• Title/Summary/Keyword: underground air

Search Result 551, Processing Time 0.025 seconds

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City (부산광역시 지하철 내의 대기오염도 분석)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • Journal of Environmental Science International
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.

Measurement of Air Tightness of Concrete Block and its Construction Joint from a Model Experiment (모형실험을 통한 콘크리트 블록 및 시공이음부의 기밀성 측정)

  • Kim, Hyung-Mok;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.434-445
    • /
    • 2010
  • Underground compressed air energy storage (CAES) system in a lined rock cavern is considered one of the promising large-scale energy storage technologies. In this study, permeabilities of concrete lining block and its construction joint, which are the major components of an air tightness system of the undeground CAES, were measured from a model experiment. From the experiment, it was found that intrinsic permeability of construction joint was larger than that of concrete block by the order scale of $10^1{\sim}10^4$, so that it would be very important to control the quality of construction joints in-situ in order to secure air tightness of storage system. And the permeability of construction joint could be decreased as low as that of the concrete block by pasting an acryl-type adhesive on bonding surfaces. Higher degrees of water saturation of the concrete block resulted in the lower permeability, which is more preferable in the viewpoint of air tightness of storage cavern.

Particle Collection Efficiency of Axial- flow Cyclone with Outlet Shape (출구형상에 따른 축상유입식 싸이클론의 입자제거효율)

  • Kwon, Soon-Bark;Kim, Se-Young;Kim, Myung-Joon;Park, Duck-Shin;Jeong, Woo-Tae;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.128-131
    • /
    • 2011
  • Management of indoor air quality of underground subway station is an important issue. The air handling unit (AHU) installed in the underground subway station is the main facility determining the air quality of station. Especially for removing particulate matters, it is important to operate the appropriate air filter. In this study, we studied particle collection efficiency of axail-flow cyclone for subway AHU. The particle collection efficiencies of axial-flow cyclones with three different outlet shape have been evaluated.

  • PDF

Survey on Air Pollution in Underground Commercial Floor of Pusan Areas (부산지역 지하상가의 대기오염도에 관한 조사 연구)

  • 이채언;문덕환;조병만;김준연;배기철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.22-32
    • /
    • 1989
  • In order to assess the level of atmospheric pollution and to contribute the health improve ment of residents in Pusan, the authors measured the $CO, SO_2, NO_2, TSP, Noise, Pb, Cd, Cr and V$ level at 3 place by time from Jan. 1988 to Feb. 1988. THe places were Kukje, Daehyeon, Pujeon underground commercial floor. The results were as follows; 1. The range of concentration of air pollutants (1) CO : 0.5 - 3.0 ppm (2) $SO_2$ : 0.012 - 0.360 ppm (3) $NO_2$ : 0.018 - 0.089 ppm (4) TSP : 30 - 330 $\mug/m^3$ (5) Pb : 0.219 - 3.116 $\mug/m^3$ (6) Cd : 0.000 - 0.070 $\mug/m^3$ (7) Cr : 0.378 - 4.098 $\mug/m^3$ (8) V : 0.000 - 1.010 $\mug/m^3$ (9) Noise : 47 - 77 dB(A) 2. The level of all air pollutants were higher in the afternoon or night than in the morning. 3. The mean concentration of $SO_2$ in all places exceede the ambient air quality standard of $SO_2$,.

  • PDF

Stability Analysis of Compressed Air Storage Caverns in Rockmass (전력생산을 위한 암반내 압축공기저장공동의 안정성분석)

  • 신희순;신중호;최성웅;한일영;김정엽
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.287-294
    • /
    • 2002
  • CAES which is called as a compressed air energy storage was firstly developed at Huntorf, German in 1978. The capacity of that system was 290MW, and it can be treated as a first commercial power plant. CAES has a lot of merits, such as saving the unit price of power generation, averaging the peak demand, improvement of maintenance, enlarging the benefit of dynamic use. According to the literature survey, the unlined rock cavern should be proposed to be a reasonable storing style as a method of compressed air storage in Korea. We decided the hill of the Korea Institute of Geoscience and Mineral Resources as CAES site. If we construct the underground spaces in this site, the demand for electricity nearby Taejon should be considered. So we could determine the capacity of the power plant as a 350MW, This capacity needs a underground space of 200,000㎥, and we can conclude 4 parallel tunnels 550m deep from the surface through the numerical studies, Design parameters were achieved from 300m depth boring job and image processing job.

  • PDF

A Study on the Ventilation Schemes for Gas Leakage and Dispersion Controlling at the Backfilled Working Face in Large-Opening Underground Mine (대단면 지하광산 갱도내 뒷채움 작업장 가스유출 및 확산제어 통기방안 연구)

  • Nguyen, Vanduc;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.372-386
    • /
    • 2018
  • The air quality near the backfilled site area is significantly deteriorated during and even after the curing period of the backfill materials. Hazardous gases such as NH3 and CO2 may leak out prolongedly from the mined-out sites backfilled with the composite carbonate-based material; leakage can be observed at the underground working sites as well as on the surface. At operating mines, underground gas leakage will severely aggravate the workplace environment. The ventilation schemes should supply sufficient air to dilute the contaminated air, and control the toxic gas leakage and dispersion. This study shows the applicability of pressurization ventilation system to control gas leakage and dispersion at the backfilled underground mine site.

A Study on Heat Transfer of an Underground Power Transmission Cable-Joint (지중송전케이블 접속부에서의 열전달에 관한 연구)

  • Park, M.H.;Kim, J.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구)

  • 김윤신;이은규;엽무종;김기영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.3-5
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991-February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001-June 2001 in Seoul. The results were as follows : 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. 2. The average of staphylcocci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were Underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites

  • PDF

An Experimental Study of Flow Behaviour in Underground Stairway Fire (지하계단 화재에서 유동에 대한 실험연구)

  • 정진용;홍기배;이재하;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.821-827
    • /
    • 2003
  • Reduced-scale experimental study was carried out on the heat flow behavior which flows under the sloped ceiling in underground fire. Temperature and flow velocity were measured to characterize the ceiling jet along the sloped stairway ceiling. The methanol fuel was used as a model fire source giving 2.2 and 3.4 kW, with changing the slope angle of stairway adopting of 15, 25, 35, and 45 deg. Based on the experimental data, excess temperature and velocity along the sloped stairway ceiling were examined which are usefully applicable to estimate the activating conditions of heat detector and sprinkler head mounted on the sloped ceiling. Excess temperature in upper exit of the sloped stairway was also examined to analyze the soffit which delays the smoke diffusion. The result shows that the activating conditions of heat detector and sprinkler in the sloped stairway ceiling have to be considered differently in a point of about 30 deg.