• Title/Summary/Keyword: ultrafiltration membrane

Search Result 476, Processing Time 0.023 seconds

Effect of coagulation conditions on ultrafiltration for wastewater effluent

  • Maeng, Sung Kyu;Timmes, Thomas C.;Kim, Hyun-Chul
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.185-199
    • /
    • 2017
  • Low-pressure membrane filtration is increasingly used for tertiary treatment of wastewater effluent organic matter (EfOM), mainly comprising organic base/neutral compounds. In-line coagulation with underdosing, charge neutralization, and sweep floc conditions prior to ultrafiltration (UF) was studied to determine removals of the EfOM components and consequent reduction of fouling using polyethersulfone membranes. Coagulation and UF substantially reduced fouling for all coagulation conditions while removing from 7 to 38% of EfOM organic acids. From 7 to 16% of EfOM organic base/neutrals were removed at neutral pH but there was no significant removal for slightly acid coagulation conditions even though fouling was substantially reduced. Sweep floc produced the lowest resistance to filtration but may be inappropriate for in-line use due to the large added volume of solids. Charge-neutralization resulted in poor recovery of the initial flux with hydraulic cleaning. Under-dosing paralleled sweep floc in reducing hydraulic resistance to filtration (for sub-critical flux) and the initial flux was also easily recovered with hydraulic cleaning. Hydrophobic and hydrophilic base/neutrals were identified on the fouled membranes but as previously reported the extent of fouling was not correlated with accumulation of organic base/neutrals.

Fabrication of Boehmite-based UF Ceramic Membrane (베마이트를 이용한 UF 세라믹 분리막의 제조)

  • Wi, In-Hee;Shin, Dong-Wook;Han, Kyu-Sung;Kim, Jin-Ho;Cho, Woo-Seok;Hwang, Kwang-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.337-343
    • /
    • 2014
  • A single layer ultrafiltration(UF) ceramic membrane was prepared using boehmite sol. Boehmite was synthesized using a typical sol-gel process with optimization of the viscosity, pH, molar ratio of aluminum isopropoxide(AIP) and $HNO_3$. Boehmite sol was coated on a microfiltration(MF) support using the dip-coating method. MF support was dipped into the boehmite sol with a withdrawal speed of 5 mm/s and was maintained for 10 s in the boehmite sol, resulting in a uniform UF membrane layer of $10{\mu}m$ thickness. The porosity of the obtained membrane was measured and found to be 41.2%; the pore size was found to range from 80~100 nm, corresponding to the pore size of the UF membrane. The flux of the obtained membrane was initially 540 $L/m^2h$ and approximately 85% of the initial flux was recovered using a periodic back-flushing process.

Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -I. Permeation Characteristics of Polysulfone Flat Plate Membrane- (Si 입자를 함유한 반도체 세정폐수의 한외여과 특성[I] -Polysulfone 평판막에 의한 투과분리-)

  • 곽순철;이석기;전재홍;남석태;최호상
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 1998
  • Permeation behavior of the semiconductor rinsing wastewater containing Si particles was examined by ultrafiltration using the polysulfone plate membrane. The permeation flux was gradually decreased with time. It was due to the growth of cake deposited on the membrane surface and the pore plugging by Si particles. Permeation flux of cross flow type was 1.4 times higher than that of the dead end flow type. Nitrogen back flushing which is the removing method of membrane fouling was superior to the water sweeping. With nitrogen back flushing, the decrease of permeation flux due to the fouling was recovered about 85 % to the initial flux in the flat plate membrane system. The rejection rate of Si particles was about 90 % and the size of Si particle in the permeate was about 70 nm.

  • PDF

Effects of Surface Modification of the Membrane in the Ultrafiltration of Waste Water

  • Cho Dong Lyun;Kim Sung-Hyun;Huh Yang Il;Kim Doman;Cho Sung Yong;Kim Byung-Hoon
    • Macromolecular Research
    • /
    • v.12 no.6
    • /
    • pp.553-558
    • /
    • 2004
  • An ultrafiltration membrane (polyethersulfone, PM 10) was surface-modified by treating it with low-tem­perature plasmas of oxygen, acrylic acid (AA), acetylene, diaminocyolohexane (DACH), and hexamethyldisiloxane (HMDSO). The effects that these modifications have on the filtration efficiency of a membrane in waste water treat­ment were investigated. The oxygen, AA, and DACH plasma-treated membranes became more hydrophilic. The water contact angles ranged from < $10^{\circ}\;to\;55^{\circ}$ depending on the type of plasma and the treatment conditions. The oxygen plasma-treated membranes displayed a higher initial flux $(312-429\%),$ but lower rejection $(6-91\%),$ than did an untreated membrane. The AA plasma-treated membranes displayed lower or higher initial flux $(42-156\%),$ depending upon the treatment conditions, but higher rejection $(224-295\%)$ in all cases. The DACH plasma-treated membranes displayed lower initial flux. All of them, especially the AA plasma-treated membrane, displayed improved fouling resistance with either a slower or no flux decline. Acetylene and HMDSO plasma-treated membranes became more hydrophobic and displayed both lower initial flux and lower fouling resistance.

