Experimental and numerical investigation of RC sandwich panels with helical springs under free air blast loads

  • Rashad, Mohamed;Wahab, Mostafa M.A.;Yang, T.Y.
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.217-230
    • /
    • 2019
  • One of the most important design criteria in underground structure is to design lightweight protective layers to resist significant blast loads. Sandwich blast resistant panels are commonly used to protect underground structures. The front face of the sandwich panel is designed to resist the blast load and the core is designed to mitigate the blast energy from reaching the back panel. The design is to allow the sandwich panel to be repaired efficiently. Hence, the underground structure can be used under repeated blast loads. In this study, a novel sandwich panel, named RC panel - Helical springs- RC panel (RHR) sandwich panel, which consists of normal strength reinforced concrete (RC) panels at the front and the back and steel compression helical springs in the middle, is proposed. In this study, a detailed 3D nonlinear numerical analysis is proposed using the nonlinear finite element software, AUTODYN. The accuracy of the blast load and RHR Sandwich panel modelling are validated using available experimental results. The results show that the proposed finite element model can be used efficiently and effectively to simulate the nonlinear dynamic behaviour of the newly proposed RHR sandwich panels under different ranges of free air blast loads. Detailed parameter study is then conducted using the validated finite element model. The results show that the newly proposed RHR sandwich panel can be used as a reliable and effective lightweight protective layer for underground structures.

지열 이용 외기부하 저감시스템의 냉각 및 가열효과 예측 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제13권3호
    • /
    • pp.169-181
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

  • PDF

지상과 지하역사의 실내공기질 특성과 외기영향 평가 (Characteristics of indoor air quality in the overground and underground railway stations)

  • 남궁형규;송지한;김수연;김희만;권순박
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.17-25
    • /
    • 2016
  • 본 연구에서는 지하역사와 지상역사에서의 실내공기질을 측정하고, 외부 공기에 의한 영향 정도를 확인하고자 하였다. 측정된 물질은 '실내공기질 관리법'상에서 유지기준과 권고기준으로 지정된 항목 중, 농도가 검출되지 않은 석면을 제외한 미세먼지($PM_{10}$), 이산화탄소($CO_2$), 일산화탄소(CO), 이산화질소($NO_2$), 폼알데하이드(HCHO), 오존($O_3$), 총부유세균(TAB), 총휘발성유기화합물(TVOC), 라돈 등 9종이다. 또한 미세먼지, 이산화질소, 오존 등 세 가지 물질은 I/O ratio를 통해 외기에의한 영향을 확인하였다. 공기질 측정결과 지상역사에 비해 지하역사에서 미세먼지, 폼알데하이드, 총휘발성유기화합물, 이산화질소, 라돈 등이 높은 농도로 검출되었으며, 이는 지하역사 내부에 그 오염물질의 발생요소가 존재하기 때문으로 판단된다. 오존 농도는 지상역사에서 지하역사보다 높은 농도로 검출되었으며, 특히 외부로 노출되어있는 지상역사 승강장에서 높은 농도를 보임으로써 외기 유입에 의한 영향이 있는 것으로 확인되었다. 따라서, 외기에 의한 영향을 받는 오염물질은 역사의 기계환기시 제거 과정을 거쳐 오염물질의 실내유입을 차단하고, 지하역사에서 기인한 미세먼지 등의 물질들은 실내에서 그 발생원에 따른 별도의 처리가 필요할 것으로 판단된다.

실내외 포름안데히드 농도에 관한 조사연구 (Indoor and Outdoor Formaldehyde Concentrations in Underground Environments)

  • 김윤신;김미경
    • 한국환경보건학회지
    • /
    • 제15권2호
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

대전지역 지하상가의 대기오염도에 관한 조사연구 (A Study on Air Pollution in the Underground Shopping Store of Taejon Area)

  • 양천회;류완호;장철현
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.134-139
    • /
    • 1994
  • In order to assess the level of atmospheric pollution and to contribute the hearth improvement of residents in Taejon city, the authors were measured the concentration of air pollutants(CO, SO$_2$, NO$_2$, TSP, Pb, Cd, Cr) at three places of the control road in Taejon. The investigative research performed bimonthly from May 1993 to September 1993, and the places were the underground shopping stores of Taejon station, Dongyang department store and provincial goverment areas. The results of statistical analysis are as followings. \circled1CO :0.569~0.966ppm \circled2SO$_2$:0.084~0.170ppm \circled3NO$_2$:0.0045~0.022ppm \circled4TSP:249~299$\mu\textrm{g}$/㎥. \circled5Pb :0.366~1.157$\mu\textrm{g}$/㎥. \circled6Cd:0.016~0.025$\mu\textrm{g}$/㎥. \circled7 Cr : 0.198 ~0.290$\mu\textrm{g}$/㎥. The mean concentration of SO$_2$in Dongyang department store area was 0.17ppm, and it exceeded the ambient air quality standard by 0.02ppm. The concentration of TSP was higher than a standing rule of public hygiene, and it was very near to a standing rule of environmental preservation. The standing rule of indoor air pollution in underground shopping store have two different laws, the public hygiene and the environmental preservation. Therefore, it was difficult to judge what to do in such circumstance. In regarding to the laws, an environmental standard for air pollution in the underground space must unify into the standard of public hygiene.

