• Title/Summary/Keyword: unbalanced model

Search Result 287, Processing Time 0.026 seconds

Compensation of Unbalanced Neutral Voltage for Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS Using Offset Voltage (오프셋 전압을 이용한 계통 연계형 3상 3레벨 T-type 태양광 PCS의 중성점 전압 불평형 보상)

  • Park, Kwan-Nam;Choy, Ick;Choi, Ju-Yeop;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.1-12
    • /
    • 2017
  • The DC link of Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS (PV-PCS) consists of two series connected capacitors for using their neutral voltage. The mismatch between two capacitor characteristics and transient states happened in load change cause the imbalance of neutral voltage. As a result, PV-PCS performance is degraded and the system becomes unstable. In this paper, a mathematical model for analyzing the imbalance of neutral voltage is derived and a compensation method using offset voltage is proposed, where offset voltage adjusts the applying time of P-type and N-type small vectors. The validity of the proposed methods is verified by simulation and experiment.

Dynamic Characteristics of Moving Coil Linear Oscillatory Actuator Considering the Variable Inductance and Push/pull Effects (가동차 위치에 따른 인덕턴스 변화와 Push/Pull 효과를 고려한 가동코일형 LOA의 동특성)

  • Jeong, Sang-Sub;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.307-314
    • /
    • 2001
  • A moving coil linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The variation of mover position and the consequent changes of coil flux path affect the coil inductance, because coil flux leaks at the open region of LOA stator. The interaction between permanent magnet and armature field is to shift the airgap flux density variation due to the magnet alone by a certain amount. The unbalanced reciprocation force due to armature reaction field decreases the advantage of moving coil LOA, such as a high degree of linearity and controllability in the force ad motion control. This paper firstly describes the coil inductance, the deviation of flux density, and the unbalanced reciprocation force, which are derived form the permeance model of LOA. Secondly, the analytical method are verified using the 2D finite element method and tests. Finally, the dynamic simulation algorithm taking the armature reaction effect and variable inductance into account, is proposed and confirmed through the experiment.

  • PDF

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

An Experimental Study on the Non-Uniform Flow Distribution in the Windbox of an Oil-Fired Boiler (유류 연소 발전용 보일러에서 공기 공급 계통의 불균일성에 관한 실험적 연구)

  • Go, Young-Gun;Kim, Young-Zoo;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Oil-fired power plant usually uses several burners and combustion air is supplied to each burner through the complicated duct which is called windbox. A windbox should be designed to supply combustion air to each burner uniformly but, due to the complicated duct shape, flow distribution in the windbox is unbalanced and non-uniform supplies of combustion air are induced by these unbalanced flows in the windbox. These flow patterns tend to make flame unstable, increase the formation of pollutants and lower the overall combustion efficiency. To prevent these disadvantages, flow patterns in the windbox should be investigated for the uniform flow distribution. In this study, computational simulation method was used to investigate the flow distribution in a windbox and measured the velocities at the exit of burners in a real windbox and model tests to compare with CFD results. The results show two significant flow patterns. One is that the flow rates of each burner are different from each other and this means that all burners operate in different conditions of air to fuel ratio. The other is that the flow distribution at the exit of each burner is not axi-symmetric although the burner shape is axi-symmetric. Additionally some modifications of windbox shape and installation of baffles were proposed to make the uniform flow in the windox.

  • PDF

A New Distribution System Power Flow Method Using Symmetrical Components (대칭성분을 이용한 3상 배전계통 조류계산 기법)

  • Choe, Jeong-Hwan;Jeong, Seong-Il;Park, Je-Yeong;Kim, Gwang-Ho;Kim, Jae-Eon;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

An Anti-vibration Design of Slim-type Optical Disk Drive (슬림형 광 디스크 드라이브의 방진설계)

  • Kim, Nam-Woong;Kim, Kug-Weon;Hong, Goo;Chung, Mun-Chae;Kim, Wae-Yeul
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.324-330
    • /
    • 1999
  • With the increase of track density, high rotational speed and the compatibility for various media such as CD-ROM, CD-R/RW, DVD-ROM/RAM/RW etc. in optical disk drive, the effective anti-vibration design is so crucial for robust operaton. Especailly when the drive is self-excited by unbalanced disk, internal sled base vibration and its external transmission to the case bring about so severe problem. Generally these two consideration points the practical anti-vibration design process to control thses two conflictive properties using finite element analysis. As an example of the design process, Duro 25 and 40 visco-elastic rubber mount was selected and analyzed. The stiffness obtained from FEM rubber model was well matched with the experiments. Also it was confirmed that the internal and external vibration induced from unbalanced disk have good agreement with experimental results. The proposed design process is adopted to the slim-type optical disk drive.

  • PDF

ID-based Authenticated Key Agreement for Unbalanced Computing Environment (비대칭 컴퓨팅 환경을 위한 ID-기반의 인증된 키 동의 프로토콜)

  • Choi Kyu-young;Hwang Jung-yeon;Hong Do-won;Lee Dong-hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.1
    • /
    • pp.23-33
    • /
    • 2006
  • Key Agreement protocols are among the most basic and widely used cryptographic protocols. In this paper we present an efficient O-based authenticated key agreement (AKA) protocol by using bilinear maps, especially well suited to unbalanced computing environments : an ID-based AKA protocol for Server and Client. Particularly, considering low-power clients' devices, we remove expensive operations such as bilinear maps from a client side. Our protocol uses signcryption and provide security in random oracle model.

A Syudy On DVR Control for Unbalanced Voltage Compensation (불평형 전압 보상을 위한 DVR 제어에 관한 연구)

  • Jung, Hong-Ju;Chung, Joon-Mo;Song, Jong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.218-221
    • /
    • 2001
  • This paper presents a new control scheme for a Dynamic Voltage Restorer(DVR) system consisting of series voltage source PWM converters. The control system is designed using differential controllers and digital filters to transfer the faulted ac source voltage to a d-q model and to separate the positive and negative sequence component for individual compensation. The performance of the presented controller and scheme are confirmed through simulation and actual experiment.

  • PDF

Unbalanced Power System Analysis in Railroad System Using PSCAD/EMTDC (철도 시스템의 불평형 해석을 위한 EMTDC 모델링)

  • Lee, Han-Sang;Lee, Han-Min;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.236-238
    • /
    • 2003
  • This paper proposes a method for estimating unbalance in electric railroad system PSCAD/EMTDC models for voltage unbalance analysis of electric railroad system that transfer electric power through Scott transformer from KEPCO's 154kV transmission line are developed. In order to verify model's validity, we compare simulation results with simple calculation results.

  • PDF