Application in Ultrafiltration and Reverse Osmosis Module Set with Acrylic Wastewater Pretreated by Coagulation-Filtration-Neutralization Process (응집-여과-중화 공정에 의해 전처리된 아크릴 폐수의 한외여과와 역삼투 모듈 조합 공정에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with coagulation-filtration-neutralization, it was utilized in UF/RO process. After composing of ultrafiltration and reverse osmosis module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. It was found that permeate flux of UF module in module set 4 was about two${\sim}$three times larger than that of UF module in module set 1. Final quantity of permeate from the module set 2 and module set 3 combined with tubular module was shown very good result. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in all UF modules. The removal efficiency of TDS, T-N and COD was very excellent in RO module. Final water quality of acrylic wastewater was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Synthesis of Sulfonated Polyethersulfone Membrane Material for Ultrafiltration by Heterogeneous Sulfonation and Fouling Reduction Effect (불균일계 술폰화에 의한 한외여과용 폴리에테르 술폰 막소재 합성과 fouling 감소효과)

  • 김인철;최중구;최남석;김종호;탁태문
    • Membrane Journal
    • /
    • v.8 no.4
    • /
    • pp.210-219
    • /
    • 1998
  • Sulfonated poly(ether sulfone)(SPES) of various ion exchange capacity (IEC) was prepared by heterogeneous sulfonation with chlorosulfonic acid (CSA) to make hydrophilic ultrafiltration membrane for reducing fouling. The effects of CSA concentration, reaction temperature and reaction time has been investigated. The reaction was effective when the temperature is above 10$\circ$C and the CSA concentration is over 0.05 mol, although polymer chain has been significantly degraded. The substitution of sulfonic acid groups was characterized by FTIR and $^1$H-NMR. Transport properties and fouling test have been conducted to the modified SPES ultrafiltration rnembranrs by heterogeneors method. Membranes were obtained using DCM and PVP as a non-solvent and pore forming agent, respectively. Flux reduced and rejection increased with ion exchange capacity. Finger-like structure was disappeared and the thickness of top layer was increased. Dense membrane by non-solvent DCM and porous membrane by pore forming agent PVP was prepared. Fouling was reduced with increasing ion exchange capacity because of hydrophilicity.

  • PDF

Evaluation of Ultrafiltration Membrane Using Gel Permeation Chromatography (GPC를 이용한 한외여과막의 평가)

  • 정건용;정동진;김천호;신현수;민병렬;김래현
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.81-87
    • /
    • 2003
  • The permeation experiments f3r the aqueous dextran solutions of which the molecular weights were distributed between several thousands and million daltons were carried out using the dead-end cell system equipped with sheet membrane to determine the molecular weight cut-off (MWCO) of ultrafiltration membranes. The dextran rejections with respect to molecular weight were obtained by GPC analysis of feed and permeate solutions, then the MWCO was decided as the dextran molecular weight corresponding to the 90% rejection. The MWCO of PBTK membrane manufactured by Millipore was varied between 63,000 and 68,000 daltons as the pressure increased from 0.5 to 2.0 bar. However, the MWCO of PBQK(Millipore) and UE 1812(Saehan) under the above operating pressure increased to 3.5 and 4.3 times, respectively. Also, the MWCO of PBTK increased to 25% as the membrane permeation increased from 10 to 40% of the feed solution.

Simultaneous removal of nitrate and phosphate by micellar-enhanced ultrafiltration(MEUF) using PENTANOX 4X

  • 양지원;김보경;백기태;김호정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.447-450
    • /
    • 2003
  • The feasibility of PENTANOX 4X for the simultaneous removal of nitrate and phosphate was investigated using micellar-enhanced ultrafiltration. Because PENTANOX 4X has cationic property at low pH, anionic contaminants can be bound to PENTANOX 4X micelle by electrostatic interaction. At pH 3, 90% of nitrate and 72% of phosphate were removed by 27 mM of PENTANOX 4X, which were equivalent to 20 mM of CPC. PENTANOX 4X of > 80 % was rejected by ultrafiltration membrane and did not make any counter-ion such as chloride for CPC which might cause second-pollution.

  • PDF

A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes (활성탄과 Membrane을 이용한 수처리효과에 관한연구)

  • 김영진;김영규;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF