• 제목/요약/키워드: ultimate shear

검색결과 706건 처리시간 0.041초

Experimental and analytical study on prestressed concrete hollow slabs with asymmetric boundary conditions

  • Ma, Haiying;Lai, Minghui;Xia, Ye
    • Structural Engineering and Mechanics
    • /
    • 제81권1호
    • /
    • pp.59-68
    • /
    • 2022
  • Prestressed prefabricated hollow core concrete slabs with spans of 5 m and 10 m are commonly used since last century and still in service due to the advantage of construction convenience and durability. However, the end slabs are regularly subjected to cracks at the top and fail with brittleness due to the asymmetric boundary conditions. To better maintain such widely used type of hollow core slabs, the effect of asymmetric constraint in the end slabs are systematically studied through detailed nonlinear finite element analyses and experimental data. Experimental tests of slabs with four prestressed tendons and seven prestressed tendons with different boundary conditions were conducted. Results observe three failure modes of the slabs: the bending failure mode, shear and torsion failure mode, and transverse failure mode. Detailed nonlinear finite element models are developed to well match the failure modes and to reveal potential damage scenarios with asymmetric boundary conditions. Recommendations regarding ultimate capacity of the slabs with asymmetric boundary conditions are made to ensure a safe and rational design of prestressed concrete hollow slabs for short span bridges.

Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구 (A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap)

  • 조병완;김철환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.137-147
    • /
    • 2012
  • 무철근 교량 바닥판은 콘크리트 내부의 철근을 없애고 거더를 Strap으로 횡구속시켜 Arching action을 극대화시킨 교량 바닥판이다. 본 연구에서는 무철근 바닥판의 균열제어를 목적으로 FRP bar의 배치량을 변수로 하여 내하력과 균열, 연성도, 파괴시 응력수준 등을 판단하여 FRP bar 최소 배치량을 제시하였다. 실험결과 Steel strap 무철근 바닥판은 최소 0.15% FRP 보강근만 배치하여도 내하력과 연성이 확연히 향상됨을 확인하였다. FRP bar를 보강한 무철근 바닥판에 대하여 피로실험을 수행하였으며 200만회 반복하중 재하후 균열, 잔류 처짐 등에서 장기 사용성에 문제가 없음을 확인하였다. 교량 바닥판은 대체로 펀칭전단 파괴를 하며 2방향 슬래브의 전단강도식을 적용할 수 있으나 ACI, AASHTO 등에서는 바닥판의 비선형 파괴형상과 횡구속에 의한 Arching 효과를 명확히 고려하지 못하기 때문에 실제 파괴강도보다 과소평가 한다. 본 연구에서는 Steel strap 바닥판의 실제 파괴형상과 Strap에 의한 횡구속도를 고려한 펀칭전단강도식을 제안하였으며 이는 실험결과와도 비교적 잘 일치하는 결과를 보여주었다.

FRP로 보강한 비보강 조적 벽체의 전단강도 산정 (Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet)

  • 배백일;윤효진;최창식;최현기
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.305-313
    • /
    • 2012
  • 비보강 조적조 건축물은 전세계적으로 기존의 건물 및 역사 건축물의 많은 부분을 차지하고 있다. 특히, 최근 지진이 전세계적으로 빈번하게 나타남에 따라 비보강 조적조 구조물에 대한 내진 보강 대책이 요구되고 있다. 현재 비보강 조적조의 보강방법으로는 숏크리트, ECC jacketing, FRPs(fiber reinforced polymer sheet) 등이 개발되어 사용되고 있다. 특히 많은 엔지니어들이 FRPs를 사용한 보강방법을 채택하는 경향이 보이는데 이는 숏크리트나 ECC jacketing과는 달리 벽체의 두께 확장에 따른 구조물 자중 증가 문제없이 비보강 조적조의 전단강도를 향상시킬 수 있기 때문이다. 그러나 비보강 조적 벽체의 복잡한 역학적 거동과 FRPs를 사용한 실험 데이터의 부족은 아직까지도 적절한 보강량을 산정하는데 어려움을 주고 있다. 이 연구는 비보강 조적조의 면내 거동을 확인하고 두 가지의 다른 특징을 가진 FRPs를 사용한 보강 효과에 대한 정보를 주기 위해 수행되었다. 실험체는 1970년대 한국에서 빈번하게 지어진 저층형 연립주택의 내벽을 대상으로 하고 있으며 별도의 내진 설계는 되어있지 않은 상태이다. 실험체의 형상비는 실제 상황을 반영하기 위해 1에 가깝게 설정되어 있다. 보강 재료로는 탄소섬유보강 시트와 하이브리드 시트를 사용하였으며 이들은 각각 다른 극한 강도와 탄성계수 및 극한 변형률을 보유하고 있다. 연구 결과 비보강 조적 벽체의 면내 전단력 저항 성능을 확인하였으며 FRPs가 사용된 내진 보강 방안의 특성을 분석할 수 있었다. 또한 FRPs를 사용한 보의 전단보강 방법에 착안하여 비보강 조적조에 대한 FRPs의 보강 설계안을 도출할 수 있었다.

