• 제목/요약/키워드: ultrasonographic measurement

검색결과 46건 처리시간 0.023초

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

Ultrasonographic Assessment of the Cutaneous Changes Induced by Topical Use of Novel Peptides Comprising Laminin 5

  • Park, Kyong Chan;Kim, Se Young;Khan, Galina;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.304-309
    • /
    • 2022
  • Background Laminin 5, which is found in the basement membrane of dermal-epidermal junction (DEJ), is a major adhesive component and associated with proliferating and migrating keratinocytes. In this study, we hypothesized that the topical application of the skin care products containing the novel peptides might restore the DEJ structure by deriving deposition of laminin 5 and promoting the keratinocyte migration. Here, we evaluated the restoration of DEJ by measuring the skin thickness. Methods Single-center retrospective analysis was performed on a total of 13 patients who underwent skin care using Baume L.C.E. (France, Laboratories d' Anjou) between January and March 2021. All patients applied the skin care agent for 2 weeks only on their left hand dorsum. Before the initiation of the application and after 2 weeks, both their hands were evaluated on photography and ultrasound. And the patients were asked to rate their satisfaction with the questionnaire after 2 weeks. Results There was no obvious improvement in photographic assessment and questionnaire. The post-pre difference of skin thickness in ultrasound images was, in left hand, 0.1 ± 0.37 in distal point and 0.1 ± 0.35 in proximal point; and, in right hand, 0 ± 0.17 in distal point and 0 ± 0.15 in proximal point, respectively. The pre-post difference was statistically significant in proximal point (p = 0.035). Conclusion Topical application of novel peptide derivative comprising laminin 5 demonstrated cutaneous changes including skin thickness, as assessed by ultrasound. Further studies using other modalities including dermal density measurement, three-dimensional photography, optical coherence tomography, or skin biopsy would be helpful to determine the skin-improving effects.

Correlating two-dimensional shear wave elastography of acute pancreatitis with Spec cPL in dogs

  • Cho, Hyun;Yang, Seungwhwa;Suh, Gukhyun;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • 제23권5호
    • /
    • pp.79.1-79.11
    • /
    • 2022
  • Background: Pancreatitis is a common disease in which 37% of dogs had evidence of acute or chronic pancreatitis at necropsy. Although biopsy is still the gold standard to diagnose acute pancreatitis, clinical data including ultrasonographic findings and measurement of canine serum pancreatic lipase immunoreactivity (cPLI) are used in routine. However, it may be insufficient in the diagnostic approach to acute pancreatitis. Objectives: To evaluate the clinical diagnostic feasibility of two-dimensional shear wave elastography (2D SWE) on canine acute pancreatitis for enhanced diagnostic confidence. Methods: 2D SWE was used to assess pancreatic stiffness and determine the correlation between pancreatic shear wave velocity (SWV) and Spec cPL concentration in 31 dogs with healthy pancreas and 10 dogs with acute pancreatitis. Results: The pancreatic SWV was significantly higher in the acute pancreatitis group (2.67 ± 0.20 m/s) than in the healthy pancreas group (2.30 ± 0.26 m/s; p < 0.05). The moderate positive correlation was found between the pancreatic SWV and Spec cPL concentration (95% confidence interval, 0.214-0.693; r = 0.489; p < 0.05). Conclusions: These results indicated that 2D SWE was feasible for assessing pancreatic stiffness in acute pancreatitis, and that pancreatic SWV using 2D SWE correlated with Spec cPL concentration. SWE could provide a quantitative measure of pancreatic stiffness, which can increase the accuracy of diagnosing acute pancreatitis in dogs. The 2D SWE can be used as a complementary imaging modality for diagnosing acute pancreatitis in dogs.

