• Title/Summary/Keyword: ultrasound energy

Search Result 188, Processing Time 0.024 seconds

Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman (골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계)

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.542-547
    • /
    • 2009
  • In this in vivo study, correlations of lumbar and femoral bone mineral densities (BMDs) with calcaneal speed of sound (SOS) were investigated in 36 osteoporotic women. Areal BMDs of the L2-L4 lumbar spine and the right femoral neck were measured by using dual energy X-ray absorptiometry (DEXA). SOS of the right calcaneus was measured by using ultrasound bone densitometry. Pearson's correlation coefficient (r) and level of significance (p) were used to evaluate the correlations between measurements. Lumbar BMD was highly correlated with femoral BMD (r=0.81). Lumbar and femoral BMDs exhibited similar comparable negative correlations with age (r=-0.52 and r=-0.55). A moderate negative correlation was found between calcaneal SOS and age (r=-0.45). Calcaneal SOS was significantly correlated with lumbar and femoral BMDs, with a higher correlation with femoral BMD rather than with lumbar BMD (r=0.54 and r=0.62). However, calcaneal SOS may not be an optimum index for the estimation of BMD of the most important fracture sites, such as the lumbar and the femur, because it showed lower correlations with lumbar and femoral BMDs compared to that with calcaneal BMD. Therefore, the development of a quantitative ultrasound technology for the direct measurement of acoustic properties at the lumbar and the femur is required to estimate BMD of these sites more accurately.

A study on the fabrication of lithium carbonation powder by gas-liquid reaction using ultrasonic energy (탄산리튬 분말 제조에 있어서 초음파 에너지를 적용한 기액반응에 관한 연구)

  • Kim, Dae-Weon;Kim, Bo-Ram;Choi, Hee-Lack
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2020
  • In the previous study, we reported the result to prepare lithium carbonate powder from various lithium-contained solution. Therefore, using the lithium hydroxide solution, it is conformed that the reaction could occur thermodynamically, and the recovery rate of lithium was 89.4 %. In this study, we carried out the experiment to prepare lithium carbonate powder through gas-liquid reactions with lithium hydroxide solution and CO2 gas using ultrasound energy. In case ultrasonic energy is applied to the reaction of lithium carbonate, the recovery rate of lithium at room temperature was approximately 83.8 %, and the recovery rate of lithium was greatly increased to approximately 99.9 % at 60℃ reaction temperature. And when ultrasonic energy is not applied, the particle size of lithium carbonate powder was 7.7 ㎛ in D50. But the particle size of lithium carbonate powder was significantly reduced to 8.4 ㎛ in D50 under the influence of ultrasonic.

Detection of Cracks in feeder Pipes of Pressurized Heavy Water Reactor Using an EMAT Torsional Guided Wave (EMAT의 유도초음파 비틀림 모드를 이용한 가압중수로 피더관의 균열 검출)

  • Cheong, Yong-Moo;Kim, Sang-Soo;Lee, Dong-Hoon;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2004
  • A torsional guided wave mode was applied to detect a crack in a pipe. An array of electromagnetic acoustic transduce. (EMAT that can generate and receive torsional guided ultrasound with the frequency of 200kHz was designed and fabricated for testing a pipe of 2.5 inch diameter Artificial notches with various depths were fabricated in a bent feeder pipe mock-up and the detectability was examined from the distance of 2m of the specimen. The axial notches with the depth of 5% of wall thickness were successfully detected by a torsional mode (T(0,1)) generated by the EMAT However, it was found that the depth of defects was not related to the signal amplitude.

Measurement of the Quantity of Hydrogen Peroxide Produced in the Ultrasound-irradiated Aqueous Solution of Organic Compounds (초음파를 조사(照射)한 유기화합물 수용액 속에서의 과산화수소 생성량의 측정)

  • Mo, Se-Young;Chang, Hong-Ki;Lee, Kyung-Jae;Jang, Gun-Eik;Sohn, Jong-Ryeul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 2000
  • When irradiate the power ultrasound into the aqueous solutions, water vapor is decomposed by the heat of very high temperature in the cavitation bubble to produce OH (hydroxyl radical) and H (hydrogen radical), and these radicals play a role in decomposing the substances in aqueous solution by oxidation and/or reduction, and in producing the hydrogen peroxide. Accordingly it is possible to predict that the quantity of hydrogen peroxide produced may correlate with the sonolysis mechanism of the substance in aqueous solution. Thus to confirm this prediction, the quantities of hydrogen peroxide produced from each of the air saturated distilled water and three aqueous solutions of TCE, benzene, and 2,4-DCP that are prepared by dissolving them into distilled water are measured. As a result, it showed that the quantity of hydrogen peroxide produced from the distilled water and three aqueous solutions are increased in order of distilled water>TCE solution>2,4-DCP solution>benzene solution, and decrease with decrease in concentration of organic substance, which coincide with the sonolysis mechanisms reported that TCE in aqueous solution is decomposed directly by the pyrolysis in and around the cavitation bubbles when its concentration is high and by the radical reaction when low, however, benzene and 2,4-DCP are decomposed not only by the pyrolysis but also by the radical reactions. Effects of such experimental parameters as the acoustic frequency and power and as the concentration showed that the higher the acoustic frequency and the lower the acoustic power, the less the quantity of hydrogen peroxide was produced. This result coincide with the theory of ultrasound for the relation between the cavitation that is the energy source of the power ultrasound in aqueous solution and these experimental parameters.

