• Title/Summary/Keyword: underground oil storage cavern

Search Result 33, Processing Time 0.021 seconds

Stability evaluation and microseismic monitoring around Large Underground Oil Storage Cavern in Over-stressed Rock Mass (과지압 암반 내 대규모 지하 유류비축기지 안정성 평가 및 Microseismic 계측)

  • Lee Hee-Suk;Lee Dae-Hyuck;Kim Ho-Yeong;Hong Jee-Soo;Choi Young-Tae;Kim Seok-Jin;Park Yeon-Jun
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.189-201
    • /
    • 2005
  • Brittle failure has been detected in over-stressed rock mass during the construction of oil storage cavern. The main characteristics of stress induced brittle failure of the site are introduced. Various evaluation and measures are sought to stabilize the over-stressed rock mass. The major results from numerical analysis of the cavern are presented, and from current microseismic monitoring to detect hazard from brittle failure are presented.

  • PDF

Countrol of Groundwater by Clay Grouting in Undergroun Excavation of Oil Storage Caverns (원유 저장용 지하공동의 건설중 점토 그라우팅에 의한 지하수 제어)

  • 김치환;박창우;이석천
    • Tunnel and Underground Space
    • /
    • v.3 no.1
    • /
    • pp.24-32
    • /
    • 1993
  • Groundwater movement is one of the most important elements in the construction and management of underground oil storage cavern. To control the groundwater flow, grouting is run in parallel with water curtains. But as traditional grouting is conducted within cavern before and after excavation, the effect of grouting is delayed and the injection sphere is limited in the rock mass. Therefore, it is desirable to introduce a more extensive and effective grouting. This article is to present the caly grouting, which was the first to be carried out in the construction of underground caverns for oil storage in Japan. After conducting the clay grouting, the effect was confirmed by ground water level and infiltration quantity to the caverns.

  • PDF

A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern (지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구)

  • 정현영;송무영;이경주
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Through the modeting study on the groundwater now system around the underground stockpile site of crude oil near Seoul, we carried out the research on the influence of the groundwater yield near the site, the effect of the water curtain construction in order to reduce the influence of water yield, and the realized case study by measuring the water level change after the construction of the water curtain. For the simu1ation of the water yield and the water curtain, the nwnerical analysis code, MODFLOW has been utilized. Groundwater levels of the observation wells which were established to observe the hydraulic head around underground oil storage cavern of the study area have been changed in the range of from EL.+30 to +60 meter, while the simulation study revealed that groundwater levels changed in the range of from EL.+20 to +5Om. The hydrogeological condition of the underground oil storage cavern becomes stable by injection water to maintain the groundwater level around the cavern. The result shows the proper input of the hydrogeological factors helps the management to be effective for the oil stockpile site.

  • PDF

Water Tightness around Under-ground Oil Storage Cavern (지하유류비축공동(地下油類備蓄空洞)의 수밀성(水密性)에 관한 연구(硏究))

  • Chung, Hyung Sik;Sun, Yong;Kim, Oon Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.33-38
    • /
    • 1982
  • A successful operation of underground oil storage cavern depends on water-tightness around cavern by groundwater. If water-tightness is not secured, gas bubbles would leak out and oil would migrate to an adjacent empty cavern. In this research an electrical analogy method was employed to study the influence of shape of cavern on gas leakage and the required natural groundwater level, relative oil level in two neighboring caverns and cavern spacing to prevent oil migration. The results show that gas leakage is prevented from a cavern with a ceiling of large curvature. The required values of factors to curtail the migration of oil are given on a graph.