슬관절 골관절염에서 초음파를 이용한 대퇴 내과 관절 연골의 두께 측정 (Ultrasonographic Measurement of Articular Cartilage Thickness of Medial Femoral Condyle in Knee Osteoarthritis)

  • 김정만;김태형;임동선;강민구;이규조
    • 대한정형외과 초음파학회지
    • /
    • 제4권1호
    • /
    • pp.7-14
    • /
    • 2011
  • 목적: 체중 부하 엑스선 상의 관절 간격과 초음파 검사상의 대퇴 연골 두께를 비교, 상관 관계를 조사하여 초음파 검사의 유용성을 확인하고자 하였다. 대상 및 방법: 2010년 6월에서 2010년 9월까지 체중 부하 엑스선 검사와 함께 초음파 검사로 관절 연골의 두께를 측정한 73명을 대상으로 하였다. 우측 35예, 좌측 20예, 양측 18예로 전체 91예였다. 엑스선 상 내측 관절 간격은 완전 신전 전후면 상과 $45^{\circ}$도 후전면 상(Rosenberg view)에서 각각 측정하였다. 초음파 검사는 앙와위에서 $30^{\circ}$ 굴곡 및 $130^{\circ}$ 굴곡 상태에서 관상 스캔을 실시하여 전방 1/3과 중간 1/3 사이 지점 및 중간 1/3과 후방 1/3 사이의 체중 부하부위에 해당되는 지점의 내측 대퇴 연골의 두께를 측정하였다. 엑스선 검사와 초음파 검사상의 각각의 측정값을 Pearson correlation test과 Bland-Altman plot 통계학적 검정으로 비교 분석하였다. 결과: 완전 신전 전후면 상에서 관찰된 전방부의 관절 간격과 초음파 상 30도 굴곡 위치에서 측정한 전방 1/3과 중간 1/3 사이 지점의 관절 연골 두께 측정치는 통계적으로 유의한 상관 관계를 가졌고, 엑스선 상 $45^{\circ}$도 후전면 상에서 관찰된 후방부 관절 간격과 초음파 검사 상 $130^{\circ}$ 굴곡 위치에서 측정한 중간 1/3과 후방 1/3 사이 지점의 관절 연골 두께 측정치 사이에서도 유의한 상관 관계를 나타내었다(P<0.05, $SD{\pm}2$). 결론: 기립이나 체중 부하를 할 수 없는 골관절염 환자에서도 초음파 검사는 외래에서 손쉽게 슬관절 대퇴 관절 연골의 두께를 측정하고 연골 손상의 정도를 평가할 수 있어 진단 및 경과 관찰의 도구로서 유용하다고 생각된다.

  • PDF

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

과배란유도 여성에서 우성난포의 성장속도 (Growth Rate of Dominant Follicles During Controlled Ovarian Hyperstimulation)

  • 황은주;구승엽;김용진;지병철;서창석;김석현;최영민;김정구;문신용
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제37권3호
    • /
    • pp.253-259
    • /
    • 2010
  • 목 적: 과배란유도 환자에서의 우성난포의 성장속도와 임상인자들과의 연관성을 평가하고자 하였다. 연구방법: 체외수정시술을 위한 과배란유도 313주기를 대상으로 혈중 호르몬 농도를 측정하고 과배란유도 주기 중 난포 직경의 변화를 초음파를 이용하여 연속적으로 측정하였다. 우성난포의 성장 속도를 계산하고, 임상지표와의 연관성을 분석하였다. 결 과: Gonadotropin releasing hormone 작용제와 길항제 주기 사이에 우성난포의 성장속도의 유의한 차이는 관찰되지 아니하였다. 우성난포의 성장속도와 환자의 연령, 체질량 지수, 생리 시작 3일의 follicle stimulating hormone, luteinizing hormone, 에스트라디올, 획득 난자의 수, 수정률 등의 임상지표는 유의한 연관성이 없었다. 결 론: 본 연구 결과는 우성난포의 성장속도는 난소 반응을 포함한 임상지표와 연관성이 없는 독립적인 변수임을 시사한다.