• Title/Summary/Keyword: u-Safety

Search Result 1,348, Processing Time 0.034 seconds

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.

Empirical Analysis on Bitcoin Price Change by Consumer, Industry and Macro-Economy Variables (비트코인 가격 변화에 관한 실증분석: 소비자, 산업, 그리고 거시변수를 중심으로)

  • Lee, Junsik;Kim, Keon-Woo;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.2
    • /
    • pp.195-220
    • /
    • 2018
  • In this study, we conducted an empirical analysis of the factors that affect the change of Bitcoin Closing Price. Previous studies have focused on the security of the block chain system, the economic ripple effects caused by the cryptocurrency, legal implications and the acceptance to consumer about cryptocurrency. In various area, cryptocurrency was studied and many researcher and people including government, regardless of country, try to utilize cryptocurrency and applicate to its technology. Despite of rapid and dramatic change of cryptocurrencies' price and growth of its effects, empirical study of the factors affecting the price change of cryptocurrency was lack. There were only a few limited studies, business reports and short working paper. Therefore, it is necessary to determine what factors effect on the change of closing Bitcoin price. For analysis, hypotheses were constructed from three dimensions of consumer, industry, and macroeconomics for analysis, and time series data were collected for variables of each dimension. Consumer variables consist of search traffic of Bitcoin, search traffic of bitcoin ban, search traffic of ransomware and search traffic of war. Industry variables were composed GPU vendors' stock price and memory vendors' stock price. Macro-economy variables were contemplated such as U.S. dollar index futures, FOMC policy interest rates, WTI crude oil price. Using above variables, we did times series regression analysis to find relationship between those variables and change of Bitcoin Closing Price. Before the regression analysis to confirm the relationship between change of Bitcoin Closing Price and the other variables, we performed the Unit-root test to verifying the stationary of time series data to avoid spurious regression. Then, using a stationary data, we did the regression analysis. As a result of the analysis, we found that the change of Bitcoin Closing Price has negative effects with search traffic of 'Bitcoin Ban' and US dollar index futures, while change of GPU vendors' stock price and change of WTI crude oil price showed positive effects. In case of 'Bitcoin Ban', it is directly determining the maintenance or abolition of Bitcoin trade, that's why consumer reacted sensitively and effected on change of Bitcoin Closing Price. GPU is raw material of Bitcoin mining. Generally, increasing of companies' stock price means the growth of the sales of those companies' products and services. GPU's demands increases are indirectly reflected to the GPU vendors' stock price. Making an interpretation, a rise in prices of GPU has put a crimp on the mining of Bitcoin. Consequently, GPU vendors' stock price effects on change of Bitcoin Closing Price. And we confirmed U.S. dollar index futures moved in the opposite direction with change of Bitcoin Closing Price. It moved like Gold. Gold was considered as a safe asset to consumers and it means consumer think that Bitcoin is a safe asset. On the other hand, WTI oil price went Bitcoin Closing Price's way. It implies that Bitcoin are regarded to investment asset like raw materials market's product. The variables that were not significant in the analysis were search traffic of bitcoin, search traffic of ransomware, search traffic of war, memory vendor's stock price, FOMC policy interest rates. In search traffic of bitcoin, we judged that interest in Bitcoin did not lead to purchase of Bitcoin. It means search traffic of Bitcoin didn't reflect all of Bitcoin's demand. So, it implies there are some factors that regulate and mediate the Bitcoin purchase. In search traffic of ransomware, it is hard to say concern of ransomware determined the whole Bitcoin demand. Because only a few people damaged by ransomware and the percentage of hackers requiring Bitcoins was low. Also, its information security problem is events not continuous issues. Search traffic of war was not significant. Like stock market, generally it has negative in relation to war, but exceptional case like Gulf war, it moves stakeholders' profits and environment. We think that this is the same case. In memory vendor stock price, this is because memory vendors' flagship products were not VRAM which is essential for Bitcoin supply. In FOMC policy interest rates, when the interest rate is low, the surplus capital is invested in securities such as stocks. But Bitcoin' price fluctuation was large so it is not recognized as an attractive commodity to the consumers. In addition, unlike the stock market, Bitcoin doesn't have any safety policy such as Circuit breakers and Sidecar. Through this study, we verified what factors effect on change of Bitcoin Closing Price, and interpreted why such change happened. In addition, establishing the characteristics of Bitcoin as a safe asset and investment asset, we provide a guide how consumer, financial institution and government organization approach to the cryptocurrency. Moreover, corroborating the factors affecting change of Bitcoin Closing Price, researcher will get some clue and qualification which factors have to be considered in hereafter cryptocurrency study.

