• Title/Summary/Keyword: ultrasonic cleaning

Search Result 128, Processing Time 0.028 seconds

Effect of passive ultrasonic agitation during final irrigation on cleaning capacity of hybrid instrumentation

  • Vinhorte, Marcilene Coelho;Eduardo Hideki, Suzuki;Maira Sousa, De Carvalho;Andre Augusto Franco, Marques;Emilio Carlos Junior, Sponchiado;Lucas Da Fonseca Roberti, Garcia
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.104-108
    • /
    • 2014
  • Objectives: To evaluate the effect of passive ultrasonic agitation on the cleaning capacity of a hybrid instrumentation technique. Materials and Methods: Twenty mandibular incisors with mesiodistal-flattened root shape had their crowns sectioned at 1 mm from the cementoenamel junction. Instrumentation was initiated by catheterization with K-type files (Denstply Maillefer) #10, #15, and #20 at 3 mm from the working length. Cervical preparation was performed with Largo bur #1 (Dentsply Maillefer) followed by apical instrumentation with K-type files #15, #20 and #25, and finishing with ProTaper F2 file (Denstply Maillefer). All files were used up to the working length under irrigation with 1 mL of 2.5% sodium hypochlorite (Biodyn$\hat{a}$mica) at each instrument change. At the end of instrumentation, the roots were randomly separated into 2 groups (n = 10). All specimens received final irrigation with 1 mL of 2.5% sodium hypochlorite. The solution remained in the root canals in Group 1 for one minute; and ultrasonic agitation was performed in Group 2 for one minute using a straight tip inserted at 1 mm from working length. The specimens were processed histologically and the sections were analyzed under optic microscope (x64) to quantify debris present in the root canal. Results: The samples submitted to ultrasonic agitation (Group 2) presented significant decrease in the amount of debris in comparison with those of Group 1 (p < 0.05). Conclusions: The hybrid instrumentation technique associated with passive ultrasonic agitation promoted greater debris removal in the apical third of the root canals.

Development and performance test of a micro bubble irrigation system for root canal cleaning of tooth (치아 근관 세척용 마이크로 기포 세정 시스템 개발 및 성능평가)

  • Sung, Gilhwan;Sung, Jaeyong;Lee, Myeong Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2016
  • Elimination of the smear layer and bacteria in the root canal is the most important in the endodontic treatment, and various irrigation devices have been developed. Nevertheless, it is hard to eliminate the smear layer and bacteria completely. In this paper, a micro bubble irrigation system has been developed for the root canal cleaning of tooth. Micro bubbles are generated when pressurized fluids passing through a porous material inside a hand-piece nozzle, and the bubbly flows excited by ultrasonic vibration are observed using a high-speed camera and a microscope. The results show that the diameter and number of bubbles increases with the applied pressure, and there found an optimum excitation frequency in order to minimize the bubble size. From in-vitro tests, it is also verified that the developed bubble irrigation system has the ability of antibacterial and infection removal. Thus, this biocompatible system would be well suited for root canal cleaning.

A Study on Remanufacturing of Deactivated Commercial Diesel Oxidation Catalyst by CVS-75 mode in Light Duty Diesel Engine (비활성화된 상용 디젤 산화 촉매의 소형 디젤 기관에서 CVS-75 모드를 이용한 재제조에 관한 연구)

  • Lee, Chang-Hee;Park, Hea-Kyung
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.517-525
    • /
    • 2011
  • In this study, the used DOCs, which could remove the air pollutants such as CO and HC in the exhaust gas from diesel vehicle, were remanufactured by various conditions. Their catalytic performances and characterization were also investigated. The remanufacturing process of the deactivated DOCs includes high temperature cleaning of incineration, ultrasonic cleaning for washing with acid/base solutions to remove deactivating materials deposited to the surface of the catalysts, and active component reimpregnation for reactivating catalytic activity of them. The catalytic performance tests of the remanufactured DOCs were carried out by the diesel engine dynamo systems and chassi dynamo systems in CVS-75 mode. All prepared catalysts were characterized by the optical microscopes, SEM, EDX, porosimeter and BET to investigate correlations between catalytic reactivity and surface characteristics of them. The remanufactured DOCs at various conditions showed the improved catalytic performances reaching to 90% of fresh DOC, which is attributed to remove the deactivating materials from the surface of the used DOC through the analysis of catalytic performance test and their characterization.

