• Title/Summary/Keyword: ultrasonographic measurement

Search Result 46, Processing Time 0.023 seconds

Influence of Breathing Patterns on the Thickness of Sternocleidomastoid Muscle and Deep Cervical Flexor Muscles During Craniocervical Flexion Exercise (호흡패턴이 머리목 굽힘 운동시 목빗근과 심부 목굽힘근의 근두께에 미치는 영향)

  • Won, Jong-im
    • Physical Therapy Korea
    • /
    • v.25 no.2
    • /
    • pp.44-52
    • /
    • 2018
  • Background: The deep cervical flexor (DCF) muscles have a crucial role in the management of neck pain. For preventing neck pain by activation of the DCF, craniocervical flexion (CCF) is an effective exercise. However, sternocleidomastoid (SCM) muscle is considered to affect negatively the activation of the DCF. SCM muscle which is an accessory muscle for respiration is activated differently depending on types of breathing patterns. It's not certain that breathing patterns affect the SCM and DCF muscles thickness during CCF exercise. Objects: The purpose of this study was to investigate the influence of breathing patterns on the SCM and DCF muscles thickness during CCF exercise. Methods: Forty-five subjects participated in this study, and they were classified according to their breathing pattern, as follows: costodiaphragmatic breathing (CDB) and upper costal breathing (UCB) groups. Ultrasonographic imaging of the SCM and DCF muscles was performed during five incremental levels of CCF during tidal breathing and expiration. Results: There was a significant interaction between the breathing pattern and the phase of CCF for percentage of SCM muscle thickness changes (p<.05). In phase 1 CCF, a percentage of SCM muscle thickness changes was increased in the UCB group than in the CDB group (p<.05). There was an increase in DCF muscles thickness with each additional CCF phase (p<.05). Conclusion: Recruitment of SCM muscle was increased in the UCB group while performing CCF with a low intensity. There were no significant differences on DCF recruitment between the breathing pattern groups. Higher CCF exercise intensities elicited a higher DCF recruitment.

Ultrasonographic Appearance of the Gestational Structures Throughout Pregnancy in Shih-tzu bitches II. Estimation of Gestational Age by Measurement of the Fetal and Extra-fetal Structures (Shih-tzu견에서 임신일령에 따른 임신구조물의 초음파상 II. 태아 및 태아외구조물의 측정에 의한 임신일령의 추정)

  • 김방실;고진성;황순신;이순애;조양택;오기석;김성호;박인철;김종택
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.143-148
    • /
    • 2004
  • Serial ultrasonographic examination was daily performed on 12 pregnant Shih-tzu bitches from day 15 until parturition to determine the size of gestational structures. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0 ng/ml. Extra-fetal structures were measurable from days 17 to 46. Outer uterine diameter increased from $9.9{\pm}0.4$ mm (Mean${\pm}$SD) at day 20 to $44.3{\pm}0.8$ mm at day 46 and inner chorionic cavity diameter increased from $7.2{\pm}0.2$ mm at day 17 to $36.9{\pm}1.5$mm at day 41. Length of chorionic cavity or zonary placenta increased from $6.6{\pm}0.4$ mm at day 21 to $46.4{\pm}0.9$ mm at day 44. Of the extra-fetal structures, inner chorionic cavity diameter was the most accurate for estimation of gestational age until day 38. Fetal structures were measurable from days 23 to 60. Crown-rump length increased from $3.9{\pm}0.3$ mm at day 23 to $55.2{\pm}3.3$ mm at day 41, fetal body diameter increased from $7.9{\pm}0.6$ mm at day 32 to $47.8{\pm}2$ mm at day 60, and fetal head diameter increased from $6.3{\pm}1.1$ mm at day 29 to $25.6{\pm}0.2$ mm at day 60. Of the fetal structures, fetal head diameter was the most accurate for estimation of gestational age from day 38 until day 60.

Establishment of a prediction table of parturition day in Shih-tzu bitches with ultrasound scanning (Shih-tzu견에서 초음파 검사에 의한 분만일 예시표 확립)

  • Kim, Bang-sil;Ko, Jin-sung;Lee, Sun-ae;Cho, Yang-tak;Kim, Jae-pung;Oh, Ki-seok;Kim, Jong-taek;Park, In-chul;Kim, Young-hong;Son, Chang-ho
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.303-310
    • /
    • 2004
  • To establish a prediction table of parturition day real-time B-mode ultrasonographic examinations were performed in 12 pregnant Shih-tzu bitches. Measurement of inner chorionic cavity diameter and fetal head diameter was performed from 15 days of gestation to parturition. These were converted retrospectively based on the day of parturition (Day 0). The data of inner chorionic cavity diameter obtained from Day -44 to Day -25 and fetal head diameter obtained from Day -25 to Day -1 were used to compile a prediction table of parturition day. The 22 pregnant Shih-tzu with unknown mating time were examined to assess an accuracy of the table established in this study. And these results were applied to the prediction of parturition day and compared to actual parturition day. Parturition day prediction based on the inner chorionic cavity diameter and fetal head diameter was 100% accurate within ${\pm}2$ days. In addition, the accuracy for parturition day within 0, ${\pm}1$, and ${\pm}2$ days interval using the prediction table of parturition day were 68, 82, and 100%, respectively. Therefore, the prediction table of parturition day seems to be a useful tool for the prediction of parturition day in practice.

Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows II. Differential Diagnosis of Subestrous Dairy Cows (초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 II. 무발정우의 감별진단)

  • 강병규;최한선;강현구;오기석;서동호;손창호;서국현
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.307-318
    • /
    • 1998
  • Accuracy of rectal palpation and ultrasonography for differential diagnosis of subestrous dairy trows were investigatedl using the result of pIRsma progesterone assay. The ovaries were examined 2 times of 10 days interval in 520 posearom and postinsemination subestroHs dairy cows, using rectal palpation and B-mode transrectal ultrasonography. The results of rectal palpation, ultrasonographic examination and measurement of plasma progesterone profiles in 520 subestrous dairy cows were silent brat or error of estrus detection 303 (58.3%), persistent corpus luteum 59 (11.3%), follicular cyst 37 (7.1%), luteal cyst 16 (3.1%), inactive ovary 9 (1.7%), granulosa tumor 1 (0.2%), hydmsalphinx 1 (0.2%), endomehris 81 (15.6%), pyometra 12 (2.3%) and mummified fetus 1 (0.2%), respectively. Accuncy of rectal palpation and ultrasonography for diagiosing ovarian disordeir based on plasma progesterone profiles were silent heat or error of estrus detection 80.5% and 96.7%$\boxUl$ persistent corpus luteum 57.6% and 94.9%, follicular cyst 62.5% and 91.9%1 luteal cyst 62.5% and 87.5%, maclive ovary 55.6% and 88.9% and granulosa cell tumor 100% and 100%, respectively. Acnuucy of rectal palpation for diagnosing uterine disorders based on ultrasonography was pyometra 75.0%1 endometritis 51.9% and mummified fetus 100%, respectively. Cbaracteristic ultrasonographic appearances of ovaries in subestrous dairy cows were as follows; Silent heat or error of estrus detection: anechoic follicle or hypoechoic corpus luteum than ovarian stroma was alternately present on Day 0 (first examination) and Day 10. Follicular cyst: uniformly nonechogenic ovarian structure $\geq $ 25 mm in diameter with a wall < 3 mm was present in ipsilateral on Day 0 and Day 10. Luteal cyst: luteal cyst was similar to follicular cysts but thickness of cystic wall was $\geq $ 3 mm. Inactive ovary : structures within ovaries was not present on Day 0 Bnd Day 10. Characteristic uthssonograpsc appearances of uterus in subestrous dairy cows were as follows; Endometritis: characterized by uterine lumen containing fluid in which 'snowy'echogenic particles art suspended. Pyometra: ultrasonographic appearance of pyometra was diffuse echogenic particles distributed in fluid within the distended uterus, and a thickened uterine wall. These results indicated that ultrasonography was practical far diagnosing reproductive disorders. To diagnosing ovarian disorders, ultrasonography should be carried out 2 times of 10 days interval and rndometritis should be differentiated with uterus of luteal phase in normal cycling cows.

  • PDF

Reliability of Thickness Measurements of the Abductor Hallucis Muscle Using the Spring Gauge Technique in Hallux Valgus Subjects: An Ultrasonographic Study

  • Jeon, In-cheol;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.119-123
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurements of the abductor hallucis (AbdH) in subjects with hallux valgus (HV), using ultrasonography performed at different inward pressures of approximately 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg, with no pressure control. Methods: Thirty-two subjects with HV were recruited. The thicknesses of both sides of the AbdH were measured randomly by two different examiners for assessment of the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability of MT measurements of the AbdH, while ICC (3,1) was used to assess the intra-rater reliability. Results: The results showed higher ICC values for intra-rater reliability compared to inter-rater reliability, and the value for inter-rater reliability with no pressure control (ICC=0.74 [95%CI=0.53-0.87]) was smaller compared to pressures of 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability also showed excellent values (ICC=0.86-0.96). Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results in measurement of the MT of the AbdH by different examiners in a clinical setting.

