• Title/Summary/Keyword: ultrasonic property

Search Result 177, Processing Time 0.028 seconds

Physical Property Change of Old Fabrics Depending on Cleaning Method (출토 직물의 세탁 방법에 따른 물성 변화)

  • 배순화;이미식
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The purpose of this study was to compare the efficiency of four different cleaning method of silk and to fabrics, which were excavated from the sixteenth century tombs. The four cleaning methods were hand washing in water and hand washing in solvent, washing in ultrasonic cleaner, and using of ultrasonic gun after washing in ultrasonic cleaner. The following is the result of the experiment: ㆍBoth silk and jute fabrics shrank the most after hand-wash in water. This cleaning method decreased their thickness the most but changed their strength the least. However, the color of the fabric changed the most after had-wash in water. This washing method might discolor the dyed fabric, so one must check the condition of the fabric thoroughly before washing it. ㆍThe weight and the thickness of the fabric changed little after ultrasonic cleaning. This cleaning method, therefore. is less efficient than hand-water-wash. The use of ultrasonic gun after ultrasonic wash for partial cleansing enhanced the efficiency a little. Nevertheless, this method left stain around the area where the gun was used, and the injected water could damage the fabric. ㆍThe excavated fabric became softer in the cleaning process as the dirt was washed away. In both cases of silk and jute fabrics cleaning, solvent made the fabric softer than water. Washed in solvent, the fabric did not swell. But water penetrated to the fiber during the cleaning process and made the fabric swell. When the water evaporates, the swollen fiber structure collapses and the fabric become stiff. Ultrasonic wash did not cause much change in the flexibility of the fabric, for this method does not remove the dirt as effectively as the other method.

A Study on the Ultrasonic Nondestructive Evaluation of Carbon/Carbon Composite Disks

  • Im, Kwang-Hee;Jeong, Hyun-Jo;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.320-330
    • /
    • 2000
  • It is desirable to perform nondestructive evaluation (NDE) to assess material properties and part homogeneity because the manufacturing of carbon/carbon brake disks requires complicated and costly processes. In this work several ultrasonic techniques were applied to carbon/carbon brake disks (322mm ad, 135mm id) for the evaluation of spatial variations in material properties that are attributable to the manufacturing process. In a large carbon/carbon disk manufactured by chemical vapor infiltration (CYI) method, the spatial variation of ultrasonic velocity was measured and found to be consistent with the densification behavior in CYI process. Low frequency (e.g., 1-5MHz) through-transmission scans based on both amplitude and time-of-flight of the ultrasonic pulse were used for mapping out the material property inhomogeneity. Images based on both the amplitude and the time-of-flight of the transmitted ultrasonic pulse showed significant variation in the radial direction. The radial variations in ultrasonic velocity and attenuation were attributed to a density variation caused by the more efficient densification of pitch impregnation near the id and od and by the less efficient densification away from the exposed edged of the disk. Ultrasonic velocities in the edges of the disk. Ultrasonic velocities in the thickness direction were also measured as a function of location using dry-coupling transducers ; the results were consistent with the densification behavior. However, velocities in the in-plane directions (circumferential and radial) seemed to be affected more by the relative contents of fabric and chopped fiber, and less by the void content.

  • PDF

Quasi-Optimal DOA Estimation Scheme for Gimbaled Ultrasonic Moving Source Tracker (김발형 초음파 이동음원 추적센서 개발을 위한 의사최적 도래각 추정기법)

  • Han, Seul-Ki;Lee, Hye-Kyung;Ra, Won-Sang;Park, Jin-Bae;Lim, Jae-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.276-283
    • /
    • 2012
  • In this paper, a practical quasi-optimal DOA(direction of arrival) estimator is proposed in order to develop a one-axis gimbaled ultrasonic source tracker for mobile robot applications. With help of the gimbal structure, the ultrasonic moving source tracking problem can be simply reduced to the DOA estimation. The DOA estimation is known as one of the representative long-pending nonlinear filtering problems, but the conventional nonlinear filters might be restrictive in many actual situations because it cannot guarantee the reliable performance due to the use of nonlinear signal model. This motivates us to reformulate the DOA estimation problem in the linear robust state estimation setting. Based on the assumption that the received ultrasonic signals are noisy sinusoids satisfying linear prediction property, a linear uncertain measurement model is newly derived. To avoid the DOA estimation performance degradation caused by the stochastic parameter uncertainty contained in the linear measurement model, the recently developed NCRKF (non-conservative robust Kalman filter) scheme [1] is utilized. The proposed linear DOA estimator provides excellent DOA estimation performance and it is suitable for real-time implementation for its linear recursive filter structure. The effectiveness of the suggested DOA estimation scheme is demonstrated through simulations and experiments.

Ultrasonic Inspection Technology of Defect Detection of Propellant/Liner Debond & Propellant Microcrack (초음파를 이용한 추진제/라이너 미접착 및 추진제 미세 크랙의 결함 검출 기법)

  • Na, Sung-Youb
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.1
    • /
    • pp.34-42
    • /
    • 2007
  • Ultrasonic inspection method is more profitable than X-ray radiographic inspection in cost and effect of defect detection such as debond, damage, and it doesn't need special constructions. The method can also be a possible real time inspection with safety. This report explains 1)the experiment and analysis of ultrasonic property of solid propellant, 2)the inspection methods of propellant/liner debond by inside or outside inspection, and 3)the inspection methods of propellant microcrack by damage. From the results, it is possible to detect the defect of propellant/liner debond by inside or outside inspection. Futhermore, it can be possible to detect the propellant microcrack caused by damage using the ultrasonic attenuation.

