• Title/Summary/Keyword: ultrasonic transducers

Search Result 252, Processing Time 0.025 seconds

A Study on the Actual Output and Thermal Effect in Tissue Mimicking Phantom by the Material of the Ultrasonic Transducer (초음파트랜스듀서의 재질에 따른 실출력과 인체모사조직의 온열효과에 관한 연구)

  • Yoo, Sang-Hyun;Choi, Won-Jae;Lee, Seung-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2015
  • PURPOSE: In this study investigated the thermal effect in tissue mimicking phantom by the material of the ultrasonic transducer in low intensity sonication. METHODS: The material of the ultrasonic transducer was made of ceramic, stainless steel, aluminum. Korea Testing Laboratory was measured of the three kinds of materials the total output of the ultrasonic transducer. Each material was measured core temperature and the actual output depending on the type of transducer. Agarose tissue mimicking phantom and silicone tissue mimicking phantom was made. Transducers made of three kinds of materials were emitted in the phantom. It is shown as a graph about time and temperature and the surface temperature rising speed and deep temperature rise rate was investigated. RESULTS: Ceramic transducers were highest output. Higher than the stainless steel transducer, aluminum had the lowest total output. Deep temperature was the highest in the ceramic transducer, and the surface temperature was the highest in the stainless steel transducer. Thermal images of ceramic transducer showed that a valid output is formed deeper wider than the metal. CONCLUSION: Ceramic transducer is confirmed the excellence than the metal transducer in deep thermal effect and the actual output of the ultrasound.

Elastic Modulus of Magnetic Fluids Evaluated by Ultrasonic Test (초음파 시험에 의한 자기유체의 탄성율 산정)

  • Kim, Jong-Hee;Kim, Kun-Woo;Kim, Cheol-Gi;Lee, Seung-Goo;Koo, Man-Hoi
    • Korean Journal of Materials Research
    • /
    • v.22 no.3
    • /
    • pp.136-139
    • /
    • 2012
  • Magnetic nanoparticles for ferromagnetic fluids and magnetorheological fluids were prepared by chemical coprecipitation and mechanical milling, respectively. The surface-treated particles were dispersed at various weight ratios into a medium of polyethylene glycol. In order to evaluate the elastic modulus of the fluids, ultrasonic pulse velocities were measured with an ultrasonic test using transducers of 5MHz and 2.25MHz. The ultrasonic signals were only available with a transducer of 2.25 MHz at fluid concentrations of 5 mg/ml and lower. In the case of applying transducers over 2.25 MHz and concentrations over 5 mg/ml to the fluids, it was impossible to observe effective ultrasonic signals due to an excessive scattering of the pulses by the dispersed particles. Elastic moduli of the magnetorheological fluids were 5.44 GPa and 6.13 GPa with concentrations of 25 mg/ml and 50 mg/ml, respectively; these values were higher by 40% than the values of 4.04 GPa and 4.28 GPa of ferromagnetic fluids at the same concentrations. As for the effect of an external magnetic field on these dilute fluids, the ultrasonic signals were positioned in a very similar way, which was probably due to insufficient arrangement of the particles even though the reflection energy of the ultrasonic waves apparently increased.

Characterization of Component Materials of the Ultrasonic Transducer (초음파 탐촉자 구성 재료의 특성 연구)

  • Kim, B.G.;Park, Y.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1989
  • Piezoelectric elements, backing and shoe material are the important components of the ultrasonic transducer. In this study, characteristic constants in the domestic and the foreign PZT ceramic elements are investigated, The acoustic properties of the domestic and the foreign backing and shoes are characterized. The effects of components characteristics, the kinds of the piezoelectric elements and the thickness of the wear plates are investigated for the manufactured normal beam ultrasonic transducers.