The Content of Heavy Metals in Herbal Pills Used as General Processed Food and Risk Assessment of Heavy Metal Intakes (유통 환(丸)제품의 중금속 함량 및 위해성 평가)

  • Kim, Sung-Dan;Jung, Sun-Ok;Kim, Bog-Soon;Yun, Eun-Sun;Chang, Min-Su;Park, Young-Ae;Lee, Young-Chul;Chae, Young-Zoo;Kim, Min-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.7
    • /
    • pp.1038-1048
    • /
    • 2010
  • The purpose of this study was to investigate some heavy metals (Pb, Cd, Cr, Cu, Hg) in 52 commercial herbal pills used as general processed food, to identify weekly heavy metal intakes from herbal pills and to evaluate their potential health risks. The samples were digested with a microwave and determinations of heavy metal residues were carried out by inductively coupled plasma mass spectrometry (ICP-MS) and mercury analyzer. The mean values of heavy metal contents for herbal pills used as general processed food were Pb 0.421 (0.032~1.630), Cd 0.157 (0.011~0.515), Cr 1.033 (0.112~9.933), Cu 6.923 (1.333~16.755), Hg 0.010 (0.001~0.088) mg/kg. Lead contents of herba and cadmium of algae, herba were high (ANOVA-test, p<0.05). Levels of cadmium concentrations exceeding WHO reference values (0.3 mg/kg) were observed in 10 samples (4 species). The significant correlation was observed between Pb and Cd (r=0.633, p<0.01). The weekly intakes of Pb, Cd, Cr, Cu, Hg from herbal pills were 1.112 (0.072~5.088), 1.614 (0.029~9.257), 3.000 (0.252~23.690), 0.182 (0.008~1.235), 0.220 (0.000~0.420)%, respectively, as compared with the Provisional Tolerable Weekly Intake (PTWI) established by Joint FAO/WHO Expert Committee for food safety evaluation. Our data suggest regulations limiting heavy metals in herbal pills used as general processed food.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Green-pepper (풋고추 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Choi, Sung-Gil;Oh, Young-Gon;Kwon, Young-Sang;Hong, Su-Myeong;Sung, Mun-Hyun;Lee, Se-Ja;Hwang, Sun-Young;Seo, Jong-Su
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.211-220
    • /
    • 2016
  • This study was to develop the analytical reference material of green-pepper for multi-residue analysis of pesticides. According to the ISO Guide 35, ISO Guide 13528 and EURL-PT protocol, the homogeneity, stability, assigned value and uncertainty were calculated to assess if it was suitable to be used as the proficiency test or quality control. The values of the within-bottle standard variation ($s_{wb}$) and the between-bottle standard variation ($s_{bb}$) were 1.7~3.7% of assigned value according to the requirement of the ISO guide 35. And, the uncertainty ($u^*{_{bb}}$) due to inhomogeneity was 0.8~1.1% for all pesticides. The storage stabilities of ten-pesticides at various conditions were assessed. For all target pesticides, the slop ($b_1$) values were smaller than the corresponding values of $[t_{0.95,n-2}{\times}s(b_1)]$ specified by the ISO guide 35, indicating that there were no statistically significant decreases in the concentration of the target pesticides when the analytical reference material was stored at room temperature ($20{\sim}30^{\circ}C$) for 7 days, freezing ($-20^{\circ}C$) for 30 days and deep freezer ($-80^{\circ}C$. except for bifenthrin, fenpropathrin) for 245 days. For proficiency test by using it developed by Korea Institute of Toxicology, inter-lab test was performed with eight organization performing the residual pesticide analysis. We found that there were some different results among them. Some were assessed as questionable or unacceptable for two pesticides and one organization didn't analyze the six pesticides. From these results, this green-pepper analytical reference material containing ten-pesticides could be used as a tool for the proficiency test to improve the reliability or consistency for pesticide residue's results.