Hysteretic characteristics of steel plate shear walls: Effects of openings

  • Ali, Mustafa M.;Osman, S.A.;Yatim, M.Y.M.;A.W., Al Zand
    • Structural Engineering and Mechanics
    • /
    • 제76권6호
    • /
    • pp.687-708
    • /
    • 2020
  • Openings in steel plate shear walls (SPSWs) are usually used for decorative designs, crossing locations of multiple utilities and/or structural objectives. However, earlier studies showed that generating an opening in an SPSW has a negative effect on the cyclic performance of the SPSW. Therefore, this study proposes tripling or doubling the steel-sheet-plate (SSP) layer and stiffening the opening of the SPSW to provide a solution to undesirable opening effects, improve the SPSW performance and provide the infill option of potential strengthening measures after the construction stage. The study aims to investigate the impact of SSP doubling with a stiffened opening on the cyclic behaviour, expand the essential data required by structural designers and quantify the SPSW performance factors. Validated numerical models were adopted to identify the influence of the chosen parameters on the cyclic capacity, energy dissipation, ductility, seismic performance factors (SPF) and stiffness of the suggested method. A finite Element (FE) analysis was performed via Abaqus/CAE software on half-scale single-story models of SPSWs exposed to cyclic loading. The key parameters included the number of SSP layers, the opening size ratios corresponding to the net width of the SSP, and the opening shape. The findings showed that the proposed assembly method found a negligible influence in the shear capacity with opening sizes of 10, 15, 20%. However, a deterioration in the wall strength was observed for openings with sizes of 25% and 30%. The circular opening is preferable compared with the square opening. Moreover, for all the models, the average value of the obtained ductility did not show substantial changes and the ultimate shear resistance was achieved after reaching a drift ratio of 4.36%. Additionally, the equivalent sectional area of the SSP in the twin and triple configuration of the SPSWs demonstrated approximately similar results. Compared with the single SSP layer, the proposed configuration of the twin SSP layer with a stiffened opening suggest to more sufficiency create SSP openings in the SPSW compared to that of other configurations. Finally, a tabular SPF quantification is exhibited for SPSWs with openings.

Recognition of damage pattern and evolution in CFRP cable with a novel bonding anchorage by acoustic emission

  • Wu, Jingyu;Lan, Chengming;Xian, Guijun;Li, Hui
    • Smart Structures and Systems
    • /
    • 제21권4호
    • /
    • pp.421-433
    • /
    • 2018
  • Carbon fiber reinforced polymer (CFRP) cable has good mechanical properties and corrosion resistance. However, the anchorage of CFRP cable is a big issue due to the anisotropic property of CFRP material. In this article, a high-efficient bonding anchorage with novel configuration is developed for CFRP cables. The acoustic emission (AE) technique is employed to evaluate the performance of anchorage in the fatigue test and post-fatigue ultimate bearing capacity test. The obtained AE signals are analyzed by using a combination of unsupervised K-means clustering and supervised K-nearest neighbor classification (K-NN) for quantifying the performance of the anchorage and damage evolutions. An AE feature vector (including both frequency and energy characteristics of AE signal) for clustering analysis is proposed and the under-sampling approaches are employed to regress the influence of the imbalanced classes distribution in AE dataset for improving clustering quality. The results indicate that four classes exist in AE dataset, which correspond to the shear deformation of potting compound, matrix cracking, fiber-matrix debonding and fiber fracture in CFRP bars. The AE intensity released by the deformation of potting compound is very slight during the whole loading process and no obvious premature damage observed in CFRP bars aroused by anchorage effect at relative low stress level, indicating the anchorage configuration in this study is reliable.

고강도 폴리머 콘크리트 휨부재의 응력블럭 (Stress Block of High Strength Polymer Concrete Flexural Members)

  • 김관호;김남길;연규석
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.638-644
    • /
    • 2002
  • 본 연구에서는 압축강도 1400 kgf/$\textrm{cm}^2$ 를 갖는 불포화 폴리에스터 폴리머 콘크리트를 이용하여 제작한 C형 시험체에 대한 편심압축 시험을 통하여 폴리머 콘크리트 휨부재의 응력-변형률 관계를 구명하고 등가직사각형 응력블럭의 파라미터 $\alpha$, $\beta$1, ${\gamma}$를 산출하였다. 아울러 인장철근비를 달리하는 5종의 전단스팬비 4.0인 철근 보강 폴리머 콘크리트 보에 대한 휨시험에서 얻어진 극한모멘트 시험값과 C형 시험체 응력-변형률 곡선에서 산출되는 파라미터 $\alpha$=0.61, $\beta$1=0.73 를 이용하여 계산된 이론적인 극한모멘트 값을 비교하여 보았던 바, 인장철근비가 0.50 $\rho$b 이상일때 시험값과 이론값이 비교적 잘 부합됨을 확인 할 수 있었다. 그러나 폴리머 콘크리트 휨 부재에 대한 보다 정확한 설계기준의 마련을 위해서는 압축강도와 크기를 변수로 하는 C형 시험체에 대한 보다 많은 시험을 통한 파라미터의 체계적인 연구가 필요하다.

철근(鐵筋)콘크리트 구조물(構造物)의 전단거동(剪斷擧動)에 관한 연구(研究) (A Study on the Shear Behavior of Reinforced Concrete Structures)

  • 장동일;곽계환
    • 대한토목학회논문집
    • /
    • 제7권1호
    • /
    • pp.83-92
    • /
    • 1987
  • 피로하중(疲勞荷重)을 받는 RC 구조물은 정하중(靜荷重)을 받는 경우에 비(比)하여 큰 변형율(變形率)과 미세균열(微細龜裂)을 수반하게 된다. 계속되는 반복하중(反復荷重)으로 인하여 균열(龜裂)은 진전(進展)하게 되고 이러한 균열부(龜裂部)의 응력집중(應力集中)은 스터럽과 인장철근(引張鐵筋)의 변형율(變形率)을 계속 증가(增加)시키게 되어 결과적(結果的)으로 RC 구조물은 파괴(破壞)단계에 이르게 된다. 스터럽의 변형율(變形率)은 사인장균열(斜引張龜裂)이 발생(發生)하면서 급격한 증가(增加)를 보이게 되며 이와 같은 스터럽의 평균변형율(平均變形率)은 반복회수(反復回數)(N)의 증가(增加)에 따라 logN에 비례함을 알 수 있었다. 이와 같이 RC 구조물의 파괴(破壞)는 콘크리트의 균열성장(龜裂成長)과 밀접한 관계가 있다. 또한, RC 구조물의 피로수명(疲勞壽命)을 100만(萬) cycle로서 볼 때 이에 대한 피로강도(疲勞强度)는 정적극한강도(靜的極限强度)의 약 60~70% 정도로 알려져 있다. 본(本) 실험(實驗)에서 사용(使用)된 RC 구조물의 피로강도(疲勞强度)는 약 70%로서 기존의 연구결과(硏究結果)와 잘 부합됨을 확인 할 수 있었다. 따라서 RC 구조물이 이보다 높은 피로하중(疲勞荷重)을 받게되면 피로수명(疲勞壽命)은 훨씬 짧아지게 되며, 이와 같이 피로하중(疲勞荷重)과 피로수명(疲勞壽命)과의 관계는 서로 반비례(反比例)함을 확인할 수 있었다.