  • PDF

다가구주택 반지하세대의 실내공기질 실태 및 영향요인 분석 (An analysis of the Influencing Factors and Actual State of Indoor Air Quality in Semi-underground Multi-family Housing Units)

  • 최윤정;김선영;김지영;최솔지
    • 한국생활과학회지
    • /
    • 제20권5호
    • /
    • pp.1075-1091
    • /
    • 2011
  • The purposes of this study were to investigate the actual state of indoor air quality in semi-underground multi-family housing units in early summer, to analyze the influencing factors, and to make suggestions for improvement. A series of field investigations were conducted in four target units between June 22, 2010, and June 28, 2010. The field investigations included measurements of indoor air quality as well as the observation of architectural characteristics and living conditions. In addition to the field investigation, on-site questionnaire surveys were administrated to residents in 90 units. The findings are summarized as follows: (1) The average $CO_2$ levels in each of the four units ranged from 759ppm to 1885ppm. $CO_2$ levels in three units exceeded the evaluation standard (1000ppm), and one unit was lower than the standard. This unit had smaller number of staying person and a large amount of ventilation than others; (2) the average CO levels in each unit were almost 0ppm, but 0.1~1.1 levels of CO were revealed at several times; (3) the average PM-10 levels ranged from $8{\mu}g/m^3$ to $40{\mu}g/m^3$, which distributes within the standard ($150{\mu}g/m^3$). The influencing factors of PM-10 levels were analyzed as inflow from outside, the use of a gas range, and the residents' activities; (4) therefore, it was evaluated to be necessary to improve ventilation for the indoor air quality of semi-underground housing in aspect of $CO_2$ levels.

지하상가 근무자의 건강 장애에 관한 실태조사 (Sick Building Syndrome in 130 Underground Workers)

  • 주리;사공준;정종학;박상환;김동희;김동민;최은경;조현근
    • Journal of Yeungnam Medical Science
    • /
    • 제15권2호
    • /
    • pp.325-340
    • /
    • 1998
  • 대구의 경우 최근 지하철의 개통과 더불어 대규모 지하상가가 건설 중에 있어 지하공간 근무자의 급속한 증가가 예상되며 이에 따른 보건학적인 문제에 관한 관심과 준비가 필요하다. 이 연구는 지하상가를 중심으로 지하공간 근무자들의 건강 양상을 파악하고 지하공간 실내공기의 오염원을 추정함으로써 지하공간 생활자의 보건학적인 문제점을 규명하고 대책을 세우기 위한 자료로 활용하기 위하여 이루어졌다. 1998년 8월에 대구 중앙지하상가 근무자 130명과 대명동 지역 지상상가 근무자 60명을 대상으로 미국 국립산업안전보건원에서 개발한 실내공기오염 설문지를 이용하여 건강 및 증상(예; 천식, 알레르기질환 이환여부, 눈, 코, 목, 호흡기, 피부 동의 비특이적 증상 등), 근무환경에 관한 사항(예; 환기, 온도, 습도, 냄새 등) 및 개인적인 사항(예; 연령, 성별, 흡연유무 등)을 조사하였다. 실내공기질의 측정은 지하상가를 6개 구역으로 나누고 구역별 온도, 산소, 이산화탄소, 일산화탄소와 포름알데히드를 측정하고 기존자료를 활용하였다. 대조군에 비해 지하상가에서 근무하는 고위험군은 기관지염과 먼지알레르기를 경험한 율이 유의하게 높였다. SBS의 진단기준은 NIOSH의 기준과 동일한 지난 한 달 동안 일주일에 하루 이상 눈, 코, 목, 호흡기 동의 증상과 두통, 피로감을 한가지 이상 경험하였고 지하공간을 벗어나면 증상이 호전되는 경우로 하였다. 지난 한달 동안 경험한 증상에 관한 조사에서 눈이 건조하다, 가렵다, 따갑다, 목이 따갑거나 건조함을 느낀다, 가슴이 답답하다, 눈이 피곤하고 충혈된다 및 피부가 가렵다, 건조하다 항목에서 두 군의 유병률은 유의한 차이가 있었다. 18개의 SBS 증상 중 1주일에 1-3회 이상 경험하는 증상의 개수는 고위험군에서 대조군에 비해 유의하게 많았다. 이상의 조사 및 분석결과를 종합하면 일부 지하상가 근무자들은 지하의 제한된 공간에 장기간 근무함으로써 부적절한 인간공학적 환경, 물리적 환경, 부족한 환기량 등에 의해 실내공기 오염으로 인한 증상 경험이 대조군에 비해 유의하게 높았으며 68.5%의 지하상가 근무자가 SBS를 경험하고 있었다. 그러므로 지하공간 근무자의 SBS 발생을 예방하기 위해서는 실내공기질의 정확한 평가를 통한 예방대책 수립이 필요하다. 또 의료인의 관심을 통해 SBS의 진단, 치료 및 예방 등과 같은 적절한 의학적 조치 및 연구가 이루어져야겠으며 근무자들의 환경에 대한 교육이 필요하다고 생각된다.