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

The Correlations between Renminbi Fluctuations and Financial Results of Venture Companies in the Floating Exchange Rate (변동환율제도하의 위안화 환율변동과 벤처기업의 재무성과 간 상관관계 연구)

  • Sun, Zhong-Yuan;Chang, Seog-Ju;Na, Seung-Hwa
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.5 no.1
    • /
    • pp.45-67
    • /
    • 2010
  • On July 21st in 2005, People's Bank of China (PBOC) turned the currency peg against the U.S. dollar into managed currency system based on a basket of unnamed currencies under China's exchanged rate regime. This change means that China's enterprises are not free from currency fluctuations. The purpose of this study is to analyze the relations between Renminbi fluctuations in the floating exchange rate and financial results of venture companies. The process and outcomes of this study are as follows, First, in order to measure the financial results of venture companies, I choose venture companies in Shandong Province listed on the Shanghai Stock Exchange (SSE) at random and several quarter financial sheets according to safety ratios, profitability ratios, growth ratios, activity ratios. Second, I arrange the daily Renminbi exchange rate data announced from July 21st, 2005 to December 31st, 2008 by PBOC into the quarterly data. Third, in order to confirm the relations between Renminbi fluctuations and financial results of venture companies, I carry out Pearson's correlation analysis. As a result, the revaluation of the Chinese Renminbi has weakly negative effects on debt ratio, total assets turnover ratio and equity turnover ratio in statistics. But the revaluation of the Chinese Renminbi is not related to other financial index in statistics. The result of this study is that the revaluation of the Chinese Renminbi has little influence on the export and import of Chinese venture companies and certifies the fact that Chinese venture companies have much foreign currency assets. In addition to avoid the currency exposure risk, this study shows the effective method about currency exposure risk which adjusts proportion of Renminbi to foreign currency.

  • PDF

A Study on LRFD Reliability Based Design Criteria of RC Flexural Members (R.C. 휨부재(部材)의 L.R.F.D. 신뢰성(信賴性) 설계기준(設計基準)에 관한 연구(研究))

  • Cho, Hyo Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1981
  • Recent trends in design standards development in some European countries and U.S.A. have encouraged the use of probabilistic limit sate design concepts. Reliability based design criteria such as LSD, LRFD, PBLSD, adopted in those advanced countries have the potentials that they afford for symplifying the design process and placing it on a consistent reliability bases for various construction materials. A reliability based design criteria for RC flexural members are proposed in this study. Lind-Hasofer's invariant second-moment reliability theory is used in the derivation of an algorithmic reliability analysis method as well as an iterative determination of load and resistance factors. In addition, Cornell's Mean First-Order Second Moment Method is employed as a practical tool for the approximate reliability analysis and the derivation of design criteria. Uncertainty measures for flexural resistance and load effects are based on the Ellingwood's approach for the evaluation of uncertainties of loads and resistances. The implied relative safety levels of RC flexural members designed by the strength design provisions of the current standard code were evaluated using the second moment reliability analysis method proposed in this study. And then, resistance and load factors corresponding to the target reliability index(${\beta}=4$) which is considered to be appropriate level of reliability considering our practices are calculated by using the proposed methods. These reliability based factors were compared to those specified by our current ultimate strength design provisions. It was found that the reliability levels of flexural members designed by current code are not appropriate, and the code specified resistance and load factors were considerably different from the reliability based resistance and load factors proposed in this study.

