for Oil Storage in Korea)

  • 김치환;이석천
    • 화약ㆍ발파
    • /
    • 제12권1호
    • /
    • pp.32-38
    • /
    • 1994
  • This study Is to summarize the contents for the investigation and design of the construction for oil storage. Since underground caverns are large scale, in their construction one should consider the mechanical stability of cave·rns and the economic view of construction. On the basis of them, cavern's section and layout were determined and water curtains were designed to maintain hydraulic equilibrium so that gases were sealed tightly. Also the supporting criteria for rock bolt and stotcrete were determined by means of the classification of rock masses and the results of finite element method. The criteria of grouting reinforcement were presented according to the results of injection test in the pilot holes of working face.

  • PDF