• Title/Summary/Keyword: ultimate displacement

Search Result 337, Processing Time 0.039 seconds

Estimation of Confinement Stress for Concrete Compressive Member Rehabilitated with Carbon Fiber Laminate (탄소섬유판으로 보강된 콘크리트 압축부재의 횡보강응력의 산정)

  • Lee, Hee-Kyoung;Kim, Sung-Chul;Yoo, Seong-Hoon;Kim, Joong-Koo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.593-600
    • /
    • 1998
  • In this study, confinement stress of concrete compression members rehabilitated with C.F.L were analyzed from the test. Test parameters are spacing, thickness and ply of rehabilitation material. Displacement, failure load were measured during test. The failure mode and ultimate load were analyzed from these measured data. In this study, a model equation for calculation of the confining stress with C.F.L was proposed based on the test results investigated here. The proposed equation included the effects of spacing, thickness and ply of rehabilitation material.

  • PDF

Quasi-Static Test for Seismic Performance of Circular R.C. Bridge Piers Before and After Retrofitting (유리섬유 보강 원형 철근콘크리트 교각의 내진성능에 관한 준정적 실험연구)

  • 정영수;이강균;한기훈;이대형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.107-118
    • /
    • 1999
  • 10 RC bridge piers have been made on a 1/3.4 scale model, and six piers of them were retrofitted with glassfiber. The have been tested in the quasi-static cyclic load so as to investigate their seismic enhancement before and after retrofitting with glassfibers. The objective of this experimental study is to investigate how to strength the ductility of reinforced concrete bridge piers which have been nonseismically designed and constructed in Korea before 1992. Important test parameters are axial load, load pattern, retrofit type. Glassfiber sheets were used for retrofitting in the plastic hinge region of concrete piers. The nonlinear behavior of bridge columns have been evaluated through their yield and ultimate strength, energy dissipation, displacement ductility and load-deflection characteristics under quasi-static cyclic loads. It can be concluded from the test that concrete piers strengthened with glassfibers have been enhanced for their ductile behavior by approximate 50%.

Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles

  • Banovic, Ivan;Radnic, Jure;Grgic, Nikola
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.103-117
    • /
    • 2020
  • The effect of the foundation size on the efficiency of seismic base isolation using a layer of stone pebbles is experimentally investigated. Four scaled models of buildings with different stiffnesses (from very stiff to soft) were tested, each with the so-called small and large foundation, and exposed to four different accelerograms (different predominant periods and durations). Tests were conducted so that the strains in the model remained elastic and afterwards the models were tested until collapse. Each model was tested for the case of the foundation being supported on a rigid base and on an aseismic layer. Compared to the smaller foundation, the larger foundation results in a reduced rocking effect, higher earthquake forces and lower bearing capacity of the tested models, with respectable efficiency (reduced strain/stress, displacement and increase of the ultimate bearing capacity of the model) for the considered seismic base isolation compared to the foundation on a rigid base.

Analytical performance evaluation of modified inclined studs for steel plate concrete wall subjected to cyclic loads

  • Lim, Jin-Sun;Jeong, Young-Do;Nam, Jin-Won;Kim, Chun-Ho;Yi, Seong-Tae
    • Computers and Concrete
    • /
    • v.17 no.2
    • /
    • pp.227-240
    • /
    • 2016
  • An analytical study was conducted to investigate the effect of the shape and spacing of modified inclined studs used as shear connector between concrete and steel plate on the cyclic behavior of steel plate concrete (SC) shear wall. 9 different analysis cases were adopted to determine the optimized shape and spacing of stud. As the results, the skeleton curves were obtained from the load-displacement hysteresis curves, and the ultimate and yielding strengths were increased as the spacing of studs decrease. In addition, the strength of inclined studs is shown to be bigger compared to that of conventional studs. The damping ratios increased as the decrease of stiffness ratio. Finally, with decreasing the spacing distance of studs, the cumulative dissipated energy was increased and the seismic performance was improved.

