• 제목/요약/키워드: ultrasound imaging

검색결과 657건 처리시간 0.028초

만성 요통 환자의 상지 기능적 동작시 초음파에 나타나는 다열근의 변화 (Change of Lumbar Multifidus Muslce Recorded Simultaneously by Ultrasound Imaging during Upper Extremity Lifting Movement in Chronic Low Back Pain Patients)

  • 장원석
    • 대한물리의학회지
    • /
    • 제4권1호
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose : The purpose of this study is change of lumbar multifidus muslce recorded simultaneously by ultrasound imaging during upper extremity functional movement in chronic low back pain patients. The subject were consisted of 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women. Methods : 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women is voluntary participated for the research. Subjects were positioned in standing. Multifidus size were measured from L4 vertebral segement. The ultrasound imaging apparatus(Sonoace 6000, Medison, Korea) was epuipped with a 5-MHz convex array transducer. The upper extremity lifting movement used to activate the multifidus was then measured. Results : Results of the analysis showed that at the L4 vertebral leves, healthy asymptomatic subjects had significantly larger multifidus muscle compared with chronic LBP subjects. Conclusion : This study will be used as treatment method of patient with chronic LBP. The multifidus muscle in chronic LBP patients clinical significance. Most of chronic LBP patients have multifidus contraction pattern. Especially multifidus contraction in L4 vertebral segement. So chronic LBP patients necessary multifidus muscle release treatment.

  • PDF

초음파 영상에서 급성 위점막 병변으로 진단된 환자에 대한 한의치료 치험 1례 (A Case Report on Korean Medicine Treatment for a Patient Diagnosed with Acute Gastric Mucosal Lesion on Ultrasound Imaging)

  • 김채은;백태현
    • 대한한방내과학회지
    • /
    • 제44권6호
    • /
    • pp.1354-1361
    • /
    • 2023
  • Objectives: This study reports a clinical case that showed improvement in the symptoms of a patient with acute gastric mucosal lesion (AGML) through ultrasound. Methods: A 90-year-old woman with AGML was treated with Korean medicine treatments, including Hyangsapyeongwisan Soft Ext, acupuncture, and moxibustion. The responses before and after treatment were evaluated using ultrasound imaging and the numerical rating scale (NRS). Results: After treatment, ultrasound imaging showed improvement in gastric mucosa thickness, from 1.45 cm to 0.53 cm at the anterior wall and from 1.25 cm to 0.36 cm at the posterior wall. The NRS scores for epigastric pain, nausea, and dizziness all decreased, and the symptoms of diarrhea disappeared. Conclusion: This study suggests that Korean medicine treatment can be a therapeutic option in treating the symptoms of patients with AGML.

Magnetic Resonance Imaging of Placenta Accreta Spectrum: A Step-by-Step Approach

  • Sitthipong Srisajjakul;Patcharin Prapaisilp;Sirikan Bangchokdee
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.198-212
    • /
    • 2021
  • Placenta accreta spectrum (PAS) is an abnormal placental adherence or invasion of the myometrium or extrauterine structures. As PAS is primarily staged and managed surgically, imaging can only guide and facilitate diagnosis. But, imaging can aid in preparations for surgical complexity in some cases of PAS. Ultrasound remains the imaging modality of choice; however, magnetic resonance imaging (MRI) is required for evaluation of areas difficult to visualize on ultrasound, and the assessment of the extent of placenta accreta. Numerous MRI features of PAS have been described, including dark intraplacental bands, placental bulge, and placental heterogeneity. Failure to diagnose PAS carries a risk of massive hemorrhage and surgical complications. This article describes a comprehensive, step-by-step approach to diagnostic imaging and its potential pitfalls.

탄성 영상법 개발을 위한 유연성 높은 초음파 시스템의 구현 (Development of Flexible Ultrasound System for Elastography)

  • 김동인;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.32-38
    • /
    • 2012
  • Recently, several ultrasound imaging techniques for tissue characterization have been developed. Among them, ultrasound elastography is regarded as the most promising modality and has been rapidly developed. One of ultrasound elastography techniques is shear modulus imaging. Normal and cancerous tissues show big difference of shear moduli and they have good image contrast. However shear wave elastography requires more complicated hardware and more computations for image reconstruction algorithm. Therefore new efficient techniques are being developed. In this paper, we have developed a very flexible ultrasound system for elastography experiments. The developed system has capabilities to acquire ultrasound RF data of all channels and generate arbitrary ultrasound pulse sequences. It has a huge amount of memories for RF data acquisition and a simple and flexible pulse generator. We have verified the performance of the system showing conventional B-mode images and preliminary results of elastography. The developed system will be used to verify our own reconstruction algorithm and to develop more efficient elastography techniques.

광간섭 단층 영상기술을 이용한 생체 내 microneedle 삽입 구조 영상 (High-resolution imaging of microneedles in biological tissue with optical coherence tomography)

  • 김훈;허정;이강주;유수호;류원형;주철민
    • 정보저장시스템학회논문집
    • /
    • 제9권1호
    • /
    • pp.17-21
    • /
    • 2013
  • Optical coherence tomography (OCT) allows non-invasive, cross-sectional optical imaging of biological tissue with high spatial resolution and acquisition speed. In principle, it is analogous to ultrasound imaging, but uses near-infrared light instead of ultrasound, measuring the time-delay of back-scattered light from within biological tissue. Compared to ultrasound imaging, it exhibits superior spatial resolution (1~10 um) and high sensitivity. Therefore, OCT has been applied to a wide range of applications such as cellular imaging, ophthalmology and cardiology. Here, we describe a novel application of OCT technology in visualizing microneedles embedded in tissue that is developed to deliver drugs into the dermis without the injection mark in the human skin. Detailed three-dimensional structural images of microneedles and biological tissues were obtained. Examining structural modification of microneedles and tissues during insertion process would enable to evaluate performance of various types of microneedles in situ.

편측무시 환자에게 실시간 초음파 영상을 이용한 왼쪽 몸통 굽힘 패턴을 적용한 과제지향적 훈련의 효과 -단일 사례 연구- (The Effects of Task-Oriented Training for Left Trunk Flexion Pattern Using Real-Time Ultrasound Imaging -A Single-Subject Experimental Study-)

  • 김지선;기경일;강태우
    • PNF and Movement
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2019
  • Purpose: This study investigates the effects of task-oriented training for a left trunk flexion pattern using real-time ultrasound imaging in a stroke patient with unilateral neglect symptoms. Methods: This study used the ABA experimental design, which is a single-subject research method among individual case research methods. For the ABA experimental design, changes in the degree of unilateral neglect, balance ability, and the thickness of the lateral abdominal muscle were visually analyzed during the baseline process, in the intervention period, and after the intervention. The experiments were performed 24 times in total for 8 times in each of the 3 periods. The unilateral neglect was measured using the Albert test, balance ability was measured using the Berg balance test, and the thickness of the lateral abdominal muscle was measured using ultrasound imaging. The subject was a 50-year-old male patient with unilateral neglect caused by right cerebral hemorrhage. He performed task-oriented training for a voluntary left trunk flexion pattern using real-time ultrasound imaging during the intervention period. Results: The result of comparing the data collected during the intervention period with the data point average of the baseline process showed that balance ability improved and the tendency line was above the baseline. The tendency line of unilateral neglect was below the baseline and showed a decreasing tendency. The thickness of the lateral abdominal muscle showed an increasing trend and the tendency line was above the baseline. Conclusion: The results of this study suggest that the task-oriented training for left trunk flexion pattern using real-time ultrasound imaging has a beneficial effect on balance ability, the degree of unilateral neglect, and the strength of the lateral abdominal muscle in unilateral neglect patients.

Forward-Looking Ultrasound Imaging Transducer : II. Fabrication and Experimental Results

  • Lee, Chankil
    • The Journal of the Acoustical Society of Korea
    • /
    • 제15권2E호
    • /
    • pp.76-84
    • /
    • 1996
  • The experimental testing results of the large-scale version of a forward-looking ultrasound imaging catheter(FLUIC) are presented, along with the fabrication techniques used, experimental methods, and comparisons of the measured and simulated results. The transducer model is verified by measuring the electrical impedance of the transducer. The pulse width, beamwidth, and the dynamic range for both transmit and pulse-echo response of the fabricated FLUIC are also analyzed. The experimental results conformed its forward-looking imaging capability and the sources of discrepancies between the simulated and experimental beam profiles are addressed.

  • PDF

근근막 발통점의 활성도에 따른 초음파 영상구조 및 전기생리학적 특성 (Ultrasound Imaging and Electrophysiological Characteristic According to Activity Levels of Myofascial Trigger Point)

  • 김현진;김수현;박영현;오석;최지호;김태열
    • 대한임상전기생리학회지
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 2010
  • Purpose : This study is to offer clinical primary data that examines the change of imaging structure and the quantitative evaluation of muscle activity on myofascial trigger points. This study examines neuromuscular physiological characteristic by comparing the differences in physical findings, pressure pain threshold, imaging, and electrophysiological characteristics in latent and active myofascial trigger points muscle and normal muscle through the following experimental procedures. Methods : The participants for the study were thirty-three adults in their twenties. We divided three groups into normal, latent and active myofascial trigger points groups by physical findings. We analyzed the results of measured pressure pain, threshold for pain, ultrasound imaging perform for structure characteristic of muscle, surface EMG according to type of muscle contraction for function of muscle contraction. Results : Significant differences were indicated in pressure pain threshold (p<0.05). Significant differences were discovered in the ultrasound imaging analysis. There were increases in muscle Echogenicity white area index (p<0.001). There were significant differences that decrease in %MVIC (p<0.05), increase in MDF (p<0.05). Conclusion : From these results, active rnyotascial trigger points muscle showed quality deterioration on ultrasound imaging and decreased function of muscle contraction, increased motor unit action potential of II type fiber, and electrophysiologically. Imaging structure and neuromuscular physiological characteristic can be diagnostic and quantitative analytical techniques for myofascial pain syndrome and a primary factor that reflected in physical therapy intervention.

지간 신경종에서 보존적 치료 및 수술적 치료의 임상적 결과 (Clinical Result of Conservative Treatment and Operative Treatment for Interdigital Neuroma)

  • 이진우;한승환;서동석
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.31-36
    • /
    • 2006
  • Purpose: To evaluate the usefulness of ultrasound and MRI in diagnosing Morton's Neuroma, and the effect and significance of stepwise treatment. Materials and Methods: Out of all patients suspected of Morton's neuroma through history taking and physical examination, 77 patients (84 feet, 95 lesions) in whom Morton's neuroma was confirmed by ultrasound or MR imaging study or was clinically suspected with negative imaging studies, and followed up for over 3 months were included. In all cases, history taking and imaging study were done, and by comparison with operative findings of the patients, the sensitivity of ultrasound and MRI was checked. Postoperative evaluation was done using the AOFAS scale. The patient's satisfaction was also examined. Results: Morton's neuroma occurred most frequently at the $3^{rd}$ web space of the foot (56%), followed by the $2^{nd}$ web space (44%). Out of 15 cases suspected of morton's neuroma through ultrasound study, 13 were pathologically positive showing a sensitivity of 85.7%. Out of 16 cases suspected of morton's neuroma through MRI, 14 were pathologically positive showing a sensitivity of 83.3%. There was no significant difference in sensitivity between the two imaging modalities. Conclusion: In diagnosing Morton's neuroma, ultrasound examination had a similar sensitivity with MRI, therefore can be used as a screening study.

  • PDF

Ultrasonography Findings of the Carpal Tunnel after Endoscopic Carpal Tunnel Release for Carpal Tunnel Syndrome

  • Alex Wing Hung Ng;James Francis Griffith;Carita Tsoi;Raymond Chun Wing Fong;Michael Chu Kay Mak;Wing Lim Tse;Pak Cheong Ho
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1132-1141
    • /
    • 2021
  • Objective: To investigate changes in the median nerve, retinaculum, and carpal tunnel on ultrasound after successful endoscopic carpal tunnel release (ECTR). Materials and Methods: This prospective study involved 37 wrists in 35 patients (5 male, 30 female; mean age ± standard deviation [SD], 56.9 ± 6.7 years) with primary carpal tunnel syndrome (CTS). An in-house developed scoring system (0-3) was used to gauge the clinical improvement after ECTR. Ultrasound was performed before ECTR, and at 1, 3, and 12 months post-ECTR. Changes in the median nerve, flexor retinaculum, and carpal tunnel morphology on ultrasound after ECTR were analyzed. Ultrasound parameters for different clinical improvement groups were compared. Results: All patients improved clinically after ECTR. The average clinical improvement score ± SD at 12 months post-ECTR was 2.2 ± 0.7. The median nerve cross-sectional area proximal and distal to the tunnel decreased at all time intervals post-ECTR but remained swollen compared to normal values. Serial changes in the median nerve caliber and retinacular bowing after ECTR were more pronounced at the tunnel outlet than at the tunnel inlet. The flexor retinaculum had reformed in 25 (68%) of 37 wrists after 12 months. Conclusion: Postoperative changes in median nerve and retinaculum parameters were most pronounced at the tunnel outlet. Even in patients with clinical improvement after ECTR, nearly all ultrasound parameters remain abnormal at one year post-ECTR. These ultrasound parameters should not necessarily be relied upon to diagnose persistent CTS after ECTR.