  • PDF

A Study on the Efficiency of Water Curtain around the Underground Oil Storage Cavern (지하유류비축공동(地下油類備蓄空洞)에서 Water Curtain의 효율성(効率性)에 관한 연구(硏究))

  • Chung, Hyung Shik;Lee, Ik Hyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.87-94
    • /
    • 1983
  • The successful oil storage in the underground cavern is dependent on how to keep the water-tightness around the cavern by the groundwater. If the water-tightness is not secured, gas bubles will leak out and oil migrate to the adjacent empty cavern. An electrical analogy method was employed in studying the influences of the position of horizontal and vertical water curtains, the head of water curtain and the intervals of the cavern spacings and boreholes on the gas leakage and the oil migration into the adjacent empty cavern. The result shows that if the cavern spacing is narrow, the vertical water curtain should be established and if the cavern spacing is more than twice the cavern height, its establishment is not necessary. All the detailed factors required to prevent the oil migration are shown on graphs.

  • PDF

Investigation and Design of Underground Cavern for Oil Storage in Korea (국내 원유 비축 지하공동의 조사 및 설계 사례)

  • 김치환
    • Tunnel and Underground Space
    • /
    • v.2 no.2
    • /
    • pp.190-198
    • /
    • 1992
  • This study is to summarize the contents for the investigation and design of the construction for oil storage. Since underground caverns are large scale, in their construction one should consider the mechanical stability of caverns and the economic view of construction. On the basis of them, cavern's section and layout were determined and water curtains were designed to maintain hydraulic equilibrium so that gases were sealed tightly. Also the supporting criterial for rock bolt and stotcrete were determined by means of the classification of rock masses and the results of finite element method. The criteria of grouting reinforcement were presented according to the results of injection test in the pilot holes of working face.

  • PDF

Stability Assessment of an Adjacent Ground Storage Tank by Blast-induced Vibration (발파진동에 대한 인접한 지상 저장탱크의 안정성 평가)

  • Jong, Yong-Hun;Lee, Chung-In;Choi, Yong-Kun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.19-26
    • /
    • 2006
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern for the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle area of the underground storage cavern. Based on the blast-induced nitration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the adjacent ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

Guideline for the Diagnose of Geotechnical Structure (Underground Oil Storage Cavern) using a Microseismic Monitoring System (음향미소진동기반 모니터링 시스템을 이용한 지반구조물(유류 지하저장시설) 진단평가 가이드라인)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.293-303
    • /
    • 2018
  • Monitoring is the act of collecting and analyzing accurate engineering information using various methods and instruments. The purposes of the monitoring are design verification, construction management, quality control, safety management, and diagnose of structure etc.. The diagnose evaluation of the geotechnical structures corresponds to the confirmation of the structural performance. It is aimed to judge the soundness of geotechnical structures considering the degree of damage due to the environmental change and elapsed time. Recently, microseismicity, which is widely known in Korea, can be used for safety management and diagnoses of structure as it detects the micro-damage without disturbance of the structure. This report provides guideline on the procedure for assessing an underground oil storage cavern using microseismic monitoring techniques. Guidelines cover the selection of monitoring systems, sensor array, sensor installation and operation of systems, and interpretation.

A Case Study on the Stability Assessment of Structures by Blast-induced Vibration (발파진동에 대한 구조물 안정성 평가 - 지하비축기지 건설 사례)

  • Lee, Chung-In;Choi, Yong-Kun;Jong, Yong-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.479-484
    • /
    • 2005
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle part of the underground storage cavern. Based on the blast-induced vibration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the nearest ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

  • PDF

Investigation and Design of Underground Cavern for Oil Storage in Korea (국내원유비축지하공동의 조사 및 설계)

  • Kim Chee Whan;Lee Seok Chun
    • Explosives and Blasting
    • /
    • v.12 no.1
    • /
    • pp.32-38
    • /
    • 1994
  • This study Is to summarize the contents for the investigation and design of the construction for oil storage. Since underground caverns are large scale, in their construction one should consider the mechanical stability of cave·rns and the economic view of construction. On the basis of them, cavern's section and layout were determined and water curtains were designed to maintain hydraulic equilibrium so that gases were sealed tightly. Also the supporting criteria for rock bolt and stotcrete were determined by means of the classification of rock masses and the results of finite element method. The criteria of grouting reinforcement were presented according to the results of injection test in the pilot holes of working face.

  • PDF