• Title/Summary/Keyword: u-Safety

Search Result 1,356, Processing Time 0.027 seconds

Risk Factors Related to Photo Couplers(P/C) for Signal Transmission by Electronic Devices (전자기기의 신호전송을 위한 Photo Couplers(P/C) 의 위험 요소 발굴)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.26-30
    • /
    • 2013
  • The purpose of this study is to find risk factors by analyzing the operation principle of a photo coupler (P/C) used to remove the noise of electronic devices and establish a base for the performance improvement of developed products. It was found from the P/C circuit analysis of normal products that they were equipped with an electrolytic condenser of $0.1{\mu}F$ to smooth system signals. Due to the epoxy resin packing the external part of the P/C, this study experienced a limit to visually examine the damage to it. It could be seen from the analysis of electric characteristics of the P/C that the forward voltage ($V_f$) and reverse current ($I_r$) were 1.3 V and 10 uA, respectively. In addition, it is required that the breakdown voltage (VCE) between the collector (C) and emitter (E) be maintained at less than 35 V. The and of the damaged product #1 were comparatively good. However, the measurement of was 100.0 uA. From this, it is thought that a short circuit occurred to the internal circuit. Moreover, from the fact that the of the damaged product #2 was open circuit and the measurement of was 0.0 uA, it is thought that the collector and emitter was separated or insulation resistance was significantly high. Furthermore, from the fact that the of the damaged product #3 was open circuit and the measurement of was 0.0 uA, it is thought that the space between the collector (C) and emitter (E) failed to meet the design standard or that they were separated. Therefore, it is thought that fabricating the P/C by increasing the reverse current 10 mA to 50 mA will prevent its malfunction.

The Lightweight and the Self-escape Function Development of the SRL (SRL의 경량화 및 자가탈출기능 개발)

  • Kim, Sang Tae;Kwon, Oh Heon;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.15-21
    • /
    • 2014
  • Many kinds of falling prevention systems with a safety block have been supplied in order to prevent falling accidents and acquire the long life and cost down for the maintenance. However, there are not the reliable and domestic the falling prevention system until now. Almost systems were imported from U.S.A, Japan, U.K and Germany. The structural safety of the imported safety block is satisfied sufficiently, but it has heavy weight due to the cover with the aluminum and thickness. Especially, the falling prevention system as the safety block is very expensive. It brings about flow the enormous money out of country. Furthermore it has a heavy weight when workers climbed the ladder with a falling prevention system and moved, many workers are not feeling themselves. Thus, the aim of this work is to develop a commercial self-escape SRL(Self Retracting Lifeline) with the safety block function that has a light weight and an advanced strength. The cost efficiency and convenience of the system and safety for workers also will be improved remarkably even though this system has a light weight. The results show that the maximum stress is obtained in each part by the lower more than yield strength and has sufficient safety in the developed new safety block.

Performance Evaluation Simulation of Electrical IT Equipment for U-city Safety (U-city 안전을 위한 전기IT기기의 성능평가 시뮬레이션)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.159-163
    • /
    • 2011
  • U-City의 안전을 위하여 안전한 전기공급과 전기안전 점검과 전송에 필요한 전기IT 인프라는 중대한 요소이다. U-City의 건설에 필요한 전기IT기기의 설계와 개발 및 제조를 하고 Test-bed에 설치하여 성능 평가를 한 후에 검증을 맡은 전기IT기기를 U-City 설치하여야 한다. 본 논문에서는 U-City 안전을 위한 전기IT기기에 대한 절연저항, 누설전류에 따르는 고온, 연기, Co2, 불꽃, 화재 등을 감지하는 센서를 부착하고, 발생할 수 있는 재난을 사전에 예방하기 위해 전기안전보호기술, 전기설비를 상시 감시할 수 있는 기반기술, 설비를 원격으로 관리할 수 있는 제품에 대한 성능평가와 시뮬레이션을 통해 U-City에 구축되려는 종합적인 전력통합감시시스템을 연구한다.