A COMPARATIVE STUDY OF THE EFFECT K - FILE AND ULTRASONIC INSTRUMENT IN CLEANING AND SHAPING ROOT CANAL (K-File과 초음파기구의 근관확대 및 세척효과에 대한 비교연구)

  • Kim, Sang-Seop;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.413-420
    • /
    • 1992
  • The purpose of this study was to compare the effectiveness of hand instrumentation with K - file and ultrasonic instrumentation and irrigation system in removing pulpal debris and canal wall planing. 20 mandibular molar teeth were instrumented to size 30 K - file and 20 teeth were instrumented with ultrasonic Suprasson. And Normal Saline and 2.5% NaOCl were used as irrigation solution. All specimens were viewed at the coronal, middle, and apical third of the root canals for the evaluation of the cleaning effect under the multiview microscope. The result were as follows : 1. All of the technique and irrigation solution was effecient in the debris removal and canal wall planing at the cervical and middle thirds of the root canal. 2. All of the techniques and irrigation solutions was less efficient in the debris removal and canal planing at the apical third of the root canal. 3. The debris removal and canal wall planing was depended more on the anatomical variations of the root canal than on the techniques and irrigation solutions.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Evaluation of Contact Lens Care Regimens in Removing Tear Lipids on Silicone Hydrogel Lens (콘택트렌즈 관리방법에 의한 실리콘하이드로겔렌즈의 지방침전물 제거효과)

  • Kang, You-Sun;Lee, Koon-Ja;Ju, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2010
  • Purpose: An in vitro study was conducted to compare the lipid cleaning efficacy of care solutions on balafilcon A silicone hydrogel (SiHy) lens. Methods: Lipid spoilation was performed by incubating balafilcon A SiHy lenses in phosphate buffered saline (PBS) containing oleic acid, oleic acid methyl ester and cholesterol. Spoiled contact lenses rinsed with PBS were cleaned with surfactant cleaner, alcohol containing cleaner and multipurpose solution (MPS) respectively and repetitive spoilation and cleaning was conducted up to 14 times. To observe the cleaning effect of ultrasonic wave on the lipid deposit, each spoiled lens was ultrasonicated and then compared with non-sonicated lens. Lipids deposit on the contact lenses was extracted by methanol:chloroform (1:1, v/v) solution. High performance liquid chromatography was used to analyze and quantify lipid deposit extracts. Results: The effectiveness of alcohol containing surfactant cleaner on the lipid deposits was better than that of surfactant cleaner and MPS, and the cleaning efficacy was significantly higher in the ultrasonic wave treated group. Lipid deposits were not removed completely by contact lens care solutions so that lipid deposits increased continuously and cumulatively. Conclusions: The cleaning efficacy of contact lens care solutions was not satisfactory to remove lipid deposits on the SiHy lens that new cleaning products specially designed for SiHy lenses are needed to develop.

Vibration Analysis and Design of Ultrasonic Horn to the Bonded Dissimilar Materials (이종접합을 위한 초음파 혼 설계 및 진동해석)

  • Jung, An-Mok;Jeon, Euy-Sik;Kim, Chul-Ho
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.79-79
    • /
    • 2009
  • Ultrasonic fine welding, cutting, cleaning, inspection and measurement is widely used in various fields over 20kHz. However, for High Frequency of 60kHz or more study areas is still insufficient, and the result is lacking. Therefore, this study used ultrasonic horn to the Bonding of Dissimilar Materials for effective design. Finite element analysis (FEA) is using the equations of motion to establish the model. The optimal design for the basic interpretation of vibration characteristics of the ultrasonic measures horn will examine the design.

  • PDF

Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning (Ir-192 밀봉선원의 표면오염 방지)

  • Kuk, Il Hiun;Park, Chun Deuk;Koo, Ja Ho
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

A Study on Optimization of Megasonic Cleaning Process for Manufacturing LCD

  • Kim, Young-Sook;Kim, Hie-Sik;Park, Gi-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.97.4-97
    • /
    • 2001
  • Recently, TFT LCD (thin film transistor liquid crystal display) manufacturing industry is more concerned with the ways of cleaning large TFT LCD´s with high pixed density than ever Ultrasonic cleaners with high frequencies like 1MHz (megasonic cleaners) are effective in removing very small particles without causing mechanical damage to the surface. In this study a megasonic cleaner for TFT LCD manufacturing process is developed and the performance is evaluated through experiments. The experimental results show that the developed magasonic cleaners is effective in removing very small particle from the LCD panel.

  • PDF

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.