Study on the Debonding Detection Techniques of Liner/Propellant Interface of Rocket Motor (추진기관의 라이너/추진제 미접착 검출 기법 연구)

  • Kim, Dong-Ryun;Ryoo, Baek-Neung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.40-47
    • /
    • 2008
  • It is known that the adhesive interface testing of the rocket motor using the ultrasonic wave is superior to the other testing methods about the ability to economical detect the defects. But, the signal analysis of the ultrasonic wave takes a lot of time and efforts because the time interval of the transmitted pulse and the received pulse is too short to separate the reflected signals due to the multi-layers of the rocket motor. The ultrasonic testing of rocket motor have only applied to the automatic system about extremely limited areas like the debond in adhesive interface between the motor case and the insulator. In this study the new technique to detect the debond between the liner and the propellant using the property of the resonance and the lamb waves instead of the existing ultrasonic testing was described.

Effects of Ultrasonic Irradiation on Physical Properties of Silica/PEG Hybrids

  • Jung, Hwa-Young;Gupta, Ravindra K.;Lee, Sang-Ki;Whang, Chin-Myung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.113-119
    • /
    • 2002
  • The effect of ultrasonic radiation is reported for silica-poly(ethylene glycol) system prepared without the solvent using sol-gel processing by varying various parameters such as ultrasonic irradiation time, PEG content and HCl/TEOS molar ratio. The property of sonogel is compared with classic gel which has been prepared with ethanol as a solvent by traditional sol-gel processing. SEM, BET, DTA-TGA, density and Vickers hardness measurements are carried out for analyzing the samples. The gelation time is found strongly dependent on radiation time, PEG content and pH value, and has been discussed on the basis of existing theories. The $SiO_2-10$ & 20 wt% PEG sonogel exhibited superior optical, physical and gel properties as compared to the classic gel, hence, found suitable for device applications. The ultrasonic radiation increased the density and surface area, and also reduced the pore size which is well supported by the shift in the peak of DTA curve. The DTA thermogram was found similar to that of pure silica gel.

Study on the Debonding Detection Techniques of Liner/Propellant Interface of Rocket Motor (추진기관의 라이너/추진제 미접착 검출 기법 연구)

  • Kim, Dong-Ryun;Ryoo, Baek-Neung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.55-59
    • /
    • 2007
  • It is known that the adhesive interface testing of the rocket motor which using the ultrasonic wave iS superior to the other testing methods about the economically detectable abiliη of the defects. But, the signal analysis of the ultrasonic wave takes too much time and effort that the time interval of the transmitted pulse and the received pulse is too short to be separated the reflected signals because the structure of the rocket motor is multi-layers. The ultrasonic testing of rocket motor have been only applied with automatic system about extremely limited area like the debond in adhesive interface between the motor case and insulator. In this study the new technique to detect the debond between the liner and the propellant using the property of the resonance and Lamb waves was described as comparing the existence ultrasonic testing.

  • PDF

The analysis of the resonance characteristics of a traveling wave type ultrasonic motor by applying the normal force and driving voltage (진행파 회전형 초음파 모터의 가압력과 구동전압에 따른 공진특성의 변화 분석)

  • Oh, Jin-Heon;Park, Cheol-Hyeon;Lim, Kee-Joe;Kim, Hyeon-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.324-324
    • /
    • 2008
  • Piezoelectric ceramics is an active element that makes stator to vibrate to generate rotational force in ultrasonic motors. In drive of ultrasonic motors, many factors that affect to the resonance characteristics of piezoelectric ceramics exist. For example, those factors are bonding condition with elastic body, the magnitude of electric field, the normal force for frictional drive and the emission of heat due to vibration and friction and so on. Therefore, it is important to research the inclination of property variation of piezoelectric ceramics in circumstance that has complex elements. In this paper, we focused and analyzed the resonance characteristics of ultrasonic motor due to the magnitude of the driving voltage and normal force.

  • PDF

Design and Evaluation of Ultrasonic Bone Surgical Instruments for Dental Application (치과용 초음파 골수술기 설계 및 평가)

  • Lee, Joo-Hee;Oh, Jung-Min;Hong, Younwoo;Kim, Seiki;Paik, Jonghoo;Lee, Young-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.990-995
    • /
    • 2012
  • A piezoelectric ultrasonic bone surgical instrument, usually used to remove the tartar out of teeth or to cut the dentine of the tooth, is a recently popular instrument for dental treatment due to its several merits such as small size, low-electric power and precision control of surgical operation. It has typically two parts of a tip and vibration system which is also composed of head, piezoelectric elements and tail-mass. In order to improve the performance of the instrument, it is important to standardize the size of the vibration system without tip for high performance. In this study, a Finite Element Analysis (FEA) was utilized to optimize the structure of ultrasonic instrument in vibration system. Consequently, this study revealed that influence of several tips on property were minimized and it showed good property at the frequency range of 22~32 kHz.

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.