  • PDF

Design of U-IT Intelligent System for Monitoring the Safety of Metro Railway (도시철도 안전 관리를 위한 U-IT 지능형 시스템 설계)

  • Whang, Sung-Il;Park, Jung-Ho;Song, Jai-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1151-1152
    • /
    • 2008
  • Recently, ubiquitous sensor network forms the self-organization network, and transfers the information among sensor nodes that have computing technology ability. In this paper, we design and implement U-IT system for monitoring the safety of metro railway and underground shopping malls. For this, we implement sensor nodes to support IEEE 802.15.4 wireless communication standard using low power. Also we implement USN gateway node system to transmit the collected data from sensor nodes to database server over CDMA cellular network.

  • PDF

The Analysis on Establishment of National Consilience Complex in Korea (보건 및 의료분야 중심의 국가 복합과학기술타운조성 연구)

  • Kim, Jong-Kwon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.113-127
    • /
    • 2011
  • The information technology intensive society rapidly moves from manufacturing industry to information technology industry. This paradigm of Robot is depending on intelligent Robot instead of labor. The conventional Robot worked through environmental variation and shift of job. This Robot is unactively response to men's mandate. And, this Robot have had iterative jobs through manipulation of men. But, this intelligent Robot have new technology through society paradigm shift. The outstanding feature of this Robot is perception function and cognition, mobility and manipulation. The definition of original Robot means forceful and tedious, slavery job. This is from robota, robotnick of the Czech Republic. Karel Capek, a playwriter of the Czech Republic use of this letter at 'Rossum's Universal Robots. The service of U-Health is the fusion of Information Technology and Medical Service. The U-Health provides for doing about household's medical behavior. Conclusionally, the Chungbuk has merit on establishment of national consilience complex such as Medical Robot and U-Health.

  • PDF

A Study on Development of Dual-band RFID System (Dual-band RFID System 개발에 관한 연구)

  • Lee, Tae-Yun;Kim, Woong-Sub;Choi, Moon-Seung;Han, Woon-Soo;Jho, Yong-Chul;Kwon, Dae-Woo;Lee, Chang-Ho
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.645-648
    • /
    • 2009
  • 유비쿼터스 기술을 활용한 U-city와 같은 지역적인 서비스들이 다양한 분야에서 응용되고 있다. 유비쿼터스 기술 중 하나인 RFID는 사용하는 주파수에 따라 장 단점을 가지고 있기 때문에 단일 대역 주파수를 활용한 RFID 시스템은 다양해지는 사용자의 요구를 충족시키기에 명확한 한계를 가지고 있다. 따라서 연구를 통해 13.56MHz와 2.45GHz를 동시에 지원하는 Dual-Band RFID시스템을 개발하여 단일대역 RFID 서비스의 단점을 보완한다. 이를 위해 두 대역의 주파수를 지원하는 하드웨어와 소프트웨어를 개발하고, 능동형 태그의 배터리 수명에 관한 연구를 통해 보다 효율적으로 Dual-Band RFID 시스템을 구성한다.

  • PDF

Charging Characteristics of Electrostatic Sprayer Applied Square Pulse (구형파 펄스를 인가한 정전분무 장치의 대전량 특성)

  • 박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.573-578
    • /
    • 2003
  • In this study, new type of induction charging system for electrostatic spraying was manufactured and proposed to improve the electrical safety and charging efficiency. And parameters of proposed system to generate the maximum deposition current with electrical safety were selected and investigated. The selected parameters were frequency of square pulse and thickness of insulation material, outer diameter of device and thickness and positions of electrode. Charging quantity of water drop was measured by deposition current detected from sensing plate indirectly. The maximum deposition current for each parameter were 3.5[uA] at the frequency of 15[kHz] and thickness of 0.25[mm] insulating layer. And maximum deposition currents were 2.8[uA] and 3.0[uA] at 25[mm] outer diameter of charging device and 0.25[mm] thickness of electrode each. Effects of electrode position from spraying nozzle on deposition current was a little.