• Title/Summary/Keyword: ultrasonic washing

Search Result 47, Processing Time 0.024 seconds

Adsorptive Preconcentration and ICP-AES Determination for Trace Amount of Ni(II) and Zn(II) in Aqueous Solution (수용액 중 극미량 니켈(II)과 아연(II)의 흡착농축 및 ICP-AES 정량에 관한 연구)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.73-78
    • /
    • 2005
  • A determination method of trace Ni(II) and Zn(II) in aqueous solution was studied and developed by adsorbing on titanium dioxide. For this purpose, several conditions were optimized such as the pH of sample solution, adsorption time, the types and concentration acid, and desorption time. The titanium dioxide was added in sample solution which was pH adjusted. Then, the sample solution was stirred for 5 minutes. This mixture was stored in room temperature for 30 minutes to allow adsorption. After filtering and washing the titanium dioxide, the analytes were dissolved from the titanium dioxide on membrane filter by an ultrasonic vibration for 10 minutes in 1.0 M $HNO_3$ solution. Then, this sample solution was analysed using ICP-AES. The adsorption equilibrium was achieved in 30 minutes. The desorption was the most of effective with 1.0 M(mol/l) nitric acid solution, and desorption time was 10 minutes. This procedure was applied for the analysis of two real samples, i.e., brown seaweed and tangle. The recoveries of Ni(II) and Zn(II) in spiked samples were 89.4${\sim}$98.9% for analytes.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Study in the Development of Motion Recognition Tap-water using Ultrasonic Sensors (초음파 센서를 이용한 모션 인식 수도꼭지 개발 및 연구)

  • Kim, Dong-Hyun;Ryu, Jae-Hoo;Ju, Jong-Soo;Ahn, Jong-Pil;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.309-316
    • /
    • 2022
  • Advances in technology have improved people's lives comfortably and have developed more easily, safely and simply. We usually turn on hot water to set the temperature of the water in the bathroom and gradually adjust the temperature to find the temperature we want with our skin. In this situation, I thought, "What if there is a device that can see the temperature of water with my eyes and help with the interior of the bathroom while including a safe system," and tried to create a system that values stability. For example, if a child accidentally changes the temperature of the water to high temperature while washing, he or she can get burned. And the biggest purpose is to secure better safety by adding LCDs and LEDs so that we can visually know the temperature before feeling it tactilely. As a result of the experiment, there was no error between the temperature detected by the water temperature sensor and the temperature displayed on the LCD, and no error occurred up to 27 cm in the distance measurement experiment using the ultrasonic sensor. There has been an error of about 2% since 28cm or older, but there is no significant inconvenience in using it within the category of faucets.

A Study on the In situ Regeneration Effects of Commercial Deactivated SCR Catalyst (상용 탈질 SCR 폐촉매의 현장 재생 효과 고찰)

  • Park, Hea-Kyung;Jun, Min-Kee;Kim, Moon-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.664-670
    • /
    • 2012
  • A study on the in situ regeneration effect of commercial deactivated SCR catalyst which had been exposed to the off gas from the heavy oil fired power plant for a long time was carried out in a simulated in situ conditions by washing with distilled water and various acid solutions in a short time. The catalytic performance test of the regenerated SCR catalysts was carried out in the micro reactor with simulated off gas of the heavy oil fired power plant and all prepared catalysts were characterized by BET, Porosimeter, EDX (Energy Dispersive X-ray spectrometer) and ICP (Inductively Coupled Plasma) to investigate correlations between catalytic activity and surface characteristics of them. The characterization results of the regenerated catalysts showed that the specific surface area was restored 95% more than that of fresh catalyst. Under this study, the activity of the regenerated catalysts with acid solution (3~6 M) without using ultrasonic wave in a simulated in situ conditions was restored 90% more than that of the fresh catalyst. It was found that improved activity of regenerated catalyst was caused by removing the deactivating materials from the surface of the deactivated SCR catalyst through acid washing.

Current conditions regarding dental infection management recognition of students in the department of dental hygiene (치위생(학)과 학생의 치과감염관리에 관한 인식현황)

  • Lee, Yeun-Kyoung;Kim, Soon-Duck
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.468-478
    • /
    • 2009
  • This research was performed to provide basic data for the development of infection related dental hygiene studies by surveying the current condition of recognition among students in the department of dental hygiene toward hospital infection management while receiving the following results by using a personal self-administered survey method targeting 303 students in the department of dental hygiene from certain areas. 1. With the current condition of recognition on the sanitization and sterilization of instruments among students in the department of dental hygiene(study), the rate at which surgical instruments are to be sterilized with autoclaves was 79.9% which was relatively higher than other instruments while it was shown that prosthetic instruments for treatment was 56.4%, conservative instruments for treatment was 51.8%, and ultrasonic scaler tip was 51.1% while the way syringe tips(36.1%) and the dental anesthetic apparatus(27.9%) were revealed to require sanitization by alcohol. 2. The 'hand wash' area was the highest with 4.71 while the 'materials and environment management' area and 'equipment management' area appeared high respectively with 4.43 and 4.41. 3. With the current condition of recognition on equipment management, 'equipments used for contagious patients are separately washed after a one-time use and must be sterilized or separated-and-discarded' was the highest with 4.82 while 'sterilization equipments with humidity or water on it are considered contaminated and are not used' showed the lowest recognition level with 3.90. 4. Regarding the current condition of materials and environment management, 'contagious and general trash are separated and discarded' was the highest with 4.70 while 'the refrigerator for medicine storage is cleaned on a regular basis once a month' was revealed as the lowest with 4.11. 5. With the current condition of recognition on hand washing, 'one must wash their hands after coming in contact with contagious patients, was the highest with 4.90 while washing hands after taking off gloves' appeared as the lowest with 4.51 point. To conclude department of dental hygiene there is to infection management and necessary about organization disinfecting and pasteurization to strengthen an education in order raising a stamp helping practical ratio about the infection management which whole, is from presence at a sickbed and connection does and about the infection management which is substantial and educational program development leads feed with the fact that deepening studying which is continuous must become accomplished becomes.

  • PDF

Improving Dyeability of Safflower Yellow Colorants on Cellulose Fibers (홍화 황색소의 셀룰로오스 섬유에 대한 염착성 증진)

  • Shin, Youn-Sook;Cho, A-Rang;Yoo, Dong-Il
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.12
    • /
    • pp.1754-1760
    • /
    • 2007
  • To improve poor dye uptake of safflower yellow colorants, cellulose fibers were pretreated with chitosan. The effect of chitosan pretreatment on the dyeability of safflower yellow colorants to cotton, ramie, and rayon was investigated in terms of dye uptake, color, and colorfastness. Irrespective of fiber types, dye uptake increased continuously with increase in chitosan concentration. Chitosan pretreatment improved dye uptake up to 5.6 times for cotton, 7.2 times for ramie, and 3.7 times for rayon. For cotton and ramie, the shade of dyed fabric changed YR color to Y color with increase in chitosan concentration. Dyed rayon fabrics showed Y color irrespective of chitosan concentration. Shades got darker and deeper with increasing chitosan concentration. Shades of chitosan pretreated fabrics were shifted differently depending on dyeing temperature within same fabrics. In common, the color of all dyed fabrics changed to YR at 50 and $70^{\circ}C$ while Y color at 30 and $90^{\circ}C$. V and C value decreased with increase in dyeing temperature and resulted in darker and duller color, in general. Light fastness was fair while washing fastness was poor. It was confirmed that ultrasonic dyeing method enhanced dye uptake more than 30% for cotton and ramie fabrics compared to the conventional automatic machine dyeing method. However, no difference in dye uptake between two dyeing methods was found for rayon.

Increased Sensitivity of Carbon Nanotube Sensors by Forming Rigid CNT/metal Electrode

  • Park, Dae-Hyeon;Jeon, Dong-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.348-348
    • /
    • 2011
  • Carbon nanotube (CNT) field effect transistors and sensors use CNT as a current channel, of which the resistance varies with the gate voltage or upon molecule adsorption. Since the performance of CNT devices depends very much on the CNT/metal contact resistance, the CNT/electrode contact must be stable and the contact resistance must be small. Depending on the geometry of CNT/electrode contact, it can be categorized into the end-contact, embedded-contact (top-contact), and side-contact (bottom-contact). Because of difficulties in the sample preparation, the end-contact CNT device is seldom practiced. The embedded-contact in which CNT is embedded inside the electrode is desirable due to its rigidness and the low contact resistance. Fabrication of this structure is complicated, however, because each CNT has to be located under a high-resolution microscope and then the electrode is patterned by electron beam lithography. The side-contact is done by depositing CNT electrophoretically or by precipitating on the patterned electrode. Although this contact is fragile and the contact resistance is relatively high, the side-contact by far has been widely practiced because of its simple fabrication process. Here we introduce a simple method to embed CNT inside the electrode while taking advantage of the bottom-contact process. The idea is to utilize a eutectic material as an electrode, which melts at low temperature so that CNT is not damaged while annealing to melt the electrode to embed CNT. The lowering of CNT/Au contact resistance upon annealing at mild temperature has been reported, but the electrode in these studies did not melt and CNT laid on the surface of electrode even after annealing. In our experiment, we used a eutectic Au/Al film that melts at 250$^{\circ}C$. After depositing CNT on the electrode made of an Au/Al thin film, we annealed the sample at 250$^{\circ}C$ in air to induce eutectic melting. As a result, Au-Al alloy grains formed, under which the CNT was embedded to produce a rigid and low resistance contact. The embedded CNT contact was as strong as to tolerate the ultrasonic agitation for 90 s and the current-voltage measurement indicated that the contact resistance was lowered by a factor of 4. By performing standard fabrication process on this CNT-deposited substrate to add another pair of electrodes bridged by CNT in perpendicular direction, we could fabricate a CNT cross junction. Finally, we could conclude that the eutectic alloy electrode is valid for CNT sensors by examine the detection of Au ion which is spontaneously reduced to CNT surface. The device sustatined strong washing process and maintained its detection ability.

  • PDF