• Title/Summary/Keyword: ultra-filtration

Search Result 72, Processing Time 0.025 seconds

Pretreatment and Rapid Detection Methods for Wastewater-Based Epidemiology (하수역학 구축을 위한 시료 전처리 기술과 신속검출기술)

  • Lee Jai-Yeop;Lee Bokjin;Jesmin Akter;Ahn Chang Hyuk;Kim Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.1
    • /
    • pp.102-110
    • /
    • 2023
  • Wastewater Based Epidemiology (WBE) provides useful information not only on the use of illegal drugs in the community, but also on the presence of hygiene and health products and infectious pathogens in sewage facilities. As a consequence of the SARS-CoV-19 virus epidemic in 2019, monitoring the status of the infection is of utmost importance. SARS-CoV-19 was also detected in sewage, and the number and trend of infections in the community suggest that the application of the WBE system would be useful and appropriate. This study introduces a pre-treatment concentration method including viruses in sewage samples. A total of seven methods which were subdivided into methods for adsorption-extraction, ultra-filtration, PEG precipitation, and ultra-centrifugation, and the results for analyzing the recovery rates were included. Meanwhile, it is necessary to pay attention to rapid detection technologies which analyze infectious pathogens at the site of sewage facilities. These can include ELISA, FTIR, SERS, and biosensor based on the detection principle, and the characteristics, advantages, and disadvantages of each were summarized herein. If rapid detection technologies and accurate quantitative analyses are further developed, the use of sewage mechanics in response to pandemic viruses is expected to expand further.

Flux Decline and Fouling Mechanism of Si Colloidal Solution During the Ultra-Filtration (환외여과에 있어서 Si 콜로이드 용액의 투과유속 감소 및 오염특성)

  • Nam, Suk-Tae;Jeon, Jae-Hong;Lee, Seok-Ki;Choi, Ho-Sang
    • Clean Technology
    • /
    • v.5 no.2
    • /
    • pp.25-35
    • /
    • 1999
  • Behavior of permeate flux decline was examined through the hollow fiber membrane in ultrafiltration system for Si colloidal solution. Flux decline with time was due to the growth of Si cake deposited on the membrane surface and the pore blocking by Si particles for the hollow fiber membrane. At the pseudo steady state of operation, the permeate flux of dead-end flow was 60 % to that of the cross flow. The ratio of permeate flux to the pure water flux, $J/J_w$, decreased with increasing the trans-membrane pressure, from 64.2 % for $0.5kg_f/cm^2$ to 45.7 % for $2.0kg_f/cm^2$. When the feed flow rate was 3 L/min, the pore blocking model was dominant at the initial period of filtration and was followed by the cake filtration model. And with increasing the feed flow rate from 1 L/min to 3 L/min, $R_c$ was $1.79{\times}10^{12}{\sim}2.34{\times}10^{12}m^{-1}$ which was the about 40 % decreased value to that of the 1 L/min while $R_p$ was not changed and was $1.71{\times}10^{12}m^{-1}$ approximately.

  • PDF

Analysis of Membrane Integrity and Removal Efficiency Considering Membrane Defect and Pore Size (막 파단 및 공극크기에 따른 막 완결성 및 제거효율 분석)

  • Hur, Hyun-chul;Rhee, Ok-jae;Lee, Kwang-jae;Kim, Kwang-ho;Choi, Young-june;Lee, Joo-hee;Hong, Seungkwan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Microfiltration (MF) and ultrafiltration (UF) processes for removal of particulate materials (i.e., turbidity, microorganisms and viruses) have been used to produce drinking water with higher quality. As membrane filtration technique has become widely applied for drinking water treatment, the importance of membrane integrity test (MIT) has also been increasingly emphasized. The results of pressure decay test (PDT) were presented in the paper to monitor membrane integrity. In this paper the PDT was carried out with deliberately-defected membrane fibers to evaluate the sensitivity of PDT on membrane fiber damage. Variation of pressure decay rate and removal rate were investigated to evaluate the impact of defection (defection ratio) and pore size of membrane. The membrane integrity could be successfully monitored by the PDT. The pressure decay rate varied from $0.002{\sim}0.189kg_f/cm^2hr$ with the initial pressure ranged from 0.2 to $1.0kg_f/cm^2hr$. Higher initial pressure which provided with higher pressure decay rate was preferred to evaluate the defection of membrane fiber. As for the particle removal rate, the Log Removal Rate (LRV) of kaolin solution decreased significantly from 3.78 to 2.31 when one fiber out of 3,200 fibers was cut. The membranes with different pore size were tested to evaluate virus removal efficiency. The virus removal rate of the MF membrane ($0.1{\mu}m$) was about 30% although the poliovirus was smaller than the pore size of the MF membrane, indicating that the removal rate was much lower than Korea Water Works Association (KWWA) certificate LRV of 1.5.

