• 제목/요약/키워드: ultrasound volume data

검색결과 32건 처리시간 0.029초

Estimates of Genetic Correlations between Production and Semen Traits in Boar

  • Oh, S.H.;See, M.T.;Long, T.E.;Galvin, J.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권2호
    • /
    • pp.160-164
    • /
    • 2006
  • Currently, boars selected for commercial use as AI sires are evaluated on grow-finish performance and carcass characteristics. If AI sires were also evaluated and selected on semen production, it may be possible to reduce the number of boars required to service sows, thereby improving the productivity and profitability of the boar stud. The objective of this study was to estimate genetic correlations between production and semen traits in the boar: average daily gain (ADG), backfat thickness (BF) and muscle depth (MD) as production traits, and total sperm cells (TSC), total concentration (TC), volume collected (SV), number of extended doses (ND), and acceptance rate of ejaculates (AR) as semen traits. Semen collection records and performance data for 843 boars and two generations of pedigree data were provided by Smithfield Premium Genetics. Backfat thickness and MD were measured by real-time ultrasound. Genetic parameters were estimated from five four-trait and one five-trait animal models using MTDFREML. Average heritability estimates were 0.39 for ADG, 0.32 for BF, 0.15 for MD, and repeatability estimates were 0.38 for SV, 0.37 for TSC, 0.09 for TC, 0.39 for ND, and 0.16 for AR. Semen traits showed a strong negative genetic correlation with MD and positive genetic correlation with BF. Genetic correlations between semen traits and ADG were low. Therefore, current AI boar selection practices may be having a detrimental effect on semen production.

공학교육 빅 데이터 분석 도구 개발 연구 (Research on the Development of Big Data Analysis Tools for Engineering Education)

  • 김윤영;김재희
    • 공학교육연구
    • /
    • 제26권4호
    • /
    • pp.22-35
    • /
    • 2023
  • As information and communication technology has developed remarkably, it has become possible to analyze various types of large-volume data generated at a speed close to real time, and based on this, reliable value creation has become possible. Such big data analysis is becoming an important means of supporting decision-making based on scientific figures. The purpose of this study is to develop a big data analysis tool that can analyze large amounts of data generated through engineering education. The tasks of this study are as follows. First, a database is designed to store the information of entries in the National Creative Capstone Design Contest. Second, the pre-processing process is checked for analysis with big data analysis tools. Finally, analyze the data using the developed big data analysis tool. In this study, 1,784 works submitted to the National Creative Comprehensive Design Contest from 2014 to 2019 were analyzed. As a result of selecting the top 10 words through topic analysis, 'robot' ranked first from 2014 to 2019, and energy, drones, ultrasound, solar energy, and IoT appeared with high frequency. This result seems to reflect the current core topics and technology trends of the 4th Industrial Revolution. In addition, it seems that due to the nature of the Capstone Design Contest, students majoring in electrical/electronic, computer/information and communication engineering, mechanical engineering, and chemical/new materials engineering who can submit complete products for problem solving were selected. The significance of this study is that the results of this study can be used in the field of engineering education as basic data for the development of educational contents and teaching methods that reflect industry and technology trends. Furthermore, it is expected that the results of big data analysis related to engineering education can be used as a means of preparing preemptive countermeasures in establishing education policies that reflect social changes.

초음파 데이터에서 실시간 잡음 감쇄를 이용한 광선 투사법 (Volume Ray Casting for Ultrasound Data Using Real-Time Noise Reduction)

  • 서강희;권구주;신병석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2005년도 춘계학술발표대회
    • /
    • pp.1623-1626
    • /
    • 2005
  • 초음파 영상 기법은 장기, 연조직, 혈류를 검사하는데 쓰이는 영상 진단법이다. 초음파 장비를 통해 얻어진 초음파 볼륨 데이터는 장비 특성상 많은 잡음(speckle noise)을 포함하기 때문에, 깨끗한 영상을 얻기 위해서는 잡음 필터링(noise filtering)이 필요하다. 그런데, 볼륨 데이터 모든 영역에 대해 잡음 필터링을 적용할 경우 전처리 시간이 길어져 실시간으로 초음파 볼륨 데이터를 렌더링하기 어렵다. 본 논문에서는 실시간으로 입력되는 초음파 볼륨 데이터를 가시화 하기위하여 전처리 시간 없이 잡음을 제거하는 방법을 제안한다. 전처리 시간에 전체 볼륨 데이터에 대해 잡음 필터링을 적용하지 않고, 영상을 생성하는 동안 참조되는 복셀(voxel)에 대해서만 잡음 필터를 적용하여 얻은 값을 사용한다. 이때 필터링에 소요되는 시간을 최소화하기 위해 가장 단순한 평균화 필터를 사용한다. 그리고 복셀에 적용되는 3차원 필터를 3단계의 1차원 필터 연산 단계로 분할 한 후, 각 단계별 연산을 거친 복셀들에 대해서는 다시 연산을 하지 않도록 하여 중복을 피한다. 이를 통해 전처리 시간 없이 기존 방법과 동일한 화질을 유지하는 최종 영상을 만들어 낸다.

  • PDF

스펙클 패턴의 통계적 평균과 엔트로피 방식에 의한 초음파 감쇄계수 추정방법 (Attenuation Estimation of Soft Tissue by the Entropy Method and Statistical Averaging of Speckle Patterns)

  • 송태경;박종철;박송배
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.253-260
    • /
    • 1989
  • 시간 영역에서의 초음파 강쇄계수 추정방법은 일반적으로 감쇄매절을 통과하면서 반사된 초음파 신호의 통계적인 특성의 해석을 기초로 한다. 따라서 선뢰할 수 있는 추정결과를 얻기 위해셔는 대게 충분히 많은 초음파 신호의 샘플을 펼요로 하게 된다. 감쇄계수를 추정하는 문제에 있어서, 이것은 감쇄계수 영상의 공간 해상도 체적내에서 통계적으로 다른 특성을 갖는 많은 스렉클 패턴이 필요하다는 것을 의마한다. 이 논문에서는 스펙클 패턴이 초음파 빔의 정확산함수에 따라 다른 통계적인 특성을 갖는다는 성질을 이용하여 초음파 선행변환자플 회전시키면서 각 회전각도에서 측방향 스캔을 함으로써 통계적 상관이 적은 다수의 샘플틀을 얻는 방법을 제안하였다. 이 방법은 최근에 우리가 제안한초음파 감쇄계수의 추정을 위한 엔트로피 방법과 결합되어 감쇄계수추정의 정확성을 증가시카고 공간해상도를 줄얼 수 있다. 인체의 연조직과 유사한 특성을 갖는 팬텀을 제작한 후 실험을 통하여 제안한 방법의 타당성을 검증하도록 하겠다.

  • PDF

전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구 (The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis)

  • 황성일;이학종;김길중;정진행;정현숙;전종준
    • Ultrasonography
    • /
    • 제32권2호
    • /
    • pp.132-142
    • /
    • 2013
  • 목적: 전립선암 (PC-3, LNCaP)의 이종이식쥐 모델에서 초음파 조영제를 이용하여 측정한 시간-신호강도 곡선을 통해 얻은 역학적 변수를 조직병리적 변수와 비교하고자 하였다. 대상 및 방법: 20마리의 누드마우스에 인간전립선암세포(15 PC-3, 5 LNCaP)를 다리에 주입하여 이종이식쥐 모델을 제작하였다. 이후 $500{\mu}L$의 2세대 초음파 조영제인 Sonovue를 후안와정맥을 통해 주입하였다. 관심영역은 종양의 전체를 포함할 수 있게 그린 후, 시간-신호강도 곡선을 얻고 이를 감마변량함수에 적합시켰다. 최고신호강도(A), 최고도달시간 (Tp), 최고유입률 (washin), 최고 유출률 (washout), 50초까지의 곡선하면적 ($AUC_{50}$), 유입기면적 ($AUC_{in}$), 유출기면적 ($AUC_{out}$) 등을 감마변량함수에서 도출하였다. VEGF와 CD31에 대한 면역조직화학염색법을 시행하였고, 종양부피, 시야당 VEGF 면적백분율, CD31 양성 미세혈관수 (MVD) 등을 계산한 후 이를 시간신호강도에서 얻은 역학적 변수와 상관성을 조사하였다. 결과: PC-3 와 LNCaP간 동적 및 조직병리학적 변수의 통계적 차이는 없었다. MVD는 A (r=0.625, p=0.003), washin (r=0.462, p=0.040), AUC (r=0.604, p=0.005), $AUC_{out}$ (r=0.587, p=0.007) 과 유의한 상관관계를 보였다. 또한 종양부피와 $AUC_{50}$ (r=0.481, p=0.032), washin(r=0.662, p=0.001), $AUC_{out}$ (r=0.547, p=0.012) 도 유의한 양의 상관관계를 보였으며, washout은 MVD (r=-0.454, p=0.044) 및 종양부피 (r=-0.464, p=0.039)에 모두 음의 상관관계를 보였다. 그러나 시야당 VEGF 면적백분율은 역학적 변수와 유의한 상관관계를 보이지 않았다. 결론: MVD는 다수의 역학적 변수와 상관관계를 보였다. 초음파 조영제를 이용한 초음파는 전립선암 동물모델에서 종양의 혈관성을 예측할 수 있는 가능성을 보였다.