  • PDF

Health Assessment of Shift Workers in a Automobile Manufacturing Plant (자동차공장 교대작업 근로자들의 건강상태평가)

  • Lee, Jung-Jeung;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.103-121
    • /
    • 1995
  • An investigation on psychophysiological health and social well-being of shift workers been carried out on workers of a automobile manufacturing plant in Ulsan, for 1 month from April, 1993. This cross-sectional survey compared shift workers(n=544) with day workers(n=115). Each subject completed a questionnaire about his personal habit, background, shift schedule, sleep and eating patterns, subjective digestive symptom and psychological well-being and distress using the General Well-Being Schedule(GWB) by self administrated questionnaire that was developed for the U.S. Health and Nutrition Examination Surveys (HANES I). Chi-square analysis was used for discontinuous data and the t-test was used for continous data to determine whether differences noted between the two groups. In terms of sleep quality, a greater percentage of shift workers frequently had trouble getting back to sleep once awakend(p<0.01), and a greater percentage of shift workers awakend tired or sleepy frequently more often than day workers(p<0.05). In rating the quality of their sleep, more shift workers rated their sleep fair to poor than day workers, and greater percentage of shift workers felt tired or sleepy at work two or more times per week(p<0.01) and a much higher percentage of shift workers felt tired or sleepy after work every days(p<0.01). In terms of sleep patterns, a much higher percentage of day workers reported uninterrupted sleep per 24hours than shift workers. The shift workers reported different eating patterns from day workers but there were no statistically significant and rate of their appetite. Thirteen percent of day workers reported the best appetite but only 6.6% of shift workers had the best appetite. The gastric complaints is more frequent in shift workers than day workers(p<0.01). Among subscores in General Well-Being Schedule, anxiety, depression, positive well-being and vitality subscale of shift workers were lower than those of day workers(p<0.05) and general health and self control subscale of shift workers were lower than .those of day workers but there were no statistical significant difference. Based on these study result, it could be concluded that the shift work has significant effects on some psychophysiological conditions of the workers.

  • PDF

A Survey of the Basic Protection Manners of Dental Personnels Against Hepatitis B in and around Seoul (수도권 치과의료 종사자들의 B형 간염에 대한 기초방호실태 및 수행에 관한 조사)

  • Yoon, Mi-Sook;Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 2001
  • The purpose of this study was to examine dental personnels' concern for health, their personal protection manner, and whether or not they were inoculated against hepatitis B and made an inquiry of patients about that. It's ultimately meant to serve as a basis for the preparation of an anti-infection guide for the protection of dental personnels against all sorts of infectious diseases. After a survey was conducted from March 29 through May 9, 2001, the following findings were obtained: (1) The dental personnel group that had worked for 5 to less than 7 years took health examination the most, with 71.4%, before joining the hospital, and 61.5% of those who had served for 9 years or more, the greatest percentage, took medical checkup after joining the hospital(P<0.05). (2) The largest percentage of being inoculated against the anti-B type hepatitis after employment was 71.4% of the dental personnels over 35, and 57.7% of those with 9-year or more working experiences. Therefore, their age and service term made a significant difference(P<0.05). (3) There was no significant gap in personal protection practices between the dental hygienists and nurse aids(P>0.05). But the use of safety goggles for treatment was not properly done, with just 1.48 on the basis of 3 points, whereas the use of mask was scored 2.40 and the use of gloves was scored 1.96. (4) After a narcotic was used once, the leftovers were wasted by 89.7% of the dental hygienists and 70.0% of the nurse aids. More dental hygienists wasted them(P<0.05). (5) For hand washing, antibiotic liquid soap was used by 19.3% of the dental hygienists and 10.0% of the nurse aids, which were both very low percentage. And just 37.2% of the dental hygienists utilized a disposable paper towel to dry their hands, and only 36.0% of the nurse aids used the same(P<0.05).

  • PDF