• Title/Summary/Keyword: ultrasonic imaging

Search Result 199, Processing Time 0.022 seconds

Elastic Imaging of Material Surface by Ultrasonic Atomic Force Microscopy (초음파 원자 현미경을 이용한 재료 표면의 탄성 이미지화)

  • Kim, C.S.;Park, Tae-Sung;Park, It-Keun;Lee, Seung-Seok;Lee, C.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.293-298
    • /
    • 2009
  • The ultrasonic atomic force microscope(UAFM) has been developed in order to enhance the characterization technology for nano-scale surface combining ultrasonic property to atomic force microscope. This UAFM technique enables elasticity imaging due to the physical properties on the heterogeneous surface in addition to the novel topography of surface height in the nano-surface layer. In this study, the prototype UAFM system was constructed and applied to several materials, silicon deposited wafer, spherodized cold heading steel, and carbon fiber reinforced plastic specimen. Clear elastic contrast was successfully obtained using this developed prototype UAFM.

Corner Inspection of Autoclave-cured L-shaped Composite Structure using Pulse-echo Rotation Scanning Scheme based on Laser Ultrasonic (레이저 초음파 기반 반사식 회전 검사 기법을 이용한 오토클레이브 가공 L 형 복합재 구조물의 모서리 검사)

  • Lee, Young-Jun;Lee, Jung-Ryul;Hong, Sung-Jin
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.246-250
    • /
    • 2018
  • In this paper, laser ultrasonic rotation scanning method was proposed to inspect and visualize defects in corner section of curved composite structure. L-shaped composite specimen with defects in its corner section were inspected using laser ultrasonic rotation scanning method. L-shaped specimens had artificial defects at three different depths to simulate delamination damage. All artificial defects were detected clearly in different time-of-flight according to their depths. Inspection result showed that the proposed method is suitable to inspect round corner section of curved composite structure without any special tools.

Medical Ultrasonic Elasticity Imaging Techniques (의료용 초음파탄성영상법)

  • Jeong, Mok-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.573-584
    • /
    • 2012
  • Breast and prostate tumors or cancers tend to be stiffer than the surrounding normal tissue. However, the difference in echogenicity between cancerous and normal tissues is not clearly distinguishable in ultrasound B-mode imaging. Thus, imaging the stiffness contrast between the two different tissue types helps to diagnose lesions quantitatively, and such a method of imaging the elasticity of human tissue is termed ultrasound elasticity imaging. Recently, elasticity imaging has become an effective complementary diagnostic modality along with ultrasound B-mode imaging. This paper presents various elasticity imaging methods that have been reported up to now and describes their characteristics and principles of operation.

A method for ultrasound image edge enhancement by using Probabilistic edge map (초음파 진단영상 대조도 개선을 위한 확률 경계 맵을 이용한 연구)

  • Choi, Woo-hyuk;Park, Won-hwan;Park, Sungyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Ultrasonic imaging is the most widely modality among modern imaging device for medical diagnosis. Nevertheless, medical ultrasound images suffer from speckle noise and low contrast. In this paper, we propose probabilistic edge map for ultrasound image edge enhancement using automatic alien algorithm. The proposed method used applied speckle reduced ultrasound imaging for edge improvement using sequentially acquired ultrasound imaging. To evaluate the performance of method, the similarity between the reference and edge enhanced image was measured by quantity analysis. The experimental results show that the proposed method considerably improves the image quality with region edge enhancement.

High Frequency Ultrasound and Its Applications to Animal and Human Imaging Focusing on Vessel and Blood (고주파 초음파의 그 응용: 혈관과 혈액을 중심으로한 동물과 인체 영상)

  • Bok, Tae-Hoon;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2E
    • /
    • pp.73-85
    • /
    • 2010
  • In the diagnostic ultrasound (US) transducer technology, the high frequency US(HFUS) transducer over 20 MHz is one of the current issues to be pursued for better resolution with the expense of penetration. HFUS single element transducers and the mechanical scanning systems for imaging are reviewed, and HFUS array transducers are also briefly summarized. HFUS applications such as the human applications in ophthalmology and dermatology and small animal applications for research purposes are reviewed with vascular and blood imaging in this paper.

