Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study - (복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study-)

  • Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

Development of Master-slave System for Robot-assisted Remote Ultrasound Diagnosis (로봇 지원 원격 초음파 영상진단을 위한 마스터-슬레이브 시스템의 개발)

  • Seo, Joonho;Cho, Jang Ho;Kwon, Ohwon
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.4
    • /
    • pp.395-401
    • /
    • 2017
  • In this paper, we introduce a robot-assisted medical diagnostic system that enables remote ultrasound (US) imaging to be applied to the conventional telemedicine, which has been possible only with interviewing or a visual exam. In particular, a master-slave robot system is developed that ultrasonic diagnosis specialist can control the position and orientation of US probe in the remote place. The slave robot is designed to be compact, lightweight, and hand-held so that it can easily transfer to the remote healthcare center. Moreover, 6-degree-of-freedom (DOF) probe motion is possible by the robot design based on Stewart platform. The master device is also based on a similar structure of the slave robot. To connect master and slave system in the wide area network (WAN) environment, a hardware CODEC was developed. In this paper, we introduce the detail of each component and the results of the recent experiments conducted in the remote sites by the developed robotic ultrasound imaging system.

A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care (미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구)

  • Lee, Woo-Cheol;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1259-1264
    • /
    • 2016
  • Ultrasonic therapy has received great attention in the field of cosmetics related to the treatment of skin thickening because of its fast recovery and safety. In this study, an output circuit of a high intensity focused ultrasound system was developed for the treatment of beauty. To verify the applicability of the high intensity focused ultrasound system to the cosmetic treatment field, we measured and analyzed the 3D ultrasound intensity energy using a hydrophone. And high-intensity focused ultrasound devices were found to be useful for cosmetic treatment.

An Benefit-cost Analysis of the Cleaning Device for Photovoltaic Power Generation Systems in Buildings (건축물에 설치된 태양광발전설비를 위한 세척장치의 편익-비용 분석)

  • Kim, Jae-Yeob;Won, Jongsung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.587-594
    • /
    • 2016
  • This study aims to analyze the benefit-cost of the cleaning device for photovoltaic power generation systems in buildings in order to check its economic feasibility. A product, which has similar characteristics to the ultrasound-based cleaning device and is widely used in South Korea, was selected to compare with the benefit-cost value of the ultrasound-based cleaning device in this study. In order to quantitatively and qualitatively analyze benefit and cost aspects of the two products, categories and evaluation factors of each aspect as well as evaluation criteria were identified. Based on the identified evaluation factors and criteria, this study conducted face-to-face interviews with 15 experts to measure weights of benefit and cost aspects of the products. As the results, the total benefit weight of the ultrasound-based cleaning device was larger than its total cost weight since the benefit-cost value was greater than 1, which was 1.6 times of that of to compared product. Therefore, from the economic perspective, it is worth to develop the cleaning device for photovoltaic power generation systems applying ultrasound technology.

The Effects of Functional Electrical Stimulation on Abdominal Obesity Improvement of Adult Women by EMG, Ultrasound and DITI (근전도, 초음파와 DITI를 이용한 전기자극의 성인여성 복부비만 개선 효과 관찰)

  • Lee, Hyun-Ju;Tae, Ki-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.1051-1058
    • /
    • 2014
  • In this study, we investigated the improvement effect of obesity by treatment with a developed low frequency electrical stimulation system. Thirty female in their 20's as an experiment subjects divided 3 groups(control, commercialized device, developed device) were treated with electrical stimulation on abdomen for 4 weeks. The body weight, body mass index(BMI), waist-hip ratio(WHR), muscle strength, muscle(transverse abdominis(TrA), internal obliquus abdominis(IO), external obliquus abdominis(EO)), fat thickness and abdominal surface temperature were measured by electromyogram(EMG), ultrasound and digital infrared thermal image(DITI). In the result, the body weight and BMI were decreased. Subcutaneous abdominal fat were significantly reduced after 4 weeks. The muscle strength and TrA muscle thickness was increased 13.2%(p<0.05), and 35.5%, respectively. The fat thickness showed decrease in abdomen (p<0.05). Infrared measurement on abdominal surface temperature as a parameter of improvement in blood circulation was significantly increased(p<0.05). Therefore, the low frequency stimulation showed positive effects on parameters of the obesity improvement.

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

Piezoelectric Ultrasound MEMS Transducers for Fingerprint Recognition

  • Jung, Soo Young;Park, Jin Soo;Kim, Min-Seok;Jang, Ho Won;Lee, Byung Chul;Baek, Seung-Hyub
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.286-292
    • /
    • 2022
  • As mobile electronics become smarter, higher-level security systems are necessary to protect private information and property from hackers. For this, biometric authentication systems have been widely studied, where the recognition of unique biological traits of an individual, such as the face, iris, fingerprint, and voice, is required to operate the device. Among them, ultrasound fingerprint imaging technology using piezoelectric materials is one of the most promising approaches adopted by Samsung Galaxy smartphones. In this review, we summarize the recent progress on piezoelectric ultrasound micro-electro-mechanical systems (MEMS) transducers with various piezoelectric materials and provide insights to achieve the highest-level biometric authentication system for mobile electronics.

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow (혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Young-Kil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.