• Title/Summary/Keyword: underground lots

Search Result 121, Processing Time 0.028 seconds

A Study on the Adoption of optimum Construction Method to prevent Condensation on the wall of Underground Parking Lot in Apartment Project (공동주택 지하주차장의 벽체(壁體) 표면결로방지(表面結露防止)를 위한 적정 공법 선정에 관한 연구)

  • Oh, Kil-Hwan;Lee, Il-Jae;Kim, Sung-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.101-104
    • /
    • 2007
  • Currently most of underground structures in domestic apartment projects are being designed for parking lot and essential parking area is growing due to the increase in car-holding number per household. Moreover, most underground parking lots of today are combined with basement, therefore a pleasant environment in underground space is strongly needed for the dwellers' use. However, there always occur high percentage of humidity and surface condensation in underground parking lot because of the nature of underground structure and they are having a bad influence on the comfort and health of dwellers. Therfore, this study is planned to compare and examine the porformance and properties of currently used construction methods to prevent condensation and finally present the most suitable method.

  • PDF

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

Underground facilities Detecting Accuracy (지하매설물측량의 정확도)

  • Lee, Jae-Kee;Cho, Jae-Ho;Lee, Jae-Dong;Park, Kyung-Yeol
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.5 no.1 s.9
    • /
    • pp.139-145
    • /
    • 1997
  • Rapid development of city has made a lots of urban facilities buried under ground, therefore how to bury underground facilities and how to operate them becomes more and more important. However, due to shortage of composite operation data for burying the facilities under ground, a lots of individual and nation's properties have been destroted and even many people killed. under the circumstances, we need to detect the facilities in detail and in accuracy and we can surgest for underground facilities detecting accuracy as below.

  • PDF

Formaldehyde Concentration Characteristics according to Type of Books and Furniture Arrangement in Bookstores (대형 서점 내 서적 종류 및 가구배치에 따른 포름알데히드 발생 특성)

  • Kang, Donghee;Jung, Chan Gwon;Kim, Sughwan;Lee, Sang-Jin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.4
    • /
    • pp.381-387
    • /
    • 2012
  • Utilization of underground floor is becoming the main issue of our society to maximize and diversify the potential of recent urban space. It has brought about the changes of underground floor. Recently there are lots of huge bookstores in these underground floor. Bleach, adhesive and ink used for manufacturing books pollute indoor air in bookstore. Therefore, the purpose of this study is to analyze indoor air quality in these large bookstores. Concentrations of carbon dioxide and formaldehyde in three large bookstores in Seoul were measured by presence and type of books and distance of main entrance which is well-ventilated. According to the data, space that places lots of volumes measured higher concentration of formaldehyde than that of non-existence books. Children's book section was measured more concentration of formaldehyde than other book section. Closer main entrance near outside, lower concentration of formaldehyde was measured. Concentration of carbon dioxide was affected by the number of people in bookstore.

  • PDF

A Study on the Need for Improvement of Fire Resistance Design in Underground Parking Lot due to Electric Vehicle Fire (전기자동차 화재에 따른 지하주차장 내화설계 개선 필요성 검토)

  • Kim, Hae-na;Park, Jun-Seo;Shin, Joung-Hyeon;Hong, Sang-Hun;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.235-236
    • /
    • 2022
  • Electric vehicle fires in underground parking lots are very dangerous, but it is judged that the current related laws and regulations do not change, which will cause problems. As a result of the analysis for the purpose of providing an electric vehicle in an underground parking lot, fire-resistance coating is essential as it can cause an explosion in the building members made of high-strength concrete when an electric vehicle fire occurs in an underground parking lot. Since a fire occurs, it is necessary to prevent electric vehicles from parking adjacent to each other.

