Browse > Article
http://dx.doi.org/10.18857/jkpt.2016.28.2.119

Reliability of Thickness Measurements of the Abductor Hallucis Muscle Using the Spring Gauge Technique in Hallux Valgus Subjects: An Ultrasonographic Study  

Jeon, In-cheol (Department of Physical Therapy, Graduate School, Yonsei University)
Kim, Moon-Hwan (Department of Rehabilitation Medicine, Wonju Severance Christian Hospital)
Publication Information
The Journal of Korean Physical Therapy / v.28, no.2, 2016 , pp. 119-123 More about this Journal
Abstract
Purpose: The purpose of this study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurements of the abductor hallucis (AbdH) in subjects with hallux valgus (HV), using ultrasonography performed at different inward pressures of approximately 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg, with no pressure control. Methods: Thirty-two subjects with HV were recruited. The thicknesses of both sides of the AbdH were measured randomly by two different examiners for assessment of the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability of MT measurements of the AbdH, while ICC (3,1) was used to assess the intra-rater reliability. Results: The results showed higher ICC values for intra-rater reliability compared to inter-rater reliability, and the value for inter-rater reliability with no pressure control (ICC=0.74 [95%CI=0.53-0.87]) was smaller compared to pressures of 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability also showed excellent values (ICC=0.86-0.96). Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results in measurement of the MT of the AbdH by different examiners in a clinical setting.
Keywords
Reliability; Inward pressure; Abductor hallucis; Hallux valgus; Ultrasonography;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Aiyer A, Stewart S, Rome K. The effect of age on muscle characteristics of the abductor hallucis in people with hallux valgus: A cross-sectional observational study. J Foot Ankle Res. 2015;8:19.   DOI
2 Agawany AE, Meguid EA. Mode of insertion of the abductor hallucis muscle in human feet and its arterial supply. Folia Morphol (Warsz). 2010;69(1):54-61.
3 Reeser LA, Susman RL, Stern JT Jr. Electromyographic studies of the human foot: Experimental approaches to hominid evolution. Foot Ankle. 1983;3(6):391-407.   DOI
4 Wong YS. Influence of the abductor hallucis muscle on the medial arch of the foot: A kinematic and anatomical cadaver study. Foot Ankle Int. 2007; 28(5):617-20.   DOI
5 Kim MH, Koh EK, Jung DY. Analysis of Kinematic Motions of First Metatarsophalangeal Joint during Electrical Stimulation of Abductor Hallucis Muscle in Subjects with Hallux Valgus. J Korean Soc Phys Ther. 2012;24(4):276-81.
6 Sarwark JF. Essentials of Musculoskeletal Care, 4th ed. Illinois. American Academy of Orthopaedic Surgeons, 2010:425-44.
7 Eustace S, Williamson D, Wilson M et al. Tendon shift in hallux valgus: observations at MR imaging. Skelet Radiol. 1996;25(6):519-24.   DOI
8 Stewart S, Ellis R, Heath M et al. Ultrasonic evaluation of the abductor hallucis muscle in hallux valgus: A cross-sectional observational study. BMC Musculoskelet Disord. 2013;14:45-50.   DOI
9 Fukumoto Y, Ikezoe T, Yamada Y et al. Skeletal muscle quality assessed from echo intensity is associated with muscle strength of middle-aged and elderly persons. Eur J Appl Physiol. 2012;112(4):1519-25.   DOI
10 Santaguida PL, McGill SM. The psoas major muscle: A three-dimensional geometric study. J Biomech. 1995;28(3):339-45.   DOI
11 Cameron AF, Rome K, Hing WA. Ultrasound evaluation of the abductor hallucis muscle: Reliability study. J Foot Ankle Res. 2008;1(1):12.   DOI
12 Bemben MG. Use of diagnostic ultrasound for assessing muscle size. J Strength Cond Res. 2002;16(1):103-8.
13 Ishida H, Watanabe S. Influence of inward pressure of the transducer on lateral abdominal muscle thickness during ultrasound imaging. J Orthop Sports Phys Ther. 2012;42(9):815-8.   DOI
14 Cagnie B, Derese E, Vandamme L et al. Validity and reliability of ultrasonography for the longus colli in asymptomatic subjects. Man Ther. 2009;14(4):421-6.   DOI
15 Crossley KM, Bennell KL, Cowan SM et al. Analysis of outcome measures for persons with patellofemoral pain: Which are reliable and valid? Arch Phys Med Rehabil. 2004;85(5):815-22.   DOI
16 Bohannon RW, Andrews AW. Accuracy of spring and strain gauge hand-held dynamometers. J Orthop Sports Phys Ther. 1989;10(8):323-5.   DOI
17 Hing WA, Rome K, Cameron AF. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines. J Foot Ankle Res.2009 16;2:33.   DOI
18 Bunce SM, Moore AP, Hough AD. M-mode ultrasound: A reliable measure of transversus abdominis thickness? Clin Biomech (Bristol, Avon). 2002;17:315-7.   DOI