• 제목/요약/키워드: ultrasonographic features

검색결과 57건 처리시간 0.023초

Ultrasonographic Indeterminate Lymph Nodes in Preoperative Thyroid Cancer Patients: Malignancy Risk and Ultrasonographic Findings Predictive of Malignancy

  • Roh-Eul Yoo;Ji-hoon Kim;Jeong Mo Bae;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Seung Hong Choi;Chul-Ho Sohn;Jung Hyo Rhim;Sun-Won Park
    • Korean Journal of Radiology
    • /
    • 제21권5호
    • /
    • pp.598-604
    • /
    • 2020
  • Objective: Proper management of lymph nodes (LNs) with ultrasonographic (US) indeterminate features in thyroid cancer patients remains elusive. We aimed to evaluate the malignancy risk and US findings predictive of malignancy for US indeterminate LNs in preoperative thyroid cancer patients through node-by-node correlation. Materials and Methods: A total of 348 LNs in 284 thyroid cancer patients, who underwent fine-needle aspiration or core-needle biopsy between December 2006 and June 2015, were included. We determined the malignancy risks for US probably benign, indeterminate, and suspicious categories. For US indeterminate LNs, which had neither echogenic hilum nor hilar vascularity in the absence of any suspicious finding, US findings were compared between benign and metastatic LNs using Mann-Whitney U test and Fisher's exact test. Results: US imaging diagnoses were probably benign in 20.7% (n = 72) cases, indeterminate in 23.6% (n = 82), and suspicious in 55.7% (n = 194). Malignancy risk of US indeterminate LNs (19.5% [16/82]) differed from those of the US probably benign (2.8% [2/72]) (p = 0.002) and US suspicious LNs (78.4% [152/194]) (p < 0.001). Among US indeterminate LNs, there were no significant differences in short, long, and long-to-short diameter (L/S) ratios between benign and metastatic LNs (3.9 vs. 3.8 mm, p = 0.619; 7.3 vs. 7.3 mm, p = 0.590; 1.9 vs. 1.9, p = 0.652). Conclusion: US indeterminate LNs were frequently encountered during preoperative evaluation and had intermediate malignancy risk. Given the lack of discriminative power of size criteria and L/S ratio, clinical factors such as surgical strategy and node size should be considered for proper triage of US indeterminate LNs in thyroid cancer.

Ultrasonographic findings of mesenchymal chondrosarcoma of the mandible: report of a case

  • Shahidi, Shoaleh;Shakibafard, Alireza;Zamiri, Barbod;Mokhtare, Mohammad Reza;Houshyar, Maneli;Houshyar, Maral;Amanpour, Sara
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.115-119
    • /
    • 2012
  • Today, ultrasound imaging is being widely used to assess soft tissue lesions in the maxillofacial region. However, ultrasound investigations of intra-osseous lesions are rare, especially for tumors of the jaws. This report emphasized the capability of this useful imaging modality in identification of the characteristics of malignant conditions involving the bone. Mesenchymal chondrosarcoama, one of the unusual malignant conditions of the jaw, was presented in a young male with significant facial swelling. Different imaging modalities parallel with the histopathologic investigation confirmed the diagnosis. Interestingly, destruction of the bony cortex and new bone formation with a characteristic "sun ray appearance", highly suggestive of sarcomas, was manifested on the ultrasonograph. Thus, this report presented the ultrasonographic features of chondrosarcoma of mandible and considered the ultrasonography to be a useful imaging modality to evaluate intra-osseous jaw lesions.

Optimal examination for traumatic nerve/muscle injuries in earthquake survivors: a retrospective observational study

  • Berkay Yalcinkaya;Busranur Tuten Sag;Mahmud Fazil Aksakal;Pelin Analay;Hasan Ocak;Murat Kara;Bayram Kaymak;Levent Ozcakar
    • Journal of Yeungnam Medical Science
    • /
    • 제41권2호
    • /
    • pp.120-127
    • /
    • 2024
  • Background: Physiatrists are facing with survivors from disasters in both the acute and chronic phases of muscle and nerve injuries. Similar to many other clinical conditions, neuromusculoskeletal ultrasound can play a key role in the management of such cases (with various muscle/nerve injuries) as well. Accordingly, in this article, a recent single-center experience after the Turkey-Syria earthquake will be rendered. Methods: Ultrasound examinations were performed for various nerve/muscle lesions in 52 earthquake victims referred from different cities. Demographic features, type of injuries, and applied treatment procedures as well as detailed ultrasonographic findings are illustrated. Results: Of the 52 patients, 19 had incomplete peripheral nerve lesions of the brachial plexus (n=4), lumbosacral plexus (n=1), and upper and lower limbs (n=14). Conclusion: The ultrasonographic approach during disaster relief is paramount as regards subacute and chronic phases of rehabilitation. Considering technological advances (e.g., portable machines), the use of on-site ultrasound examination in the (very) early phases of disaster response also needs to be on the agenda of medical personnel.

