• Title/Summary/Keyword: under-water frequency

Search Result 464, Processing Time 0.03 seconds

Studies on the Consumptive Use of Irrigated Water in Upland (田作物 水分消費量 調査 硏究)

  • Kim, Shi-Won;Lee, Kyong-Hi;Doh, Duk-Hyun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.2
    • /
    • pp.47-58
    • /
    • 1984
  • The study results of the mosture consumption character and irrigation effect of tomato, red pepper and chinese cabbage, in case the soil moisture is kept with different moisture content by the soil properties(loam, sandy loam, sand), are summarized as follows: 1. The available rainfall under bare soil condition had an order of sand>sandy loam> loam and their average was 64.2%. 2. Total moisture consumption under bare soil condition had an order of loam>sandy loam>sand and their average was 4.2mm. 3. The amount of irrigated water to keep certain soil moisture under bare soil condition showed minimum in sand and maximum in loam. It is considered because the capillary phenomenon was more developed in loam. 4. Total moisture consumption of tomatoes under premature cultivation showed 925mm in maximum and had on order of loam>sandy loam>sand. In the aspect of re-irrigation point, it had an order of PF 1.5> PF 1.7>PF 2.1. In case the twenty years's drought frequency was taken into account, the target amount of irrigation water meeded for premature cultivation was 916mm and its average daily moisture consumption was 10.8mm. 5. Total moisture consumption of red pepper under open cultivation showed 1145mm in maximum and had an order of loam>Sandy loam>sand. In the aspect of re-irrigation frequency was taken into consideration the target amount of irrigation water was 1,174.8mm and its average daily moisture consumption was 8.0mm. 6. Total moisture consumption of autumn chinese cabbages was 349mm in maximum and had an order of loam>sandy loam>sand. In the aspect of re-irrigation point, it had an order of PF 1.5>PF 2.1>PF 2.7. In case the twenty year's drought frequency was taken into account, the target amount of irrigation water needed for chinese cabbage cultivation was 259.5mm and its average daily moisture consumption was 6.5mm. 7. It is effective to keep the soil moisture of tomato from PF 1.5 to PF 2.1 in loam and the soil moisture control was effective in sandy loam than red pepper and chinese cabbage. In sand, the production was severaly decreased and the re-irrigation point of PF 1.5 was effective.

  • PDF

An overview and update on Rainfall Intensity Duration Frequency (IDF) and Flood Estimation work in the Asia Pacific Region

  • Jamieson, Dennis
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2210-2214
    • /
    • 2009
  • This paper summarizes progress on work under the Asian Pacific FRIEND(Flow Regimes from International Experimental and Network Data - APFRIEND) initiative of the International Hydrological Programme (IHP) of the United Nations Educational, Scientific and Cultural Organisation (UNESCO) from 2005 to 2009. The results of initial work on Rainfall Intensity Duration Frequency (IFD) have just been published as a volume by UNESCO. The results of work to date is concisely presented and observations made about lessons learnt on how to successfully integrate work from nine diverse countries with differing approaches to both hydrology and water resource management structures and on some possible directions for future work.

  • PDF

On Dynamic Voltage Scale based Protocol for Low Power Underwater Secure Communication on Sensor Network (센서 네트워크 상에서의 저전력 보안 수중 통신을 위한 동작 전압 스케일 기반 암호화에 대한 연구)

  • Seo, Hwa-Jeong;Kim, Ho-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.586-594
    • /
    • 2014
  • Maximizing the operating time by reducing the power consumption is important factor to operate sensor network under water networks. For efficient power consumption, dynamic voltage scaling method is available. This method operates low frequency when there is no workload. In case of abundant workload, high frequency operation completes hard work within short time, reducing power consumption. For this reason, complex cryptography should be computed in high frequency. In this paper, we apply dynamic voltage scaling method to cryptography and show performance evaluation. With this result, we can reduce power consumption for cryptography in under water communication.

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

Development of Induction Heated Hot Water Producer using Soft Switching PWM High Frequency Inverter

  • Fujita Kentarou;Moisseev Serguei;Gaimage Laknath;Chandhaket Sarawouth;Muraoka Hidekazu;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.491-494
    • /
    • 2003
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or Dual Packs Heater in hot water producer, boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, all active clamped edge resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle oi zero voltage soft communication with PWM is developed and demonstrated for a high efficient Induction heated hot water producer and boiler in the consumer power applications. This consumer induction heater power appliance using active clamp soft switching PWM high frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Buckling and Vibration Characteristics of the Capsule for Nuclear Fuel Irradiation Test (핵연료 조사시험용 캡슐 구조물의 좌굴 및 진동특성)

  • 강영환;김봉구;류정수;김영진;최명환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.125-130
    • /
    • 2004
  • The vibration and buckling characteristics of the capsule for fuel irradiation test are studied. The natural frequencies of the capsule in air and under water are obtained by modal testing and finite element(FE) analysis using ANSYS program, and accelerations with flow are measured to estimate the compatibility with the operation requirement of the HANARO reactor. The experimental fundamental frequency of the capsule in the x and z direction is 8.5Hz and 8.75Hz in air, and 7.5Hz and 7.75Hz under water, respectively. The maximum amplitude of accelerations under the normal operating condition is measured as 11.0m/s$^2$ that is within the allowable vibrational limit(18.99m/s$^2$) of the reactor structure. Also, the maximum displacement at 100% flow is calculated as 0.13mm which is not interference with other nearby structures. FE analysis results show that the natural frequencies are found to be similar to those of the modal testing when three supporting parts are considered as simply supported conditions. From the buckling analysis, when the loading tool is applied, the critical buckling load of the capsule is 233N.

