• Title/Summary/Keyword: underground development

Search Result 1,084, Processing Time 0.028 seconds

Integrated Surface-Groundwater Hydrologic Analysis for Evaluating Effectiveness of Groundwater Dam in Ssangcheon Watershed (쌍천 지하댐의 효용성 평가를 위한 지표수-지하수 통합 수문해석)

  • Kim, Nam-Won;Na, Han-Na;Chung, Il-Moon
    • Economic and Environmental Geology
    • /
    • v.44 no.6
    • /
    • pp.525-532
    • /
    • 2011
  • In this study, the usefulness of underground dam as a means for the sustainable development of groundwater, and its performance in the management of groundwater resources were analyzed. The fully integrated SWAT-MODFLOW was applied to the Ssangcheon watershed in Korea to evaluate the effectiveness of groundwater dam construction. After construction, the groundwater level raised in the upstream area of groundwater dam while lowered in the downstream area. Also, it is shown that the exchange rate of river-aquifer interactions increased in the upper area of the dam. Since the storage capacity of the aquifer largely increased in the upper area of the dam, the exploitable groundwater could be greatly increased as much. This study demonstrated that a groundwater dam was a very useful measure to increase the available storativity of groundwater aquifers. It also represented that the combined analysis using SWAT-MODFLOW was helpful for the design and opeation of groundwater dam in the Ssangcheon watershed.

Multiple-Silo Performance Assessment Model for the Wolsong LILW Disposal Facility in Korea - PHASE I: Model Development (월성 중저준위 처분시설 다중사일로 안정성 평가 모델 - 1단계: 모델개발)

  • Lim, Doo-Hyun;Kim, Jee-Yeon;Park, Joo-Wan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • An integrated model for groundwater flow and radionuclide transport analyses is being developed incorporating six underground silos, an excavated damaged zone (EDZ), and fractured host rock. The model considers each silo as an engineered barrier system (EBS) consisting of a waste zone comprising waste packages and disposal container, a buffer zone, and a concrete lining zone. The EDZ is the disturbed zone adjacent to silos and construction & operation tunnels. The heterogeneity of the fractured rock is represented by a heterogeneous flow field, evaluated from discrete fractures in the fractured host rock. Radionuclide migration through the EBS in silos and the fractured host rock is simulated on the established heterogeneous flow field. The current model enables the optimization of silo design and the quantification of the safety margin in terms of radionuclide release.

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Analysis of Subsidence Mechanism and Development of Evaluation Program (지반침하 메커니즘 분석 및 평가 프로그램 개발)

  • Choi Sung O.;Jeon Yang-Soo;Park Eu-Sup;Jung Yong-Bok;Chun Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.15 no.3 s.56
    • /
    • pp.195-212
    • /
    • 2005
  • Surface subsidence which occurs with several reasons, such as collapse of gangway, discharge of groundwater, compaction of weak rock mass, and tunnel excavation in shallow depth, gives rise to a serious problem in national infra-structures. In this study, therefore, the mechanism of subsidence has been examined numerically to overcome the passive approach on subsidence occurrence area. With many kinds of numerical studies, the major geotechnical parameters have been selected and the weighted values have been defined for each parameters. Also the authors developed the numerical program which can estimate the possibility of subsidence occurrence, and proposed the decision method for objective and quantitative guideline. It is anticipated that this research will be helpful to establish the hazard map on subsidence region.

A study on the capability of edge shape milling tool with the operatio parameters of equipment (장비운영요소변화에 따른 석재측면 성형공구의 성능시험 연구)

  • 선우춘
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.332-341
    • /
    • 1998
  • Conventional polishing of stone panel edges has been done by hand. While this has changed somewhat with the advent of automatic machines, it is still very much a hand finishing technology. For the development of edge shape milling tool, the primary test on characteristics of edge shape milling tool was carried out. This paper presents the results of tests focused upon the milling capability that was varied by the variables of operation parameters. Author tried to confirm the effect of six operation parameters of equipment such as rotation speed, advance speed, applied load, water flow rate and rotational direction. The result from test was described in term of shape milling capability that was defined as cutting volume of rock by unit weight of tool wear. The variance of the results could indicate the optimum level of each operating parameters. The test was also carried out to determine the abrasion resistance varied according to the abrasive flow rate. The abrasion resistance was increased with the abrasive flow rate, but over some rate it was not changed.

  • PDF

Effective Use of Water Resources Through Conjunctive Use - (II) Application (지표수-지하수를 연계한 수자원의 효율적 이용 - (II) 적용)

  • Kim, Su-Min;Lee, Sang-Il;Kim, Byeong-Chan
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.10
    • /
    • pp.799-812
    • /
    • 2004
  • Conjunctive use of surface and ground water has drawn much attention as a promising means to solve water shortage problems. Characterized by its maximum utilization of regional resources and environmental friendliness, conjunctive use is expected to contribute to the integrated water resources management in the coming era. This paper examines the applicability of the methodology for conjunctive use developed in the companion paper (this issue). The method consists of the entire process of conjunctive use, including site assessment using analytic hierarchy process, management scenario development based on drought analysis, and evaluation of benefits obtained. Sokcho City was chosen as the study area, and the application of derived operation scenarios for surface and subsurface reservoirs revealed that water of 4.9∼7.4 million cubic meters a year can be attainable additionally. The developed methodology enables one to devise management schemes and to quantify their effectiveness, which makes the method useful for water resources planners as well as practitioners.

Evaluation of Groundwater Flow through Rock Mass around Development Openings of Mine (광산 갱도 주변 암반에서의 지하수 유동 평가)

  • Yoon, Yong-Kyun
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.370-376
    • /
    • 2011
  • To design the drainage system of a mine, it is very important to evaluate the groundwater inflow to the mine workings. In this study, continuous steady state flow through rock mass around mine openings developed in Sungok area of Gagok Mine was analyzed. Saturated only model and Saturated/unsaturated model were used as material models of rock mass. Groundwater quantities flowing into Sungok 160 level which is 1216 m long are computed as 1450 $m^3$/day in case of a saturated model and as 1071 $m^3$/day in case of a saturated/unsaturated model. An effect that hydraulic conductivity has on inflow turned out be greater than precipitation and inflow increased linearly with increase of hydraulic conductivity. It was found that change of hydraulic conductivity ratio and orientation have an impact on the variation of inflow and water table.

Fire research in Sweden for 1997-99

  • Arvidsson, Tommy
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.44-48
    • /
    • 1997
  • The Swedish Fire Research Board was established in 1979 to initiate and fund relevant fire research efforts. The Board is responsible for a long term research programme revised every third year, and the Board is one of two major Swedish sponsors of all fire research. Beside the Board we also have the Swedish National Rescue Services, funded by the government. BRANDFORSK gives very high priority for the industry and the insurance company and the need they express for fire research. Research that the Rescue Services Board are funding is mainly focusing the need for the fire department. The Swedish Fire Research Board, BRANDFORSK, is the joint agency of the Swedish government, the insurance industry and the business sector, for the initiation, funding and supervision of different kinds of fire research. Work is directed by a Programme Board and is performed in the form of projects at universities, research institutes, state authorities and private firms. The Secretariat of BRANDFORSK shares the premises of the Swedish Fire Protection Association, SFPA, and the SFPA is the principal and the party which enters into agreement with the State. The programme for the period 1997-1999 has been drawn up on the basis of both damage development and the trends in society which can be noted, and the evident fire problems of the interested parties and their need for fire research. The inputs in the programme have been broken down seven problem areas. In every problem area different project areas are set out, and these primarily specify the aim of the work. Our seven problem-areas are; Costs and benefits of fire protection measure. The role and behaviour of people and organizations Fire In buildings Fire in underground facilities Rescue operations fire in industries Fire and the environment. In comparison with previous fire research programmes, cost/benefit studies have been accorded higher priority, and this is also reflected in other problem areas. Grater Emphasis

  • PDF

Analysis of the Influence of the Design Factors and Modeling for the 8inch Class Down-the-Hole Hammer (8인치급 다운더홀(DTH) 해머의 모델링 및 설계 인자에 따른 영향도 분석)

  • Lee, Chung No;Hong, Ki Chang;Jeong, Heon Sul
    • Journal of Drive and Control
    • /
    • v.14 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • The Down-the-Hole hammer is one of the pneumatic drill equipment used for grinding, drilling, and mining. One the advantages of which is that a reduction work efficiency at deep site are relatively small compared to other drilling methods. Due to the large vibration in the underground area, it is difficult to measure the performance of the hammer, and hammer testing requires substantial production cost and operating expenses so research on the development of the hammer is insufficient. Therefore, this study has developed a dynamic simulation model that apprehends the operating principles of an 8-inch DTH hammer and calculates performance data such as performance impact force, piston speed, and BPM. By using the simulation model, design factors related to strike force and BPM were selected, and the influence of each design factors on performance was analyzed through ANOVA analysis. As a result, be the most important for BPM and the strike force are position of upper port that push the piston in the direction of the bit and in BPM, the size of the empty space between the bits and the piston is the second most important design factor.

Vulnerability Evaluation of Groundwater Well Efficiency and Capacity in Drought Vulnerable Areas (가뭄 취약지역의 관정 효율 및 능력에 대한 취약성평가)

  • Shin, Hyung-jin;Lee, Jae-young;Jo, Sung-mun;Jeon, Sang-min;Kim, Mi-sol;Cha, Sang-sun;Park, Chan-gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.41-53
    • /
    • 2019
  • Recently, the damage caused by climate change has been distinguished in the world. The Korean Peninsula is also suffering from drought, so it is necessary to study the vulnerability assessment to identify and predict the state of the irrigation facility, which is a irrigation facility. As the damage caused by drought is occurring in the Korean peninsula, it is necessary to study the vulnerability assessment to know the condition of the irrigation facility, and to predict it. The target areas were Yeongdong-gun, Cheonan-si, Mungyeong-si, Geochang-gun, Muju-gun, and Yeonggwang-gun. The survey items were selected as positive impacts survey items, including precipitation, groundwater level, and pumping capacity per groundwater well. The negative impacts were selected as the cultivation acreage, Number of days without rain, and the ratio of private underground wells. The survey method was investigated by various methods such as "weather data portal", "groundwater level status information", "agricultural drought management system", "groundwater survey yearbook". The results of vulnerability assessment were expressed by the score by conducting survey and standardization. As a result, Yeonggwang-gun showed normal vulnerability, and other areas showed "vulnerable" or "very vulnerable".