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.

A study on the debelopment of the Ultrasonic imaging system for tissue characterization (조직의 정량화를 위한 초음파 영상시스템의 개발에 관한 연구)

  • Choe, Jong-Ho;Choe, Jong-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.31-42
    • /
    • 1987
  • An ultrasonic pulse-echo diagnostic system for tissue characterization with the estimation of attenuation coefficients is developed and its performance has been examined by system implementation. The system divided into the ultrasonic generator, A/D converter, data communication, computer for signal processing. The methods for estimating the spatial distribution of acoustic attenuation coefficients using the moment analysis are proposed. The experimental results indicate the potential of the methods for tissue characterization.

  • PDF

Ultrasonic Measurement of Tissue Motion for the Diagnosis of Disease

  • Beach Kirk W.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.3-12
    • /
    • 2003
  • Ultrasonic pulsed Doppler velocimetry has become a standard international method of classifying carotid disease. Because the measured angle adjusted velocity increases as the Doppler angle increases, examinations should be performed at a convenient standard Doppler examination angle. An angle of 60 degrees is achievable throughout most examinations. Multiple Doppler viewing angles allow the acquisition of velocity vectors during the cardiac cycle, revealing the complex velocity patterns. Ultrasonic velocimetry (whether Doppler or time domain) is based on changes in the phase of the ultrasound echo. Other examinations can be done based on the echo phase. Slow motions of organs such as the brain can be used to monitor changes in edema. Measurements of tissue strain due to the pulsatile filling of the arterioles. This plethysmographic imaging method can display differences in tissue perfusion because of different tissue types and changes in autonomic activity.

  • PDF

Development of Obstacle Alarm for the Visually Impaired (시각 장애인을 위한 장애물 경보기의 개발)

  • 심현민;이응혁;민홍기;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.113-116
    • /
    • 2002
  • In this paper, we propose the sound-mapping algorithm of the detected obstacle by ultrasonic sensors. We apply this algorithm to a Obstacle alarm for the visually impaired. In our system, we acquire obstacles information using ultrasonic sensors, and transform two-dimensional and distance information into sound-imaging information and vibrator with azimuth (direction) and distance. We implement this system with ultrasonic sensors to more effective expression of the obstacle information. The distance of an obstacle can be expressed by sound pressure level, and azimuth of the obstacles can be expressed by inter-aural time difference (ITD) and inter-aural level difference (ILD) that are two important cues in a binaural system. These are the principal cues for sound localization, to detect sound source. In this system, the obstacle is substituted with a sound source. The visually impaired receive sound information of obstacles by headphone.

  • PDF

A study on the measurement of Blood flow-turbulence (혈류의 Flow-Turbulence 측정에 관한 연구)

  • Ko, Yeon-Soon;Kang, Chung-Shin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.294-296
    • /
    • 1988
  • The tomographic imaging that employs ultrasonic echos has achieved outstanding advances in recent years, and today, ultrasonic diagnostic equipment has become the tool that is absolutely indispensible for clinical operations. Meanwhile, the feasility of measuring blood flow in the heart and vessels by the use of Doppler effect in ultrasonic waves is a well known fact. With respect to the method of blood flow measurment, there are two kinds which employ continous wave and pulse wave doppler system. In this paper, we describe the measurment of Blood flow-turbulence using general purpose Digital Signal Processing Board which had been implemented for the purpose of real-time spectrum analyser. Blood flow-turbulence means the blood-flow behavior. And it's value proportional to the spectrum variance. Therefore mean frequency of blood signal and variance provide useful diagnostic information. We have applied to the major arteries and vein, obtained the information about the time dependent blood-flow behavior.

  • PDF