• Title/Summary/Keyword: underground lots

Search Result 120, Processing Time 0.033 seconds

Application Method of Integrated Information System on waterproofing Quality for Improving Structure Durability (구조물 내구성 향상을 위한 방수품질 관련 통합정보시스템 활용방안에 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Byoung-il;Oh, Sang-keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.339-340
    • /
    • 2018
  • Contemporary concrete structures make use of underground spaces as parking lots and other comfort facilities for efficiency purposes. As underground environmental conditions are in constant exposure to degradation factors from the environment such as groundwater, hydraulic and soil pressure, structural movement and settlement, structural defects in the form of leakage occur. Current maintenance regulations and regimes are unable to respond to this field, as degradation mechanisms in underground environments are still unclear. In this regard, this study proposes the utilization of integrated information sharing system that can provide various technical information for construction designs to prevent leakages in underground concrete structures.

  • PDF

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Underground parking lot planning study for electric vehicle charging and parking (전기자동차 주차 및 충전을 위한 지하주차장 계획연구)

  • Chin, Kyung Il;Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.39-44
    • /
    • 2013
  • As the use of electric vehicles perspectively increases, infrastructures for charging car batteries need to be properly planned for satisfying new requirements. This study aimed at theoretically investigating the relative laws, size of existing parking lots, and diverse car sizes for suggesting parking places for electric vehicles. In addition, potential problems for changing existing parking lots to new parking lots for electric vehicles were thoroughly considered. Based on the problem recognition, the feasibility, in particular, of the change of existing parking place to new place equipped with electricity charging systems was investigated. The comprehensive reviews and surveys revealed that additional systems for charging electricity need to be developed to be suspended on the ceiling for existing parking lots in order to prevent changing current layout of the space. This system will alleviate the perspective problems when the charging systems are located on the floor such as contamination, electric shock, and damage by cars. Further study will be followed for testing performance of the suggested systems in the actual parking lots.

Underground Space Development and Strategy in Korea (국내 지하공간 개발 및 대책)

  • Shin, Hee-Soon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.327-336
    • /
    • 2013
  • Approximately 70% of the Korean peninsula is composed of mountains, around 99,274 $km^2$. Even worse, population rate of Korea is the No.3 in the world now. Accordingly, it is necessary to develop the potential underground space actively with the concept of another territory to be utilized. The development of underground space should be considered not a choice but an indispensable issue. Since 1970s, many large-scale underground structures have been constructed like as crude-oil storage bins, liquefied petroleum gas storage caverns, and underground pumped storage powerplants. Also, In urban area, the underground facilities such as subway networks, underground shopping mall, underground pedestrian network, electric power tunnels, and car parking lots have been used extensively. The scale of Yeosu oil and gas underground storage facility and Seoul subway systems are one of the massive scale in the world. Recently, the trend of the development of underground space becomes more diverse and larger scale. The current status of Korean underground space developments and strategy are described in this paper.

Deep-Learning-Based Water Shield Automation System by Predicting River Overflow and Vehicle Flooding Possibility (하천 범람 및 차량 침수 가능성 예측을 통한 딥러닝 기반 차수막 자동화 시스템)

  • Seung-Jae Ham;Min-Su Kang;Seong-Woo Jeong;Joonhyuk Yoo
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.3
    • /
    • pp.133-139
    • /
    • 2023
  • This paper proposes a two-stage Water Shield Automation System (WSAS) to predict the possibility of river overflow and vehicle flooding due to sudden rainfall. The WSAS uses a two-stage Deep Neural Network (DNN) model. First, a river overflow prediction module is designed with LSTM to decide whether the river is flooded by predicting the river's water level rise. Second, a vehicle flooding prediction module predicts flooding of underground parking lots by detecting flooded tires with YOLOv5 from CCTV images. Finally, the WSAS automatically installs the water barrier whenever the river overflow and vehicle flooding events happen in the underground parking lots. The only constraint to implementing is that collecting training data for flooded vehicle tires is challenging. This paper exploits the Image C&S data augmentation technique to synthesize flooded tire images. Experimental results validate the superiority of WSAS by showing that the river overflow prediction module can reduce RMSE by three times compared with the previous method, and the vehicle flooding detection module can increase mAP by 20% compared with the naive detection method, respectively.

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

Opened Slab Based on Top-Down Method (개방형 슬래브를 이용한 지하 역타공법)

  • Jeon, Keum-Seok;Goh, Soo-Jin;Yom, Kyong-Soo;Rhim, Hong-Chul;Choi, Lin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.9-12
    • /
    • 2006
  • In recent years, construction site has developed lots of new methods and materials for Time-Cost Trade-off and improving constructability. In the case of underground construction, especially, there are many restrictions and difficulties. Shortening of the construction time in construction of underground, we use top-down method in undergroud wall. A open slab has been designed for the purpose of overcoming a weak point of former top-down method. This study based on open slab on the under ground top-down method, to more improve constructability, to introduce the effect and the performance of top-down method.

  • PDF

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.