Preparation of Yeast Hydrolysate Enriched in Cyclo-His-Pro (CHP) by Enzymatic Hydrolysis and Evaluation of Its Functionality

  • Lee, Hyun Jung;Son, Heung Soo;Park, Chung;Suh, Hyung Joo
    • Preventive Nutrition and Food Science
    • /
    • v.20 no.4
    • /
    • pp.284-291
    • /
    • 2015
  • In this study, we attempted to enrich cyclo-His-Pro (CHP) using enzymatic hydrolysis of yeast and to evaluate the functionality of yeast hydrolysate (YH)-enriched CHP. Flavourzyme offered a better performance in enhancing CHP content than other proteases. The CHP enrichment conditions were optimized as follows: addition of 1% Flavourzyme, 48-h incubation at 60oC, and pH 6.0. The CHP content significantly increased by 20-fold after ultra-filtration (UF). Maximal CHP translation was obtained after heating for 8 h at 50oC and pH 7.0. YH showed poor foaming capacity between pH 3.0 to 9.0. The emulsifying activities of YHs were slightly higher at near acidic pH. Increase in heating temperature and time resulted in decreased CHP content. The results indicate that YH is more heat stable after UF. Therefore, the CHP in YH after UF can be used as a food additive with physiological CHP activity and high heat stability.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Antioxidant Effects of Carnosine Extracted from the Eel Anguilla japonica (뱀장어 Anguilla japonica 추출 Carnosine의 항산화 효과)

  • Lee, Keun-Tae;Song, Ho-Su;Park, Seong-Min
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.4
    • /
    • pp.193-200
    • /
    • 2007
  • Ion-exchange chromatography and ultra-filtration permeation were used to extract carnosine from the eel Anguilla japonica. In an investigation of its antioxidant properties, the eel carnosine prevented lipid peroxidation in linoleic acid systems, scavenged free radicals, and exhibited superoxide dismutase-like activity. These activities increased as the carnosine concentration increased. The nitrite scavenging effects (NSEs) of commercial carnosine and the eel carnosine were measured at various acidic pHs (1.2, 3.0, and 4.2). For both types of carnosine, the maximum NSE was observed at pH 1.2. At this pH, the NSE of the eel carnosine was 65.3%. Both types of carnosine were effective at maintaining reasonably good color of ground beef patties over 5 days of storage at $4^{\circ}C$ and inhibited metmyoglobin formation as well as lipid peroxidation. These data suggest that the eel carnosine might be useful as a "natural" antioxidant in commercial production and storage of muscle foodstuffs.

Development of the ultra/nano filtration system for textile industry wastewater treatment

  • Rashidi, Hamidreza;Sulaiman, Nik Meriam Nik;Hashim, Nur Awanis;Bradford, Lori;Asgharnejad, Hashem;Larijani, Maryam Madani
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.333-344
    • /
    • 2020
  • Advances in industrial development and waste management over several decades have reduced many of the impacts that previously affected ecosystems, however, there are still processes which discharge hazardous materials into environments. Among industries that produce industrial wastewaters, textile manufacturing processes play a noticeable role. This study was conducted to test a novel continuous combined commercial membrane treatment using polyvinylidene fluoride (PVDF), ultrafiltration (UF), and polyamide (PA) nanofiltration (NF) membranes for textile wastewater treatment. The synthetic textile wastewater used in this study contained sodium silicate, wax, and five various reactive dyes. The results indicate that the removal efficiency for physical particles (wax and resin) was 95% through the UF membrane under optimum conditions. Applying UF and NF hybrid treatment resulted in total effective removal of dye from all synthetic samples. The efficiency of sodium silicate removal was measured to be between 2.5 to 4.5% and 13 to 16% for UF and NF, respectively. The chemical oxygen demand in all samples was reduced by more than 85% after treatment by NF.

