• Title/Summary/Keyword: underground development

Search Result 1,084, Processing Time 0.027 seconds

Development of a Life Prediction Technology for Underground Metallic Structures Applied Cathodic Protection System (전기방식설비가 적용된 지하금속매설물의 수명예측기법 개발)

  • Ha, Tae-Hyun;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3172-3174
    • /
    • 2000
  • It is necessary to collect and analyze the corrosion date to control the underground metallic structures systematically. It can be possible to predict the remaining life of underground metallic structures. In this paper we describe the life prediction technology of cathodic protection systems and underground metallic structures without a cathodic protection system.

  • PDF

Inversion of Electrical Prospecting Data for Underground Tunnel Detection (전기탐사의 지하터널 조사를 위한 역산에 관한 연구)

  • Suh, Baek-Soo;Ko, Kwang-Beom
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.125-130
    • /
    • 1998
  • The undergound space is widely developed because of dometic industry and protection of enviornment. The existence and exact location of tunnel is very important for stability of the enormous underground storage house or building. Various types of prospecting methods have been applied to detection of underground tunnel. In this study, electrical prospecting method is applied to detect tunnel because the development of underground space is very connected with groundwater. Sensitivity analysis is introduced for the calculation of elctrical inversion data. The governing equation is Fourier transformed into the 2-dimensional wave number space and solved by using the finite element method.

  • PDF

Study on Development of Light Duct System for Perimeter Occupied Zone on Underground Space (지하대공간에 있어 Perimeter Occupied Zone에 대한 채광덕트 시스템 개발에 관한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.21-26
    • /
    • 1999
  • Using daylight in underground spoce may significantly reduce electric lighting load and give a visually comfortable environment. This reper describes a fundaIrentaI study on light duct system to predict inter illuminance ratio on underground periIreter occupied zone level. As a result, integral equation for inter-reflection program are developed and by using optimize light duct system can gives daylight on deep underground space. space.

  • PDF

A Study on the Activation Strategy of Underground Shopping Malls: Focusing on Public Underground Shopping Malls in Six Major Cities

  • KIM, Gi Pyoung;LEE, Yong Kyu;LEE, Guen Woo;YOU, Chang Kwon
    • The Journal of Industrial Distribution & Business
    • /
    • v.13 no.6
    • /
    • pp.39-49
    • /
    • 2022
  • Purpose: As part of these efforts, in-depth research is needed on efficient and practical utilization of underground spaces and underground shopping malls. In addition, efforts are being made to find effective alternatives to various problems currently occurring in underground shopping malls, but it is not easy. In addition, the development entity and the maintenance entity are different from each other, and the management is not unified, making it difficult to maintain underground shopping malls. From this point of view, it can be said that it is time to actively and specifically discuss ways to revitalize underground shopping malls. Data and methodology: In the domestic distribution environment, traditional markets and shops are stagnating due to rapid changes in consumption patterns, such as the spread of large companies with advanced distribution techniques such as hypermarkets, shopping malls, and SCM, the rapid increase in Internet and home shopping, and the importance of convenience for young consumers. In order to revitalize underground shopping malls, it is necessary to strengthen the organization and self-rescue efforts of merchants' associations, change consciousness through merchant education, change to specialized markets, find nuclear stores and representative restaurants, and support the hardware sector. Results: The connection of underground shopping malls in each region of the country, where commercial districts are separated from each other, will also play an important role in reviving the function of the city in the future. To do this, it is first necessary to connect underground shopping malls that have been cut off. In other words, connection between connectable underground shopping malls should be promoted. Of course, long-term projects should be promoted step by step, and many consultations should be made on how to connect with the ground for each local government. Conclusion: This is because in the future, the underground space cannot just be a walking place, but another space of the Korean Wave where you can experience satisfying the five senses. K-shopping Hallyu content can be created by creating a characteristic story for each underground shopping mall in the city, permanently this story-oriented event, and creating a safe and elegant environment. If there is a story, so-called "Senomi Shopping" will be possible. A new Korean Wave will be created that can satisfy "the fun of writing, the fun of seeing, and the fun of feeling" at the same time.

Development of Drawing Processing Tool Program and Establishment Strategy of 3D Underground Structures based on Standardized Drawings (표준도 기반의 3차원 지하구조물 구축 방안 및 도면가공 툴 프로그램 개발)

  • LEE, Min-Kyu;HAN, Sang-Hoon;KIM, Sung-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.1-25
    • /
    • 2021
  • In order to respond and prevent underground safety accidents, the Korean government has been preparing a submitting completion drawing web system project for converting the current manual-based 3D Underground Geospatial Map construction and its update system to an automation-based 3D underground information construction. However, research on standard drawings required for the automatic update of 3D underground structures is insufficient, so detailed research is needed. In this research paper, a standard map-based 3D underground structure construction plan was presented for the six types of underground structures constituting the 3D Underground Geospatial Map, enabling rapid and accurate drawing data creation and systematically 3D underground structure drawing data could be managed. In addition, we developed a 3D construction drawing tool that can be used in underground information practice so that ordinary CAD program users can easily produce processing drawings. The results derived from this paper are expected to be major reference materials for the establishment of standard frameworks and practical application guidelines for the construction of 3D underground structures in the future.

Development of Underground Facilities Management System on Subway Construction (지하철공사를 위한 지하매설물관리시스템 개발)

  • 강인준;장용구;정영미
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 1997
  • In other to construct a subway, we have to consider the position of the subway and acquisition of a topography, profile-map, cross-map, underground facilities map. All information of underground is demanded accurate location in other to prevent of accident of underground in subway construction. We must think about water lines, sewer lines, electronic lines, telephone lines, all urban gas-line because these are needed construction the subway. And attributes of underground facilities recorded on topography are characteristics. length, width. number, position, and depth of the lines. We have to record these attributes because these are very important to design map on subway construction. If we develop GIS (Geographic Information System) to use the exact in-formation of the underground facilities, we can be management safely and prevent very dangerous accident as fast as possible. In this study, attribute informations are linked geographic informations about underground facilities and we can develop Underground Facilities Management System(UFMS) to analysis dangerous region through dangerous degreed and predict accident range with these informations.

  • PDF

A Method to Protect Mine Workers in Hot and Humid Environments

  • Sunkpal, Maurice;Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.149-158
    • /
    • 2018
  • Background: Work comfort studies have been extensively conducted, especially in the underground and meteorological fields resulting in an avalanche of recommendations for their evaluation. Nevertheless, no known or universally accepted model for comprehensively assessing the thermal work condition of the underground mine environment is currently available. Current literature presents several methods and techniques, but none of these can expansively assess the underground mine environment since most methods consider only one or a few defined factors and neglect others. Some are specifically formulated for the built and meteorological climates, thus making them unsuitable to accurately assess the climatic conditions in underground development and production workings. Methods: This paper presents a series of sensitivity analyses to assess the impact of environmental parameters and metabolic rate on the thermal comfort for underground mining applications. An approach was developed in the form of a "comfort model" which applied comfort parameters to extensively assess the climatic conditions in the deep, hot, and humid underground mines. Results: Simulation analysis predicted comfort limits in the form of required sweat rate and maximum skin wettedness. Tolerable worker exposure times to minimize thermal strain due to dehydration are predicted. Conclusion: The analysis determined the optimal air velocity for thermal comfort to be 1.5 m/s. The results also identified humidity to contribute more to deviations from thermal comfort than other comfort parameters. It is expected that this new approach will significantly help in managing heat stress issues in underground mines and thus improve productivity, safety, and health.

Development of construction method for underground buildings with MSRC diaphram wall and study on flexural performance of MSRC diaphram wall (강재주열벽을 적용한 지하건축물 가설공법의 개발 및 강재주열벽의 휨성능 연구)

  • Chung, Jee-Seung;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.937-957
    • /
    • 2017
  • Urban roads are not only congested with vehicles and pedestrians, but also have many pipelines buried to provide convenience for inhabitants. In addition, urban inhabitants live comfortably in buildings adjacent to the road for residence, business, commerce, rest and so on. Therefore, despite the high cost of land, urban underground buildings with high land use efficiency are constantly being built. Recently, the construction of underground buildings has caused social problems such as the collapse of surrounding roads and adjacent buildings. Institutional improvement is being actively carried out to improve this. In this study, a new type of MSRC diaphragm wall was developed and a study on the construction method of underground building was carried out. It is intended to secure the underground excavation safety of underground buildings in urban areas and effectively prevent land subsidence complaints. Also, a reasonable design method of MSRC diaphragm walls using the ultimate strength design method is presented through the flexural performance Experiment.

The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point (지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정)

  • Kim, Jae-Hyun;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5123-5127
    • /
    • 2011
  • Research and development for the technology, that is about maintenance and accidents prevention of underground power distribution line, are demanding. The precise detection of leakage point of underground power line is very important, because it is difficult to detect the exact location of a fault in underground power line and to repair faults. When earth electric potential is measured to detect underground electric leakage point after transmitting AC electric pulse wave to underground power line, it must be measured in a specific half period of AC pulse wave because the distribution of the electric earth potential varies with the polarity of the transmitted wave. In this paper we proposed the measurement of half period modulated earth potential as a method to detect a underground leakage point. And We compared the proposed method with other methods. Through experiments we verified that the proposed method can be implemented and operated properly.

Correlation Analysis of the Occurrence of Ground Subsidence According to the Density of Underground Pipelines (지중관로 매설 밀집도에 따른 지반함몰 발생 상관 분석)

  • Kim, Jinyoung;Kang, Jaemo;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.23-29
    • /
    • 2021
  • Recently, ground subsidence has been steadily occurring mainly in downtown areas, threatening the safety of citizens. Under the road, various underground facilities such as water supply pipe, sewage pipe, and communication pipe are buried. Due to the aging of these underground facilities and the reckless development of the underground, it is acting as a cause of ground subsidence. Although there is a result of analyzing the risk of ground subsidence according to the deterioration of the existing pipeline, there is no result of analyzing the risk of ground subsidence using the density of pipelines indicating ground disturbance. Therefore, in this study, the density of the underground space was analyzed using the data of six types of representative underground pipelines in Seoul, and a study was conducted on whether there is a correlation with the ground subsidence. As a result, it was found that the density of underground facilities is high in the area where the ground subsidence occurred, indicating that the density of pipelines have an effect on the ground subsidence.