  • PDF

농수산물 및 식품의 지하 저장 (Underground Storage of Food)

  • 신희순;권광수
    • 터널과지하공간
    • /
    • 제4권2호
    • /
    • pp.192-200
    • /
    • 1994
  • Underground offers many advantages for storing agricultural and marine products. Since it is confined by thick walls of rock it is easy to control temperature and humidity and to achieve air and water tightness. Also, damages by rodents and insects could be avoided. Flexibility in choosing the location is another advantage that underground could offer. Consequently the goods could be stored near the big city to meet the demand change. Because of these advantages, many underground food storage facilities were built and operated successfully in U.S. and many Euroupean countries. On the other hand, there is no underground food storage facilities in Korea despite the need is growing rapidly. This paper describes the case studies of foreigh food storage and technologies related to food storage were analyzed and evaluated. Also performed is analysis of domestic technologies for construction and operation of underground food storage facilities to deduce the fields of studies that have to be conducted.

  • PDF

양돈용 지열교환기의 개발 (Construction of an Underground Heat Exchanger for Pig Housing)

  • 오인환;김일수
    • 한국축산시설환경학회지
    • /
    • 제1권2호
    • /
    • pp.125-136
    • /
    • 1995
  • 항온층 지열을 이용하는 지열교환기를 개발하여 겨울철의 난방효과와 여름철과 환절기에 있어서 온습도변화를 분석하였다. 또한 지열교환기가 매설된 토양의 종류는 미사질토로 나타났다. 시험한 결과를 요약하면 다음과 같다. 1. 디지탈풍속계를 사용하여 2월 중 하루동안의 온습도를 측정해 본 결과 입기의 온도가 -7.3$^{\circ}C$에서 6.4$^{\circ}C$의 변화를 보일 때 배기의 온도는 1.2~7.3$^{\circ}C$로 영상의 기온을 나타내었으며, 최대의 온도차 $\Delta$t는 8.5$^{\circ}C$이었다. 난방성능은 최대 3.25Wh/㎥이었으며, 평균 1.7Wh/㎥이었다. 2. 3월과 4월의 온도변화를 측정해 본 결과 땅속 2.5m의 온도와 지하배관내의 공기온도가 모두 10~l2$^{\circ}C$의 일정한 온도범위를 보여 외기의 급격한 온도와는 상관없이 변화폭이 적은 온도의 공기를 축사내로 공급할 수 있었다. 3. 7월 1일부터 5일까지의 온도변화 자료를 분석해 본 결과 지하 2.5m의 온도가 18~2$0^{\circ}C$의 일정한 범위를 보여 지난 3, 4월과 비교하여 지온이 약 8$^{\circ}C$ 정도 상승하였다. 4. 9월 중 일교차가 가장 심했던 9월 19일에서 22일 사이에 입기구와 배기구에서 순간온도변화를 측정한 결과 입기구에서 온도변화는 9~28$^{\circ}C$로 약 19$^{\circ}C$의 온도차를 보였으나 배기구에서의 온도변화는 15~$25^{\circ}C$의 범위를 보여 입기구의 온도변화에 비해 약 9$^{\circ}C$ 정도의 온도차로 완화할 수 있었다. 이상의 시험결과에서 나타난 바와 같이 지열교환기는 축사의 난방 보조열원으로서 양호한 열효율을 나타내어 우리나라 축사시설에 적용가능성을 제시하였다. 본 지열교환기 시스템은 지열을 이용하는 환경보전형 에너지 시스템으로서 시설하기 간편하고 경제적이며 반영구적인 냉난방 및 환기시스템이다. 따라서, 우리나라 축산시설에 실용화될 경우에 우수한 대체에너지원으로 에너지 절감효과에도 크게 기여하리라고 전망된다.

  • PDF