  • PDF

Irrigation Frequency and Nitrogen Rates for Tall Fescue Growth

  • Lee, Sang-Kook
    • Weed & Turfgrass Science
    • /
    • v.3 no.2
    • /
    • pp.130-136
    • /
    • 2014
  • Tall fescue is commonly well-adapted for low maintain area because of its wear resistance, deep root system, and drought tolerances. Deep and infrequent irrigation refers to applying large amounts of irrigation, 1.3 to 2.5 cm or more, in a single irrigation event. Light and frequent irrigation is commonly used with small amounts of water, 0.3 to 0.6 cm, every day or every other day. N use for turfgrass management is often unnoticed for water management. The objective of this field study was to evaluate the effects of irrigation frequency and N rates for tall fescue growth. The three irrigation treatments were no irrigation (precipitation only), 0.5 cm applied every other day, and 1.8 cm applied once a week at one irrigation event. The nitrogen (N) treatments were the low, medium, and high N rate treatments. The low, medium, and high N treatments were applied over 2, 4, and 6 applications, respectively. If high main maintenance of tall fescue is not important and water source is limited, irrigation is not necessary and, the $9.8gNm^{-2}yr^{-1}$ of two applications can be recommended for tall fescue under the weather condition of the study.

The timing of unprecedented hydrological drought under climate change

  • Yusuke Satoh;Hyungjun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.48-48
    • /
    • 2023
  • The intensified droughts under climate change are expected to threaten stable water resource availability. Droughts exceeding the magnitude of historical variability could occur increasingly frequently under future climate conditions. It is crucial to understand how drought will evolve over time because the assumption of hydrological stationarity of the past decades would be inappropriate for future water resources management. However, the timing of the emergence of unprecedented drought conditions under climate change has rarely been examined. Here, using multimodel hydrological simulations, we investigate the changes in the frequency of hydrological drought (defined as abnormally low river discharge) under high and low greenhouse gas concentration scenarios and with existing water resources management and estimate the timing of the first emergence of unprecedented regional drought conditions that persist for over several consecutive years. This new metric enables a new quantification of the urgency of adaptation and mitigation with regard to drought under climate change. The times are detected for several sub-continental-scale regions, and three regions, namely, southwestern South America, Mediterranean Europe, and northern Africa, exhibit particularly robust and earlier critical times under the high-emission scenario. These three regions are expected to confront unprecedented conditions within the next 30 years with a high likelihood, regardless of the emission scenarios. In addition, the results obtained herein demonstrate the benefits of the lower-emission pathway in reducing the likelihood of emergence. The Paris Agreement goals are shown to be effective in reducing the likelihood to the unlikely level in most regions. Nevertheless, appropriate and prior adaptation measures are considered indispensable to when facing unprecedented drought conditions. The results of this study underscore the importance of improving drought preparedness within the considered time horizons.

  • PDF

A computer based simulation model for the fatigue damage assessment of deep water marine riser

  • Pallana, Chirag A.;Sharma, Rajiv
    • Ocean Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.87-142
    • /
    • 2022
  • An analysis for the computation of Fatigue Damage Index (FDI) under the effects of the various combination of the ocean loads like random waves, current, platform motion and VIV (Vortex Induced Vibration) for a certain design water depth is a critically important part of the analysis and design of the marine riser platform integrated system. Herein, a 'Computer Simulation Model (CSM)' is developed to combine the advantages of the frequency domain and time domain. A case study considering a steel catenary riser operating in 1000 m water depth has been conducted with semi-submersible. The riser is subjected to extreme environmental conditions and static and dynamic response analyses are performed and the Response Amplitude Operators (RAOs) of the offshore platform are computed with the frequency domain solution. Later the frequency domain results are integrated with time domain analysis system for the dynamic analysis in time domain. After that an extensive post processing is done to compute the FDI of the marine riser. In the present paper importance is given to the nature of the current profile and the VIV. At the end we have reported the detail results of the FDI comparison with VIV and without VIV under the linear current velocity and the FDI comparison with linear and power law current velocity with and without VIV. We have also reported the design recommendations for the marine riser in the regions where the higher fatigue damage is observed and the proposed CSM is implemented in industrially used standard soft solution systems (i.e., OrcaFlex*TM and Ansys AQWA**TM), Ms-Excel***TM, and C++ programming language using its object oriented features.

Numerical investigation of film boiling heat transfer on the horizontal surface in an oscillating system with low frequencies

  • An, Young Seock;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.918-924
    • /
    • 2020
  • Film boiling is of great importance in nuclear safety as it directly influences the integrity of nuclear fuel in case of accidents involving loss of coolant. Recently, nuclear power plant safety under earthquake conditions has received much attention. However, to the best of our knowledge, there are no existing studies reporting film boiling in an oscillating system. Most previous studies for film boiling were performed on stationary systems. In this study, numerical simulations were performed for saturated film boiling of water on a horizontal surface under low frequencies to investigate the effect of system oscillation on film boiling heat transfer. A coupled level-set and volume-of-fluid method was used to track the interface between the vapor and liquid phases. With a fixed oscillation amplitude, overall, heat transfer decreases with oscillation frequency. However, there is a frequency region in which heat transfer remains nearly constant. This lock-on phenomenon occurs when the oscillation frequency is near the natural bubble release frequency. With a fixed oscillation frequency, heat transfer decreases with oscillation amplitude. With a fixed maximum amplitude of the additional gravity, heat transfer is affected little by the combination of oscillation amplitude and frequency.