  • PDF

A Survey of Autogas Car Driver's Attitude on Safe Driving (LPG 자동차 안전운행을 위한 운전자 의식조사)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • In this study, we surveyed 544 drivers, who had taken the education course for autogas car drivers, to figure out their safety awareness status including the recognition of hazards of gas leaking from autogas cars and response attitude toward them. As a result of the survey, we found out that 63% of the responders recognized the hazards of gas leakage and 79% preferred parking in the aboveground areas. For the necessity of introducing restrictions on autogas cars parking in underground lots, 58% of all responders answered yes while 71% of the responders aged over fifties and 73% of them who responded to have known the hazards of parking in underground answered in the affirmative. Furthermore, we found out that responders who had recognized the hazards preferred aboveground parking areas, and the responders who had preferred the aboveground recognized the hazards of parking autogas cars underground and felt the necessity of restricting them from parking in underground relatively high. Through the analysis of these results, we can analyse that the drivers who are aware of the hazards of gas leakage have higher safety attitude for hazards than the other drivers who are not aware of them.

  • PDF

Non-Destructive Precise Electromagnetic Surveying for the Deep Underground Utilities (고심도 지중매설물의 지하측랑을 위한 비파괴 정밀 전자측량)

  • 손호웅;이강원;김형수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.2
    • /
    • pp.109-121
    • /
    • 2003
  • Lots of various utilities are buried under the surface. The effective management of underground utilities is becoming the very important subject for the harmonious administration of the city. Ground Penetrating Radar(GPR) survey including other various underground survey methods, is mainly used to detect the position and depth of buried underground utilities. However, GPR is not applicable, under the circumstances of shallow depth and places, where subsurface materials are inhomogeneous and are composed of clay, salt and gravels. The aim of this study is to overcome these limitations of GPR and other underground surveys. High-frequency electromagnetic (HFEM) method is developed for the non-destructive precise deep surveying of underground utilities. The method is applied in the site where current underground surveys are useless to detect the underground big pipes, because of poor geotechlical environment. As a result, HFEM survey was very successful in detecting the buried shallow and deep underground pipes and in obtaining the geotechnical information, although other underground surveys including GPR were not applicable. Therefore this method is a promising new technique in the lots of fields, such as underground surveying and archaeology.

The Economic Analysis of Underground Parking Lot Frames adopting 8-Bay Parking Modules (8-Bay 주차모듈을 적용한 아파트 지하주차장 구조의 경제성 분석)

  • Yu, Yongsin;Yoon, Bohyung;Kim, Minsu;Kim, Taewan;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.1
    • /
    • pp.52-61
    • /
    • 2019
  • On 30 June, 2017, the Ministry of Land, Infrastructure, and Transport announced the minimum size of parking section will be expanded in parking lots. The expansion of parking section could lead to increase in apartment prices because of increase in total area of the parking lots. It is necessary to adjust the column spacing and number in the parking lots and to apply the 8-Bay long-span parking module with good parking efficiency. According to the study, the construction cost of the 6-Bay module and 8-Bay module was almost the same. But The 8-Bay module was more economical than the 6-Bay module because of the reduction in total area of 8-Bay multi-moduel. The Result of construction cost of 8-Bay modules, Removal Deck-plate RC system was most economical. While the construction cost of PC system was higher due to increase in volume of the member, it would ensure sufficient economy by reducing the girder height to apply a pre-stress method. Also, the construction cost of hollow slab system was the highest. But it could be used as the underground parking lots for apartment, because it had the lowest cost per square meter. This Study has a academic significance by proving the applicability of the 8-Bay Module to underground parking lot of apartment. And it is expected that this study will be used as basic data to derive optimal construction method that applies 8-Bay Module.

Numerical Evaluation of CO Gas Distribution in Underground Parking Lot (지하주차장 내부 일산화탄소 가스 분포의 전산 해석적 평가)

  • Kim Jae Won;Ham Kyoung-A
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.33-42
    • /
    • 2002
  • Numerical estimation for concentration of mono-carbon oxygen (CO) gas inside an underground parking lot with auxiliary jet fans for enhancement of ventilation is carried out by using a commercial program. Main interest lies on the diagnosis of the present ventilation system including position and selection of auxiliarly fans in addition to main suppliers and exhausts. Details of both flows and concentration of CO gas that is most important component among car exhaust gases are illustrated in this investigation and those are presented for engineering construction of an underground parking pool. Prediction data of computational work is also validated by real measurements of concentration of CO gas.