  • PDF

Model tests on bearing capacity and accumulated settlement of a single pile in simulated soft rock under axial cyclic loading

  • Zhang, Benjiao;Mei, Can;Huang, Bin;Fu, Xudong;Luo, Gang;Lv, Bu
    • Geomechanics and Engineering
    • /
    • 제12권4호
    • /
    • pp.611-626
    • /
    • 2017
  • The research reported herein is concerned with the model testing of piles socketed in soft rock which was simulated by cement, plaster, sand, water and concrete hardening accelerator. Model tests on a single pile socketed in simulated soft rock under axial cyclic loading were conducted and the bearing capacity and accumulated deformation characteristics under different static, and cyclic loads were studied by using a device which combined oneself-designed test apparatus with a dynamic triaxial system. The accumulated deformation of the pile head, and the axial force, were measured by LVDT and strain gauges, respectively. Test results show that the static load ratio (SLR), cyclic load ratio (CLR), and the number of cycles affect the accumulated deformation, cyclic secant modulus of pile head, and ultimate bearing capacity. The accumulated deformation increases with increasing numbers of cycles, however, its rate of growth decreases and is asymptotic to zero. The cyclic secant modulus of pile head increases and then decreases with the growth in the number of cycles, and finally remains stable after 50 cycles. The ultimate bearing capacity of the pile is increased by about 30% because of the cyclic loading thereon, and the axial force is changed due to the applied cyclic shear stress. According to the test results, the development of accumulated settlement is analysed. Finally, an empirical formula for accumulated settlement, considering the effects of the number of cycles, the static load ratio, the cyclic load ratio and the uniaxial compressive strength, is proposed which can be used for feasibility studies or preliminary design of pile foundations on soft rock subjected to cyclic loading.

하이브리드 보강기법을 활용한 고강도 콘크리트 내민받침의 성능 향상 (Enhancing the Performance of High-Strength Concrete Corbels Using Hybrid Reinforcing Technique)

  • 양준모;이주하;민경환;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.13-16
    • /
    • 2008
  • 전단경간-깊이의 비가 1을 넘지 않는 캔틸레버로서 응력교란구역을 형성하는 내민받침은 보에 의해 전달되는 수직하중과 지지하고 있는 부재의 수축, 온도 변형, 크리프 변형에 의해 전달되는 수평 하중에 저항하는 부재이다. 최근, 고강도 콘크리트의 사용이 증가하고 있고, 철근 콘크리트 구조물의 부식에 대한 관심이 높아지면서 고성능의 보강재를 콘크리트 부재에 전략적으로 적용하는 하이브리드 보강기법에 대한 연구가 활발히 진행되고 있다. 이에 본 연구에서는 강섬유 및 헤디드 바를 활용한 하이브리드 보강 기법을 내민받침에 적용하고자 섬유보강 고강도 콘크리트 내민받침을 제작하고 구조실험을 실시하였다. 강섬유의 혼입, 강섬유 혼입률의 증가에 따라 고강도 콘크리트 내민받침의 내하력, 강성, 연성은 증가하는 것으로 나타났고, 최대 균열폭은 감소하였다. 또한, 횡방향 철근에 용접하여 주인장 타이 철근을 정착한 내민받침 보다 헤디드 바를 주인장 타이 철근으로 사용한 내민받침이 더 높은 내하력, 강성, 연성을 보였다.

  • PDF

한계상태 설계법을 이용한 고강도 콘크리트 세그먼트 라이닝 설계 (A high strength concrete segment lining design using the limit state design code)

  • 박인준;고성일;황창희;오명호;김영준
    • 한국터널지하공간학회 논문집
    • /
    • 제14권5호
    • /
    • pp.547-559
    • /
    • 2012
  • 국내의 콘크리트 구조설계는 허용응력 설계법(ASD) 및 극한강도 설계법(USD)을 사용하고 있다. 허용응력설계 및 극한강도설계법은 경제적인 설계에 제한이 따르기 때문에 최근에 지하구조물의 설계에 극한한계상태 설계법의 채택을 다각적으로 검토하고 있는 상황이다. 이를 뒷받침하고자 본 연구에서는 일본 한계상태 설계법(LSD)에 의거한 국내 고강도 콘크리트 라이닝에 대한 발생 단면력을 산정하였으며, 이를 국내의 극한강도 설계법과 비교함으로서 경제적 설계결과 도출 가능성 및 국내 적용성을 분석하고자 하였다. 해석결과, 철근량 산정과 밀접한 관계가 있는 최대 모멘트 발생양상은 두 설계법 모두 유사하나, 발생 부재력은 일본 한계상태 설계법이 극한강도 설계법에 비하여 모멘트는 26.0%, 전단력은 26.7%감소하는 것을 확인할 수 있었으며, 이를 통하여 안정성이 확보된 조건에서 경제적인 세그먼트 설계가 가능함을 확인하였다.