  • PDF

Twelve-Month Volume Reduction Ratio Predicts Regrowth and Time to Regrowth in Thyroid Nodules Submitted to Laser Ablation: A 5-Year Follow-Up Retrospective Study

  • Roberto Negro;Gabriele Greco;Maurilio Deandrea;Matteo Rucco;Pierpaolo Trimboli
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.764-772
    • /
    • 2020
  • Objective: Laser ablation is a therapeutic modality used to reduce the volume of large benign thyroid nodules. Unsatisfactory reduction and regrowth are observed in some treated nodules. The aim of the study was to evaluate the long-term outcomes of laser treatment for solid nodules during a 5-year follow-up period, the regrowth rate, and the predictive risk factors of nodule regrowth. Materials and Methods: We retrospectively evaluated patients with benign, solid, cold thyroid nodules who underwent laser ablation and were followed-up for 5 years. According to the selection criteria, 104 patients were included (median baseline nodule volume, 12.5 mL [25.0-75.0%, 8-18 mL]; median energy delivered, 481.5 J/mL [25.0-75.0%, 370-620 J/mL]). Nodule volume, thyroid function test results, and ultrasound were evaluated at baseline and then annually after the procedure. Results: Of 104 patients, 31 patients (29.8%) had a 12-month volume reduction ratio (VRR) < 50.0% and 39 (37.5%) experienced nodule regrowth. Of these 39 patients, 17 (43.6%) underwent surgery and 14 (35.9%) underwent a second laser treatment. The rate of nodule regrowth was inversely related to the 12-month VRR, i.e., the lower the 12-month VRR, the higher the risk of regrowth (p < 0.001). The mean time for nodule regrowth was 33.5 ± 16.6 months. The 12-month VRR was directly related to time to regrowth, i.e., the lower the 12-month VRR, the shorter the time to regrowth (p < 0.001; R2 = 0.3516). Non-spongiform composition increased the risk of regrowth with an odds ratio of 4.3 (95% confidence interval [CI] 1.8-10.2; p < 0.001); 12-month VRR < 50.0% increased the risk of regrowth with an odds ratio of 11.7 (95% CI 4.2-32.2; p < 0.001). Conclusion: The VRR of thyroid nodules subjected to similar amounts of laser energy varies widely and depends on the nodule composition; non-spongiform nodules are reduced to a lesser extent and regrow more frequently than spongiform nodules. A 12-month VRR < 50.0% is a predictive risk factor for regrowth and correlates with the time to regrowth.

Electrochemical Behavior of Li4Ti5O12/CNT Composite for Energy Storage

  • Kim, Hong-Il;Yang, Jeong-Jin;Kim, Han-Joo;Osaka, Tetsuya;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.4
    • /
    • pp.235-239
    • /
    • 2010
  • The $Li_4Ti_5O_{12}$/CNT composite is prepared by ultrasound associated sol-gel method. The prepared composite is characterized by SEM, TEM, XRD and TG analysis, and their electrochemical behaviors are investigated by cyclic voltammetry, electrochemical impedance spectroscopy and charge-discharge test in 1M $LiBF_4$/PC electrolyte. From the results, it is identified that the $Li_4Ti_5O_{12}$ nanoparticles coated on CNT surface have regular size with around 10~30 nm and spinel-framework structure. At the current rate of 20C, the discharge capacities of $Li_4Ti_5O_{12}$/CNT composites with CNT contents of 15, 30 and 50 wt% are 57, 63 and $48mAhg^{-1}$, respectively, which have similar value. The improved electrochemical behavior of the $Li_4Ti_5O_{12}$/CNT composite electrode is attributed to the addition of CNT with electronic conductivity.

