• Title/Summary/Keyword: ultrasound imaging

Search Result 679, Processing Time 0.027 seconds

Photoacoustic Nonlinearity to Absorption Coefficients in Photoacoustic Imaging with Focused Ultrasound Transducers (초점 초음파 측정기로 측정한 광음향 신호의 광 흡수계수에 대한 비선형성)

  • Kang, Dongyel
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.158-165
    • /
    • 2017
  • The physical shape of an ultrasound transducer has not been considered in previous studies of the photoacoustic saturation effect, where a photoacoustic signal's magnitude linearly increases as an absorption coefficient increases and it is finally saturated. In this paper, the effect of a spherically focused ultrasound transducer on photoacoustic nonlinearity is investigated. The focused ultrasound transducer's spatial filtering effect on photoacoustic signals is analytically derived considering the combined concept of a virtual point detector and Green function approach. The ultrasound transducer's temporal response (i.e., transfer function) effect on photoacoustic signals is considered by integrating photoacoustic signal values within the absorption area covered by a spatial resolution of the ultrasound transducer. Results from the analytically derived expression show that the magnitude of photoacoustic signals measured by a spherical focused ultrasound transducer shows a maximum at a specific absorption coefficient, and decreases after that maximum point as an absorption coefficient is increased. The origin of this photoacoustic nonlinearity is physically understood by comparing the ultrasound transducer's transfer functions and photoacoustic resonance spectra. In addition, this physical interpretation implies that the photoacoustic nonlinearity is strongly dependent on the irradiance distribution inside an absorption medium.

A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging (초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출)

  • Cho, Jai-Wan;Chung, Chin-Man;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

Clinical Usefulness of Ultrasonography in Oral and Maxillofacial Regions (구강악안면영역에서 초음파영상 진단)

  • Oh, Song Hee;Choi, Yong-Suk
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.690-699
    • /
    • 2019
  • Ultrasound sonography(US) is used to evaluate various diseases of maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. Nevertheless, the clinical application of US imaging is limited in the dental field. This is due to the lack of knowledge about the US image and the image characteristics of the anatomical structures. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging.

  • PDF

Intramuscular Epidermal Cyst of the Buttock: A Case Report (대둔근 내에 발생한 피하낭종: 증례 보고)

  • Yim, Younghee;Kim, Na Ra;Moon, Sung Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.354-358
    • /
    • 2018
  • Epidermal cysts are common benign subcutaneous lesions that occur in or on the skin. It is not very difficult to diagnose subcutaneous epidermal cysts using ultrasound imaging because they exhibit typical sonographic features. However, the differential diagnosis can be confused when epidermal cysts are found in unusual sites. The authors report a case involving a 4-year-old girl who presented with an intramuscular epidermal cyst in the gluteus maximus muscle. Magnetic resonance imaging revealed characteristic internal features of the epidermal cyst, despite being in an uncommon site, and was very useful in the preoperative diagnosis.

Review of outcomes of using lower ethanol concentration (83%) in percutaneous ultrasound-guided renal cyst sclerotherapy in dogs

  • Sanghyeon Yoon;Jungmin Kwak;Deokho Im;Hakyoung Yoon
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.61.1-61.12
    • /
    • 2023
  • Background: Percutaneous renal cyst sclerotherapy (PRCS) as a treatment for renal cysts is usually performed with a high concentration of ethanol (≥ 90%). This study reviewed cases in which a lower concentration of ethanol (83%) was used for the procedure in dogs. Methods: Records of cases of renal cysts treated by sclerotherapy using 83% ethanol in dogs were reviewed. Outcomes of the treatment were evaluated by comparing volumes of renal cysts before the procedure and the volumes after treatment, using ultrasound images with the volume reduction rates classified as follows: < 50% of initial volume (failed); ≥ 50% but < 80% of initial volume (partial success); ≥ 80% but < 95% of initial volume (great success); ≥ 95% of initial volume (complete success). Results: Out of nine dog kidneys, renal cysts sclerotherapy with 83% ethanol achieved partial success in one kidney, great success in four, and complete success in the other four. No side effect was observed. The mean of the volume-reduction rates was 90.00 ± 11.00 while the minimum and maximum reduction rates were 65% and 100%, respectively. Conclusions: The lower ethanol concentration (83%) is good for disinfecting kidneys in PRCS.

Small Bowel Obstruction Induced by Fecal Material in a Dog

  • Daji Noh;Hyun-Guk Shin;Sang-Kwon Lee;Kija Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.4
    • /
    • pp.241-245
    • /
    • 2024
  • A 12-year-old spayed female dog presented with vomiting and anorexia for four days. Radiographic examination revealed that the small intestines were distended with fecal material. Ultrasound examination showed irregular marginated material with moderate shadowing throughout several segments of the small intestines. Proximal to this intestinal material, small intestines were distended with fluid. The patient underwent one-day of hospitalization, and descent of small bowel fecal materials (SBFMs) was confirmed on radiographs. However, surgical removal was performed due to worsening clinical signs and echogenic changes in the mesentery observed on ultrasound. During surgery, intestinal congestion was observed along with congestion and edema in the surrounding mesentery. Two segments of the small intestines were resected, and feces were found within the resected segments. The patient showed rapid recovery postoperatively and experienced no recurrence. SBFM can induce mechanical intestinal obstruction, and if radiographic evidence of SBFM is observed in patients with vomiting, surgical resection would be considered.

In Vivo Experimental Study on the Effects of Fluid in Increasing the Efficiency of Radiofrequency Ablation

  • Sun, Yi-Xin;Cheng, Wen;Han, Xue;Liu, Zhao;Wang, Qiu-Cheng;Shao, Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5799-5804
    • /
    • 2014
  • Background: Radiofrequency ablation (RFA) is the most widely used and studied method internationally for the local treatment of liver tumors. However, the extension of coagulation necrosis in one RFA procedure is limited and incomplete coverage of the damaged area can lead to a high local recurrence rate. Objective: In this study, we compared the effects of different solutions in enhancing hepatic radiofrequency by establishing a rabbit VX2 liver cancer model. We also determined the optimal solution to maximise effects on the extent of RFA-induced coagulation necrosis. Methods: Thirty VX2 tumor rabbits were randomly assigned to five groups: group A, RFA alone; group B, RFA with anhydrous ethanol injection; group C, RFA with 5% hypertonic saline injection; group D, RFA with lidocaine injection; and group E, RFA with a mixed solution. Routine ultrasound examinations and contrast-enhanced ultrasound (CEUS) of the ablation areas were performed after RFA. Then, we measured the major axis and transverse diameter and compared the areas of coagulation necrosis induced by RFA. Results: The mean ablation area range increased in groups B, C and especially E, and the scopes were greater compared with group A. Preoperative application of anhydrous ethanol, hypertonic saline, lidocaine and the mixed solution (groups B, C, D and E, respectively) resulted in larger coagulation necrosis areas than in group A (p<0.05). Among the groups, the coagulation necrosis areas in group E was largest, and the difference was statistically significant compared with other groups (p<0.05). Pathological findings were consistent with imaging results. Conclusions: A mixture of dehydrated alcohol, hypertonic saline and lidocaine injected with RFA increases the extent of coagulation necrosis in the liver with a single application, and the mixed solution is more effective than any other injection alone.