The suggestion of Proper Pressure level in Cranio-Cervical Flexion Exercise for Deep Cervical Flexor by Ultrasonographic Measurement (초음파 영상을 통한 머리-목 굽힘 운동의 적정 수준 제시에 관한 연구)

  • Jun, Deok-Hoon;Fell, Dennis W.;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.497-504
    • /
    • 2011
  • Purpose : Chronic cervical pain is a common source of disability in society. There has been no research regarding the amount of pressure for the deep cervical flexors during cranio-cervical flexion exercise (CCFE). The purpose of this study is to determine optimal pressure levels to facilitate deep cervical muscles (longus colli & longus capitis) during cranio-cervical flexion exercise, using ultrasound measurement of the muscles. Methods : Using a cross-sectional design, the study was performed in an experimental group of 19 subjects (7 men, 12 women) with no cervical pain. Participants were instructed to perform the CCFE, and during the five incremental stages of the test, changes in thickness, as compared to resting baseline values, were measured using ultrasonography for sternocleidomastoid muscle (SCM) and deep cervical muscles (DCF). Results : Both DCF and SCM muscles demonstrated an increase in recruitment with each progressive phase of the test. In comparing the different pressure increments, the most significant changes found in DCF thickness were between phase 2 and phase 3 (p<.05). However no differences were found between pressure increments for SCM thickness (p>.05). Conclusion : The results suggest 26 mm Hg as the optimal pressure level during cranio-cervical flexion exercise for facilitation of deep cervical flexor.

Intra- and Inter-Rater Reliability of Thickness Measurement of the Psoas Major Muscle Using the Spring Gauge Technique for the Consistent Inward Pressures on Healthy Subjects: An Ultrasonographic Study

  • Jeon, In-Cheol;Kim, Yong-Wook;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.65-72
    • /
    • 2013
  • The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurement of the psoas major (PM) using ultrasonography (US) conducted at different inward pressures of approximately .5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Twelve healthy male subjects were recruited for the study. The thicknesses of both PMs of each subject were measured by two different examiners in a random manner to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability and ICC (3,1) was used to assess the intra-rater reliability of the MT measurement of the PM. The results indicated higher ICC values for intra-rater reliability compared to inter-rater reliability. In addition, the value for intra-rater reliability with .5 kg inward pressure [ICC=.99 (95%CI=.98~.99)] was higher compared to 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability in current study were also demonstrated to have excellent values (ICC=.94~.99). These findings showed that maintaining consistent inward pressure is essential for maintaining reliability of the results when the MT of the PM is measured by different examiners in a clinical setting.

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

Which exercise is the most effective to contract the core muscles: abdominal drawing-in maneuver, maximal expiration, or Kegel exercise? (코어 안정화를 위한 운동의 효과 비교: 복부 드로우 인 기법, 최대 호기, 케겔 운동)

  • Kim, Ji-Seon;Kim, Yang-Hyun;Kim, Eun-Na;Kim, Chae-Rin;Seo, Dong-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 2016
  • PURPOSE: There are several methods, such as the abdominal drawing-in maneuver (ADIM), maximal expiration (ME), and Kegel exercise, to strengthen the core muscles. However, to date no study has been conducted to compare the effects of the ADIM, ME, and Kegel exercise on the transverses abdominis (TrA), internal oblique (IO), external oblique (EO), and pelvic floor muscles (PFMs). The purpose of this study was to find out which of the three aforementioned exercises is most effective for contracting the core muscles. METHODS: The thickness of the TrA, IO, EO and PFMs was measured by ultrasonographic imaging during the ADIM, ME and Kegel exercise in 34 healthy participants. RESULTS: There was the significant difference between ADIM and Kegel exercise in the thickness of the TrA (p<0.05). There were the significant differences between ADIM and ME and between ME and Kegel exercise in the thickness of the IO and PFM (p<0.01). There was no significant activation in the thickness of the EO (p>0.05). Measurement reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). An ICC value of >0.77 indicated that reliability measurements was good. CONCLUSION: Kegel exercise was the most effective exercise for the TrA and the PFM, and ME was the most effective exercise for the IO muscles.

Relationship between Body Condition Score and Ultrasonographic Measurement of Subcutaneous Fat in Dairy Cows

  • Zulu, Victor Chisha;Nakao, Toshihiko;Moriyoshi, Masaharu;Nakada, Ken;Sawamukai, Yutaka;Tanaka, Yoshinobu;Zhang, Wen-Chang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.6
    • /
    • pp.816-820
    • /
    • 2001
  • This study aimed at relating body condition score (BCS) to ultrasound measurements of subcutaneous fat over the areas most commonly used to BCS Holstein-Friesian cows, and determining the practicality of ultrasound measurement of subcutaneous fat for assessment of energy status of the cow. Twenty-eight cows were scored to the nearest quarter point on a scale of 1-5 (1=thin and 5=fat) using both visual and tactile techniques. On the same day, ultrasound measurements of subcutaneous fat were obtained at the lumbar transverse process, thurl and near the tailhead areas on both sides of the cow making six locations. Spearman's rank correlation coefficients between the six ultrasound locations ranged from 0.72-0.93 and were all significantly different from zero (p<0.01). Correlation coefficients between BCS and the mean lumbar, thurl and tailhead ultrasound measurements ranged between 0.67-0.72 and were also significantly different from zero (p<0.01). BCS was highly and significantly correlated to ultrasound measurements of subcutaneous fat. Ultrasound can be used independently or in conjunction with BCS to estimate the nutrition and energy status of cows.