UT Inspection Technique of Cast Stainless Steel Piping Welds Using Low Frequency TRL UT Probe (저주파수 TRL 탐촉자를 이용한 Cast Stainless Steel 배관 용접부 초음파탐상기법)

  • Shin, Keon-Cheol;Chang, Hee-Jun;Jeong, Young-Cheol;Noh, Ik-Jun;Lee, Dong-Jin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.29-36
    • /
    • 2010
  • Ultrasonic inspection of heavy walled cast austenitic stainless steel(CASS)welds is very difficult due to complex and coarse grained structure of CASS material. The large size of anisotropic grain strongly affects the propagation of ultrasound by severe attenuation, change in velocity, and scattering of ultrasonic energy. therefore, the signal patterns originated from flaws can be difficult to distinguish from scattered signals. To improve detection and sizing capability of ID connected defect for heavy walled CASS piping welds, the low frequency segmented TRL Pulse Echo and Phased Array probe has been developed. The experimental studies have been performed using CASS pipe mock-up block containing artificial reflectors(ID connected EDM notch). The automatic pulse echo and phase array technique is applied the detection and the length sizing of the ID connected artificial reflectors and the results for detection and sizing has been compared respectively. The goal of this study is to assess a newly developed ultrasonic probe to improve the detection ability and the sizing of the crack in coarse-grained CASS components.

  • PDF

Sonochemical and Sonophysical Effects in a Downward-Irradiation Sonoreactor (하향 초음파 조사 시스템에서의 초음파 화학적 및 물리적 효과 평가)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.3
    • /
    • pp.23-31
    • /
    • 2020
  • The performance of a downward-irradiation sonoreactor was investigated using calorimetry, KI dosimetry, luminol (Sonochemiluminescence, SCL) method, and aluminium foil erosion method as one of the basic steps for the optimal design of downward-irradiation sonoreactors. The applied frequency was 28 kHz and the input electrical power was 280 - 300 W. The liquid height, from the reactor bottom to the transducer module surface, ranged from 1λ (53.6 mm) to 2λ (107.1 mm). For various liquid heights, the magnitude of calorimetric power and the mass of cavitation-generated I3- ion varied significantly. It was found that the additional application of mechanical mixing resulted in higher sonochemical activity, especially in the cavitational active zone, which was induced by violent liquid flow in the reactor. In aluminium foil erosion tests, it was found that less ultrasound energy reached the bottom of the reactor due to the violent liquid flow and no significant sonophysical effect was observed for higher mixing rate conditions (100 and 200 rpm).

A Method and Effect for Tibial Defect Treatment Using Interstitial Low Level Laser (경골 손상 치료에서의 침습형 저출력 레이저 치료법 및 효과)

  • Lee, Sangyeob;Hwang, Donghyun;Kim, Hansung;Jung, Byungjo
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.147-151
    • /
    • 2016
  • Tibial defect, or fracture is very routine musculoskeletal case which brings fully uncomfortable and painful situations to patient. Moreover, it has long hospitalization period because of its risk of non-union. There are many studies using ultrasound, vibration, and laser for bone regeneration to figure out fast bone healing. Among them, Low Level Laser Therapy (LLLT) is already known that it is very easy to treat and may have positive effect for bone regeneration. However, LLLT has uncertain energy dose because of scattering and absorption of laser in tissue. In this study, we used interstitial LLLT to treat tibial defect in animal study. The Interstitial LLLT can overcome some limitations caused by laser scattering or absorption in tissue medium. The results were evaluated using u-CT which can calculate X-ray attenuation coefficient and bone volume of bone defect area. These results showed that interstitial LLLT may affect fast bone healing process in early phase.

Effects of pH, molar ratios and pre-treatment on phosphorus recovery through struvite crystallization from effluent of anaerobically digested swine wastewater

  • Kim, Daegi;Min, Kyung Jin;Lee, Kwanyong;Yu, Min Sung;Park, Ki Young
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.12-18
    • /
    • 2017
  • Struvite precipitation has been proven to be an effective method in removing and recovering ammonia nitrogen (N) and phosphate phosphorus (P) from wastewater. In this study, effects of pH, molar ratios and pre-treatment of effluent of anaerobically digested swine wastewater were investigated to improve struvite crystallization. The magnesium : ammonium : phosphate ratio of 1.2 : 1.0 : 1.0 was found to be optimal, yet the molar ratio in the wastewater was 1 : 74.9 : 1.8. From the analysis, the optimum pH was between 8.0 and 9.0 for maximal phosphate P release and from 8.0 to 10.0 for maximal ammonia N and phosphate P removal from real wastewater. Analysis from Visual MINTEQ predicted the pH range of 7-11 for ammonia N and phosphate P removal and recovery as struvite. For pre-treatment, microwave pre-treatment was ineffective for phosphate P release but ultrasound pre-treatment showed up to 77.4% phosphate P release at 1,000 kJ/L of energy dose. Precipitates analysis showed that phosphorus and magnesium in the collected precipitate had almost same values as theoretical values, but the ammonia content was less than the theoretical value.