Correlation of Contrast-Enhanced Ultrasonographic Features with Microvessel Density in Papillary Thyroid Carcinomas

  • Zhou, Qi;Jiang, Jue;Shang, Xu;Zhang, Hong-Li;Ma, Wen-Qi;Xu, Yong-Bo;Wang, Hua;Li, Miao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7449-7452
    • /
    • 2014
  • Background: The purpose of this study was to investigate the correlation of contrast-enhanced ultrasonographic (CEUS) features with microvessel density (MVD) in papillary thyroid carcinomas (PTCs). Materials and Methods: Contrast-enhanced ultrasonography (CEUS) was performed in 62 patients (17 men and 45 women) with PTC. Tomtec software was applied to analyze the time intensity curve of CEUS. Immunohistochemistry was performed to evaluate the level of MVD in papillary thyroid carcinoma. Then the relationship between quantitative feature and the level of MVD was analyzed using SPSS 16.0 software. Results: The mean peak intensity of PTC tissues was lower than that of peripheral thyroid parenchyma ($61.9{\pm}11.8%$ vs 100%, p<0.05). The MVDs of CD34 and CD31 antibodies staining were $38.0{\pm}6.1$ and $37.9{\pm}5.1$ respectively in 62 PTC samples. A significantly positive correlation was observed between peak intensity and MVD in PTC tissues ($P_{CD34}$<0.01, $r_{CD34}$=0.838, $P_{CD31}$<0.01, $r_{CD31}$=0.837). Conclusions: The peak intensity in CEUS could reflect the MVD in PTC tissues. Therefore, quantification of CEUS seems to be helpful for assessment of MVD in PTC tissues.

Ultrasonographic Features of Triple-Negative Breast Cancer: a Comparison with Other Breast Cancer Subtypes

  • Yang, Qi;Liu, Hong-Yan;Liu, Dan;Song, Yan-Qiu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3229-3232
    • /
    • 2015
  • Background: Triple-negative breast cancer (TNBC) is known to be associated with aggressive biologic features and a poor clinical outcome. Therefore, early detection of TNBC without missed diagnosis is a requirement to improve prognosis. Preoperative ultrasound features of TNBC may potentially assist in early diagnosis as characteristics of disease. Purpose: To retrospectively evaluate the sonographic features of TNBC compared to ER (+) cancers which include HER(-) and HER2 (+), and HER2 (+) cancers which are ER (-). Materials and Methods: From June 2012 through June 2014, sonographic features of 321 surgically confirmed ER (+) cancers (n=214), HER2 (+) cancers (n=66), and TNBC (n=41) were retrospectively reviewed by two ultrasound specialists in consensus. The preoperative ultrasound and clinicopathological features were compared between the three subtypes. In addition, all cases were analyzed using morphologic criteria of the ACR BI-RADS lexicon. Results: Ultrasonographically, TNBC presented as microlobulated nodules without microcalcification (p=0.034). A lower incidence of ductal carcinoma in situ (p<0.001), invasive tumor size that is>2 cm (p=0.011) and BI-RADS category 4 (p<0.001) were significantly associated with TNBC. With regard to morphologic features of 41 TNBC cases, ultrasonographically were most likely to be masses with irregular (70.7%) microlobulated shape (48.8%), be circumscribed (17.1%) or have indistinct margins (17.1%) and parallel orientation (68.9%). Especially TNBC microlobulated mass margins were more more frequent than with ER (+) (2.0%) and HER2 (+) (4.8%) cancers. Conclusions: TNBC have specific characteristic in sonograms. Ultrasonography may be useful to avoid missed diagnosis and false-negative cases of TNBC.

Ultrasonographic Evaluation of Diffuse Thyroid Disease: a Study Comparing Grayscale US and Texture Analysis of Real-Time Elastography (RTE) and Grayscale US

  • Yoon, Jung Hyun;Lee, Eunjung;Lee, Hye Sun;Kim, Eun-Kyung;Moon, Hee Jung;Kwak, Jin Young
    • International journal of thyroidology
    • /
    • 제10권1호
    • /
    • pp.14-23
    • /
    • 2017
  • Background and Objectives: To evaluate and compare the diagnostic performances of grayscale ultrasound (US) and quantitative parameters obtained from texture analysis of grayscale US and elastography images in evaluating patients with diffuse thyroid disease (DTD). Materials and Methods: From September to December 2012, 113 patients (mean age, $43.4{\pm}10.7years$) who had undergone preoperative staging US and elastography were included in this study. Assessment of the thyroid parenchyma for the diagnosis of DTD was made if US features suggestive of DTD were present. Nine histogram parameters were obtained from the grayscale US and elastography images, from which 'grayscale index' and 'elastography index' were calculated. Diagnostic performances of grayscale US, texture analysis using grayscale US and elastography were calculated and compared. Results: Of the 113 patients, 85 (75.2%) patients were negative for DTD and 28 (24.8%) were positive for DTD on pathology. The presence of US features suggestive of DTD showed significantly higher rates of DTD on pathology, 60.7% to 8.2% (p<0.001). Specificity, accuracy, and positive predictive value was highest in US features, 91.8%, 84.1%, and 87.6%, respectively (all ps<0.05). Grayscale index showed higher sensitivity and negative predictive value (NPV) than US features. All diagnostic performances were higher for grayscale index than the elastography index. Area under the curve of US features was the highest, 0.762, but without significant differences to grayscale index or mean of elastography (all ps>0.05). Conclusion: Diagnostic performances were the highest for grayscale US features in diagnosis of DTD. Grayscale index may be used as a complementary tool to US features for improving sensitivity and NPV.

개에서 복강내 잔존한 거즈 이물의 진단영상 (Diagnostic Imaging Features of Abdominal Foreign Body in Dogs; Retained Surgical Gauze)

  • 최지혜;김계동;계서연;장재영;최희연;윤정희
    • 한국임상수의학회지
    • /
    • 제28권1호
    • /
    • pp.94-100
    • /
    • 2011
  • This study was performed to describe the radiographic and ultrasonographic features of retained surgical gauze known as gossypiboma in 9 dogs. Female dogs (n = 8) were at higher risk and seven out of the eight cases had a history of ovariohysterectomy. Seven dogs were symptomatic and the most common clinical signs were vomiting, anorexia, and inertia. A palpable abdominal mass was detected in six dogs. Radiographic signs included a localized abdominal mass with soft tissue density (n = 7) or a mass containing speckled gas (n = 1). Ultrasonography showed a hypoechoic mass with a hyperechoic center (n = 4), or a homogeneous hypoechoic mass (n = 3). The remaining dogs (n = 2) showed an intestinal wall surrounding a hyperechoic center. Regardless of the characteristics of a mass, an acoustic shadowing was accompanied from the center of a mass in all dogs. Ultrasonography also revealed complications such as adhesion between a mass and adjacent organs, and peritonitis and intestinal obstruction around a mass. The gossypiboma can be considered when a hypoechoic mass accompanying a hyperechoic center with acoustic shadowing is observed on ultrasound examination.

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권3호
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

미성숙 미니돼지에서 방사선과 초음파를 이용한 복부장기의 평가 (Evaluation of Normal Abdominal Organs by Diagnostic Imaging in the Premature Miniature Pig)

  • 장진화;정주현;오선경;최민철
    • 생명과학회지
    • /
    • 제19권3호
    • /
    • pp.417-421
    • /
    • 2009
  • 4, 8, 12, 20 주령의 미성숙 미니돼지에서 방사선과 초음파를 이용하여 복부 주요 장기의 형태학적 특징을 살펴보았다. 방사선 검사는 전반적인 장기의 형태를 확인하는 데 이용되는 가장 기본적이고 단순한 방법이다. 기본 복부방사선 사진에서 이용되는 평가해야 할 항목들은 우선 전반적인 복부세부음영의 정도, 간, 위, 비장, 신장, 방광, 장들의 위치, 크기, 형태, 변연, 후복강 평가이다. 초음파 검사는 이러한 주요 장기들의 내부 실질을 평가하는 데 주로 사용된다. 미니돼지는 개와 고양이와 비교했을 때 유사한 소견을 가진 것을 확인하였다.

개에서 발생한 연부조직 섬유종 2례 (Soft Tissue Fibroma in Two Dogs)

  • 최호정;이정우;안지영;오이세;안세준;정성목;박성준;조성환;이영원
    • 한국임상수의학회지
    • /
    • 제25권5호
    • /
    • pp.424-428
    • /
    • 2008
  • A 10-year-old castrated male Schnauzer (case 1) and a 13-year-old intact male Schnauzer (case 2) was referred with mass of left hind limb. We performed hemogram, serum chemistry, radiography, ultrasonography, computed tomography, fine needle aspiration and histopathology. The complete blood counts and serum biochemistry results were within the reference range. Radiography showed cutaneous mass with soft tissue density. The lesions of two dogs were revealed a definite marginated hyperechoic mass with vascularization in ultrasonography. Computed tomography showed an isodense mass in the left hind limb region with minimal contrast enhancing in case 1 and heterogenous enhancement in case 2. Cytology from ultrasonographic guided aspiration of the mass was suspected fibrous tissue-derived benign cell in two dogs. A surgical excision was performed in two dogs. In histological examination of the resected mass, cutaneous fibroma was revealed. The two patients were successfully treated by surgery and postoperative care. This report decribes and compares radiographic, ultrasonographic, computed tomographic, cytologic and histopathologic features of the cutaneous fibroma of two schnauzer dogs.