간헐적 양압호흡기를 이용한 호흡운동치료 후 근 이영양증 환자의 폐기능 변화 (Changes in Pulmonary Functioning After Respiratory Excercise Treatment in Patients With Progressive Muscular Dystrophy)

  • 김기송;이규완;오덕원
    • 한국전문물리치료학회지
    • /
    • 제6권3호
    • /
    • pp.72-81
    • /
    • 1999
  • The purpose of this study was to identify the differences in pulmonary functioning after respiratory exercise with IPPB (Intermittent Positive Pressure Breather) in patients with progressive muscular dystrophy (PMD). The subjects were 46 patients with PMD who were admitted to the Rehabilitation Medicine Department of Youngdong Severance Hospital. The subjects were assigned into one of 2 groups. The control group received comprehensive treatments such as ROM exercise, deep breathing exercise, moist hot packs, and ultrasound twice a day while admitted at the Rehabilitation Medicine Department. Unlike the control group, the subjects at the experimental group received respiratory exercise treatment with IPPB. The subjects were admitted for 10~19 days, and the average length of hospital stay was 12.2 days. Pulmonary functioning was evaluated at admission and discharge by SENSOR MEDICS. The data were analyzed by a paired t-test and a independent t-test. The results were as follows: 1) The change of each parameter of pulmonary function tests were significantly improved in all groups after respiratory exercise treatment during admission (p<0.05). 2) By comparing the change of each parameter of pulmonary function tests between the experimental group and control group, the parameters of vital capacity (VC), forced vital capacity, forced vital capacity predicted (FVCP) and forced expiratory volume in 1 second (FEV1) were significantly improved in the experimental group which had received the pulmonary exercise treatment with IPPB (p<0.05). In conclusion, this study suggests that the pulmonary exercise treatments with IPPB facilitated improvement in the pulmonary functioning for the PMD patients during their hospital stay.

  • PDF

Evaluation of Inflammation Parameters in Philadelphia Negative Chronic Myeloproliferative Neoplasia Patients

  • Hacibekiroglu, Tuba;Akinci, Sema;Basturk, Abdulkadir;inal, Besime;Guney, Tekin;Bakanay, Sule Mine;Dilek, Imdat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권13호
    • /
    • pp.5159-5162
    • /
    • 2015
  • Background: Chronic myeloproliferative diseases are clonal stem cell diseases which occur as a result of uncontrollable growth and reproduction of hematopoietic stem cells, which are the myeloid series source in bone marrow. Recent studies have suggested that chronic inflammation can be a triggering factor in the clonal change in chronic myeloproliferative neoplasia (CMPN). In our study, we evaluated the existence of a chronic inflammation process in our Philadelphia negative (Ph-)CMPN patients using inflammation parameters in combination with demographic, laboratory and clinical characteristics of the patients. Materials and Methods: Demographic characteristics, clinical and laboratorial data, and thrombosis histories of 99 Ph-CMPN patients, who were diagnosed at our outpatient clinic of hematology in accordance with WHO 2008 criteria, were analyzed retrospectively,with 80 healthy individuals of matching gender and age included as controls. Complete blood counts, sedimentation, C reactive protein (CRP), JAK V617F gene mutations, abdomen ultrasound images and previous thrombosis histories of these patients were retrospectively analyzed. Results: Ph-CMPN and healthy control groups included 99 and 80 cases, respectively. PV, ET and MF diagnoses of patients were 43 (%43.4), 44 (44.4%) and 12 (12.1%), respectively. JAK V617F gene mutation was found to be positive in 64 (71.1%) of all cases and in 27(65.8%), 32 (82%), 5 (50%) of the cases in PV, ET and PMF groups, respectively. Thrombosis was determined as 12 (12%) in the entire group, 12.5% in the JAK V617F negative and 15.3% in the positive patients, with no statistical significance (p=0.758). No significant difference was observed between patients with and without previous thrombosis history in respect to hemogram parameters, sedimentation and CRP (p>0.05), neutrophil to lymphocyte ratio (NLR), erythrocyte distribution width (RDW), mean platelet volume (MPV) and sedimentation levels of the patient.

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권20호
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.316-324
    • /
    • 2004
  • 목적 : 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사 체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 대상 및 방법 : 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range $3\~3$ m), Computer (RS232C), Sewo Motor (Torque 2.3 Kg) 등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 결과 : 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}1\%$ 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 $2.34{times}10^{-4}$초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 결론 : 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}1\%$ 이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34H10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.