Analytical fragility curves for typical Algerian reinforced concrete bridge piers

  • Kibboua, Abderrahmane;Naili, Mounir;Benouar, Djillali;Kehila, Fouad
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.411-425
    • /
    • 2011
  • This paper illustrates the results of a seismic vulnerability study aimed to derive the fragility curves for typical Algerian reinforced concrete bridge piers using an analytical approach. Fragility curves express the probability of exceeding a certain damage state for a given ground motion intensity (e.g., PGA). In this respect, a set of 41 worldwide accelerometer records from which, 21 Algerian strong motion records are included, have been used in a non-linear dynamic response analyses to assess the damage indices expressed in terms of the bridge displacement ductility, the ultimate ductility, the cyclic loading factor and the cumulative energy ductility. Combining the damage indices defined for 5 damage rank with the ground motion indices, the fragility curves for the bridge piers were derived assuming a lognormal distribution.

Study of Smart Bi-directional Pile Load Test by Model Test (모형시험을 통한 Smart 양방향말뚝 재하시험에 관한 연구)

  • Kim, Nak-Kyung;Kim, Ung-Jin;Joo, Yong-Sun;Kim, Sung-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1088-1093
    • /
    • 2010
  • The Smart bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of piles can be known by using two different end plates. The first step is to measure end bearing capacity with smaller end plate and the second step is similar to the conventional O-cell test. In this study, model test was performed to evaluate the smart bi-directional pile load test in sand. Vertical displacement of the model pile were messured at the axial loading condition.

  • PDF

Experimental Research for Seismic Performance of Circular Hollow R.C. Bridge Pier (원형중공 콘크리트 교각의 내진성능에 대한 실험적 연구)

  • 한기훈;이강균;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.671-676
    • /
    • 1999
  • Because of relatively heavy dead weight of concrete itself and unavoidable heat of massive concrete in bridge piers, circular hollow columns are widely used in Korean highway bridges. Since the occurrence of 1995 Kobe earthquake, there have been much concerns about seismic design for various infrastructures, inclusive of bridge structures. It is, however, understood that there are not much research works for nonlinear behavior of circular hollow columns subjected to earthquake motions. The ultimate of this experimental research is investigate nonlinear behavior of circular hollow reinforced concrete bridge piers under the quasi-static cyclic load, and then to enhance their ductility by strengthening the plastic hinge region with glassfiber sheets. It is concluded from quasi-static tests for 7 bridge piers that energy dissipation capacity and curvatures for a given displacement ductility factor $\{\mu}=frac{\Delta}{\Delta_y}$are about 20% higher for the seismically designed columns and about 70% higher for the retrofitted piers than the nonseismically designed columns in a conventional way.

  • PDF

Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors (ㄱ형 Perfobond 리브 전단연결재의 적용성 평가)

  • Lee, Heung-Su;Chung, Chul-Hun;Kim, Byung-Suk;Kang, Jae-Yoon;Sohn, You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

A discrete particle model for reinforced concrete fracture analysis

  • Azevedo, N. Monteiro;Lemos, J.V.;Almeida, J.R.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.3
    • /
    • pp.343-361
    • /
    • 2010
  • The Discrete Element Method adopting particles for the domain discretization has recently been adopted in fracture studies of non-homogeneous continuous media such as concrete and rock. A model is proposed in which the reinforcement is modelled by 1D rigid-spring discrete elements. The rigid bars interact with the rigid circular particles that simulate the concrete through contact interfaces. The DEM enhanced model with reinforcement capabilities is evaluated using three point bending and four point bending tests on reinforced concrete beams without stirrups. Under three point bending, the model is shown to reproduce the expected final crack pattern, the crack propagation and the load displacement diagram. Under four point bending, the model is shown to match the experimental ultimate load, the size effect and the crack propagation and localization.

Axial behavior of steel-jacketed concrete columns

  • Rupp, J.;Sezen, H.;Chaturvedi, S.
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.59-75
    • /
    • 2014
  • A new concrete confinement model is developed to predict the axial load versus displacement behavior of circular columns under concentric axial load. The new confinement model is proposed for concrete filled steel tube columns as well as circular reinforced concrete columns with steel tube jacketing. Existing confinement models were evaluated and improved using available experimental data from different sets of columns tested under similar loading conditions. The proposed model is based on commonly used confinement models with an emphasis on modifying the effective confining pressure coefficient utilizing the strength of the unconfined concrete and the steel tube, the length of the column, and the thickness of the steel tube. The proposed model predicts the ultimate axial strength and the corresponding strain with an acceptable degree of accuracy while also highlighting the importance of the manner in which the steel tube is used.