Fabrication of Field Emitter Arrays by Transferring Filtered Carbon Nanotubes onto Conducting Substrates

  • Jang, Eun-Soo;Goak, Jung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.311-311
    • /
    • 2009
  • Carbon nanotubes (CNTs) belong to an ideal material for field emitters because of their superior electrical, mechanical, and chemical properties together with unique geometric features. Several applications of CNTs to field emitters have been demonstrated in electron emission devices such as field emission display (FED), backlight unit (BLU), X-ray source, etc. In this study, we fabricated a CNT cathode by using filtration processes. First, an aqueous CNT solution was prepared by ultrasonically dispersing purified single-walled CNTs (SWCNTs) in deionized water with sodium dodecyl sulfate (SDS). The aqueous CNT solution in a milliliter or even several tens of micro-litters was filtered by an alumina membrane through the vacuum filtration, and an ultra-thin CNT film was formed onto the alumina membrane. Thereafter, the alumina membrane was solvated by acetone, and the floating CNT film was easily transferred to indium-tin-oxide (ITO) glass substrate in an area defined as 1 cm with a film mask. The CNT film was subjected to an activation process with an adhesive roller, erecting the CNTs up to serve as electron emitters. In order to measure their luminance characteristics, an ITO-coated glass substrate having phosphor was employed as an anode plate. Our field emitter array (FEA) was fairly transparent unlike conventional FEAs, which enabled light to emit not only through the anode frontside but also through the cathode backside, where luminace on the cathode backside was higher than that on the anode frontside. Futhermore, we added a reflecting metal layer to cathode or anode side to enhance the luminance of light passing through the other side. In one case, the metal layer was formed onto the bottom face of the cathode substrate and reflected the light back so that light passed only through the anode substrate. In the other case, the reflecting layer coated on the anode substrate made all light go only through the cathode substrate. Among the two cases, the latter showed higher luminance than the former. This study will discuss the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the either side.

  • PDF

Luminous Characteristics of Transparent Field Emitters Produced by Using Ultra-thin Films of Single Walled Carbon Nanotubes

  • Jang, Eun-Soo;Goak, Jeung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • Carbon nanotubes (CNTs) are attractive material because of their superior electrical, mechanical, and chemical properties. Furthermore, their geometric features such as a large aspect ratio and a small radius of curvature at tip make them ideal for low-voltage field emission devices including backlight units of liquid crystal display, lighting lamps, X-ray source, microwave amplifiers, electron microscopes, etc. In field emission devices for display applications, the phosphor anode is positioned against the CNT emitters. In most case, light generated from the phosphor by electron bombardment passes through the anode front plate to reach observers. However, light is produced in a narrow depth of the surface of the phosphor layer because phosphor particles are big as much as several micrometers, which means that it is necessary to transmit through the phosphor layer. Hence, a drop of light intensity is unavoidable during this process. In this study, we fabricated a transparent cathode back plate by depositing an ultra-thin film of single walled CNTs (SWCNTs) on an indium tin oxide (ITO)-coated glass substrate. Two types of phosphor anode plates were employed to our transparent cathode back plate: One is an ITO glass substrate with a phosphor layer and the other is a Cr-coated glass substrate with phosphor layer. For the former case, light was radiated from both the front and the back sides, where luminance on the back was ~30% higher than that on the front in our experiments. For the other case, however, light was emitted only from the cathode back side as the Cr layer on the anode glass rolled as a reflecting mirror, improving the light luminance as much as ~60% compared with that on the front of one. This study seems to be discussed about the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the cathode back side. The experimental procedures are as follows. First, a CNT aqueous solution was prepared by ultrasonically dispersing purified SWCNTs in deionized water with sodium dodecyl sulfate (SDS). A milliliter or even several tens of micro-liters of CNT solution was deposited onto a porous alumina membrane through vacuum filtration. Thereafter, the alumina membrane was solvated with the 3 M NaOH solution and the floating CNT film was easily transferred to an ITO glass substrate. It is required for CNT film to make standing CNTs up to serve as electron emitter through an adhesive roller activation.

  • PDF