  • PDF

Poisson's Ratio Measurement Using a Pair of PVDF Ultrasonic Transducer

  • Vargas, Enrique;Toral, Sergio;Gonzalez, Vicente
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.519-524
    • /
    • 2009
  • This work presents a simple technique to determine the Poisson's ratio of homogeneous solid material using a pair of low cost PVDF ultrasonic transducers. It is based on transducer's property of generating longitudinal and transversal waves depending on the excitation frequency. Mechanical tests were conducted to validate the proposed method, resulting in a good agreement between ultrasonic and mechanical techniques.

Analytical Beam Field Modeling Applied to Transducer Optimization and Inspection Simulation in Ultrasonic Nondestructive Testing

  • Spies, Martin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.635-644
    • /
    • 2003
  • To ensure the reliability of ultrasonic nondestructive testing techniques for modern structural materials, the effects of anisotropy and inhomogeneity and the influence of non-planar component geometries on ultrasonic wave propagation have to be taken into account. In this article, fundamentals and applications of two analytical approaches to three-dimensional elastic beam field calculation are presented. Results for both isotropic materials including curved interfaces and for anisotropic media like composites are presented, covering field profiles for various types of transducers and the modeling of time-dependent rf-signals.

Welding Residual Stress Measurement by Ultrasonic Method (초음파를 이용한 용접잔류응력 측정기술)

  • Lee, S.S.;Ahn, B.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.2
    • /
    • pp.61-66
    • /
    • 1989
  • Welding residual stress was measured by ultrasonic birefringence technique. Acoustoelastic constant was taken by averaging the values in the literature. The initial birefringence from prefered orientation of grains was measured. The EMAT transducers were used to remove couplant effect. The results show that the distribution and magnitude of welding residual stress from ultrasonic measurement are in good agreements with those from semi destructive hole drilling measurement.

  • PDF

Development of New Ultrasonic Transducer for Coarse-Grained Materials (Coarse Grain 소재용 초음파 변환기 개발)

  • Kim, B.G.;Lee, J.O.;Lee, S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.18-23
    • /
    • 1990
  • In materials with the large grain size, ultrasonic waves are highly attenuated by the grain boundary acting as scattering centers due to discontinuity of elastic constant. In this study, the improved probes were developed so that they minimized the effect of grain scattering in order to detect deep flaws in coarse grained materials. As the result, the developed ultrasonic transducers showed the better sensitivity and signal to noise ratio when compared with the commercial probes in testing the interior of coarse grained material.

  • PDF

Design and Fabrication of the Spiral Coils for Guided Wave Magnetostrictive Transducers

  • Choi, Myoung-Seon;Heo, Won-Nyoung;Jun, Jong-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.496-503
    • /
    • 2008
  • We propose rectangular type spiral coils with folded comers for the applications to low frequency guided wave magnetostrictive transducers and describe a method for making the proposed coils from insulated electrical wire such as enameled copper wire. Expressions for the electrical properties of the coils are also presented and compared with experimental measurements. An overlapped-2-channel folded-comer spiral-coil array is fabricated and applied to a magnetostrictive strip transducer generating and detecting fundamental torsional mode guided waves. From the results we conclude that the design and fabrication method make it possible to use the magnetostrictive transducers optimized for various guided wave applications and also will greatly help engineers gain easy access to the optimized transducers.

Design and Fabrication of 2D Array Ultrasonic Transducers with a Conductive Backer (전도성 후면층을 이용한 2D 배열 초음파 트랜스듀서의 설계 및 제작)

  • Woo, Jeongdong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.502-508
    • /
    • 2013
  • In this paper, 2D array transducers using a conductive backer similar to 1-3 composites have been designed, fabricated, and evaluated. The conductive backer was based on well known manufacturing process of 1-3 composites with affordable ingredients. The 2D array transducer had 4,096 elements designed to have 3.5 MHz center frequency and a fractional bandwidth over 60 %. Fabricated prototype of the transducer satisfied the specifications in the center frequency and bandwidth. Performance over the entire elements was so uniform that the standard deviation was less than 0.81 dB. Thus applicability of the conductive backer proposed in this work to 2D array transducers was verified.

Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite (PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • 박정학;최헌일;손무현;사공건
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF