• Title/Summary/Keyword: u-Safety

Search Result 1,356, Processing Time 0.026 seconds

Estimation of ELF-MF Exposure Levels in the Korean Population through 24-Hour Personal Exposure (개인 노출량 조사를 통한 한국인의 극저주파 자기장 노출 수준)

  • Jung, Joon-Sig;Kim, Keun-Young;Hong, Seung-Cheol;Cho, Yong-Sung;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.18-30
    • /
    • 2012
  • Objectives: The purpose of this study was to estimate the exposure level to extremely low frequency-magnetic fields (ELF-MF) among a selected Korean population using 24-hour personal exposure measurement. Methods: Participants were randomly selected for the measurement of MF exposure under the assumption that the subjects are representative of the overall Korean population. Levels of personal exposure to MF were measured according to the subject's daily activities. Results: The 24-hour time-weighted average (TWA) of 250 participants was $1.56{\pm}4.56$ mG (GM, GSD: 0.79, 2.46 mG). Personal exposure levels for females were higher than for males. The highest personal exposure level was shown in the age group between 20-60 years old. Personal exposure levels according to job category were higher for the non-occupational group than for the occupational group. Conclusions: Our results showed MF exposure exceeding 2 mG per day among 11.3% of the Korean population, indicating a somewhat higher percentage compared to the EMF RAPID Program's results for the U.S population.

Calculation of Low-Energy Reactor Neutrino Spectra for Reactor Neutrino Experiments

  • Riyana, Eka Sapta;Suda, Shoya;Ishibashi, Kenji;Matsuura, Hideaki;Katakura, Jun-ichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.155-159
    • /
    • 2016
  • Background: Nuclear reactors produce a great number of antielectron neutrinos mainly from beta-decay chains of fission products. Such neutrinos have energies mostly in MeV range. We are interested in neutrinos in a region of keV, since they may take part in special weak interactions. We calculate reactor antineutrino spectra especially in the low energy region. In this work we present neutrino spectrum from a typical pressurized water reactor (PWR) reactor core. Materials and Methods: To calculate neutrino spectra, we need information about all generated nuclides that emit neutrinos. They are mainly fission fragments, reaction products and trans-uranium nuclides that undergo negative beta decay. Information in relation to trans-uranium nuclide compositions and its evolution in time (burn-up process) were provided by a reactor code MVP-BURN. We used typical PWR parameter input for MVP-BURN code and assumed the reactor to be operated continuously for 1 year (12 months) in a steady thermal power (3.4 GWth). The PWR has three fuel compositions of 2.0, 3.5 and 4.1 wt% $^{235}U$ contents. For preliminary calculation we adopted a standard burn-up chain model provided by MVP-BURN. The chain model treated 21 heavy nuclides and 50 fission products. The MVB-BURN code utilized JENDL 3.3 as nuclear data library. Results and Discussion: We confirm that the antielectron neutrino flux in the low energy region increases with burn-up of nuclear fuel. The antielectron-neutrino spectrum in low energy region is influenced by beta emitter nuclides with low Q value in beta decay (e.g. $^{241}Pu$) which is influenced by burp-up level: Low energy antielectron-neutrino spectra or emission rates increase when beta emitters with low Q value in beta decay accumulate Conclusion: Our result shows the flux of low energy reactor neutrinos increases with burn-up of nuclear fuel.

Research on Consumer Awareness Due to Origin Declaration of Beef in General Restaurant (일반음식점의 쇠고기 원산지 표시에 대한 소비자 인식 연구)

  • Lee, Seung-Mi;Jin, Yang-Ho
    • Culinary science and hospitality research
    • /
    • v.15 no.3
    • /
    • pp.112-127
    • /
    • 2009
  • In 2007, due to the outcome of the Korea-U.S. FTA negotiations, the opportunities for American beef greatly increased and a serious change in the domestic dining market is expected. The market currently faces issues such as the settlement of the beef origin declaration policy and the fulfillment of customer needs on domestic and imported beef. The following are the summary of the results of the aforementioned research and analysis. First, the consumer awareness level of origin declarations was comparatively low. Second, the reason behind the propensity for imported beef was the comparatively cheaper price despite the lower taste quality, and it was determined that there is a high level of distrust on domestic beef sold in general restaurants. Third, domestic beef showed a high valuation in taste, safety and freshness, while imported beef showed results which were below average. Concluding from the above research results, a dining environment should be created where consumers can trust what they eat through settlement of an origin declaration policy, and more efforts should be put into fulfilling consumer needs for both domestic and imported beef.

  • PDF

A Study on Opinion of Korean Feminine Seniors on the Life Support Appliances for Healthy Ageing - Medication Dispenser, Video Phone, Activity Monitor, Sleep Monitor - (재가노인 생활지원기기에 대한 한국 여성노인의 인식 - 알약분배기, 비디오폰, 활동모니터, 취침모니터를 중심으로 -)

  • Steggell, Carmen D.;Park, Kyoung-Ok;Kim, Sun-Joong;Kwon, Myoung-Hee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.4
    • /
    • pp.83-96
    • /
    • 2008
  • The purpose of this study is to grasp the opinion of Korean feminine seniors on the life support appliances for their healthy ageing: medication dispenser, video phone, activity monitor and sleep monitor. The focus group interviews, asking the usability of the appliances, were answered by each 6 feminine seniors of more than 65 years, residing in Corvallis of U.S.(group I), Cheongju(group II), and Ulsan(group III) of Korea. The results are as follows. (1) The medication dispenser proved to be very useful to all the respondents. All the seniors, who take more than one medicine a day, felt it helpful that the medication dispenser makes them to take medicines at fixed time. In addition, they hoped the medicine envelope to be developed for the dispenser use by the supply side. (2) The seniors showed interest in the manner the video phone works; to work by the voice, rather than by the finger. They expressed the hope of the video phone to display the communication contents, in consideration of their weakening hearing. (3) The seniors who live alone, especially, felt intimacy to the activity monitor, thinking as if some helpers were beside them. The fact that it can send emergency calls immediately when situations happen, gave the seniors emotional safety as a patron. (4) The sleep monitor, although essential to the serious cases without moving ability, was proved less necessary to the healthy seniors. They expressed the hope of this appliance to be evolved for the use with the mattress without bed.

A Study on the Improvement of Domestic Legislative System for Crime-Safe Environment in Residental Area (주거지역 방범환경 조성을 위한 국내 법.제도의 현황과 개선방안에 대한 연구)

  • Choi, Jae-Eun;Kim, Sei-Yong;Jeong, Yun-Nam
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.155-160
    • /
    • 2009
  • Safety of residents could be considered and then increased when we plan, design, and operate a city. In Korea, CPTED (Crime Prevention through Environmental Design) is currently being applied to new towns. However, it is not systemized and neither efficient, for there are no constraint provisions, and the foreign cases are not specifically customized to the current situation of the country. This means, the introduction of CPTED is an indispensable fact, but there are limits to the budget aids and actual application, for there is no legal base to support it. This study, therefore, aims to find the limits from analyzing related laws and regimes, administrative regulations, and applied cases, and to deduct improvement plans based on examined foreign cases. In this Study, the supporting system of foreign CPTED related laws and regulations was analyzed around the cases of England and U.S.A, and based on that information, the present condition and limits of CPTED related laws and regulations of Korea were deducted. As a result of this study, there were no constraint provisions to apply the design guidelines to actual planning, and there were limits on backup aid and actual application due to the lacking of analyzing the relevant area. Also, an acceptable framework must be arranged by the revision of laws and ordinances to compel the system, and link it with the CPTED certification system which will revitalize the whole system.

  • PDF

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Designing FMH Impact-Absorbing Structure by Using Subcomponent Collapse Simulation (단품 압궤 시뮬레이션을 이용한 FMH 충격흡수부재의 설계방법에 관한 연구)

  • Kim, Ji-Hun;Jun, In-Ki;Choi, Jae-Min;Kim, Sung-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1113-1118
    • /
    • 2010
  • It is requested that the interior compartment of a passenger vehicle must be satisfied with the FMVSS201U regulation, FMH impact test. It is needed the design methodology to find the appropriate structure about the FMH impact. When designing the impact-absorbing structure for the FMH impact test, it is to be noted that the impact absorber must have different performance considering the stiffness of the vehicle as the impact position and approach angle of FMH. In this study, an efficient design methodology was developed by using subcomponent collapse simulation instead of conducting full-vehicle simulation, thereby reducing the time and resources spent. Further, this unit-model simulation helps optimize the impact absorbing structure.

Improving Two-way Road Functionality by Using Shoulder (길어깨를 활용한 2차로 도로 기능개선 방안 연구)

  • Choi, Keechoo;Shim, Sangwoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1551-1558
    • /
    • 2013
  • The purpose of this study is deriving proper plan which is improving functionality of three-way intersection in two-way road by using shoulder. Alternatives of this study were considered as installation of yield lane and application of TWLTLs (Two-Way Left-Turn Lanes). Case studies to utilize alternatives were limited to national and local roadways which is wider than 11 meters due to be required 3 lanes. Under various traffic conditions such as traffic volume of each direction and left-turn, alternatives were analyzed by simulation. As a results, application of TWLTLs was better than installation of yield lane in terms of improving rate (8.0% vs. 3.7%). Application of TWLTLs is supposed to better alternative, however enough driver education is required to improving safety because it is different with existing driving pattern and/or behaviors. Some limitations and future research agenda have also been discussed by on-site inspections.

Benzidine Induces Epithelial-Mesenchymal Transition of Human Bladder Cancer Cells through Activation of ERK5 Pathway

  • Sun, Xin;Zhang, Tao;Deng, Qifei;Zhou, Qirui;Sun, Xianchao;Li, Enlai;Yu, Dexin;Zhong, Caiyun
    • Molecules and Cells
    • /
    • v.41 no.3
    • /
    • pp.188-197
    • /
    • 2018
  • Benzidine, a known carcinogen, is closely associated with the development of bladder cancer (BC). Epithelial-mesenchymal transition (EMT) is a critical pathophysiological process in BC progression. The underlying molecular mechanisms of mitogen-activated protein kinase (MAPK) pathway, especially extracellular regulated protein kinases 5 (ERK5), in regulating benzidine-induced EMT remains unclarified. Hence, two human bladder cell lines, T24 and EJ, were utilized in our study. Briefly, cell migration was assessed by wound healing assay, and cell invasion was determined by Transwell assay. Quantitative PCR and western blot were utilized to determine both gene expressions as well as protein levels of EMT and MAPK, respectively. Small interfering RNA (siRNA) was transfected to further determine ERK5 function. As a result, the migration and invasion abilities were enhanced, epithelial marker expression was decreased while mesenchymal marker expression was increased in human BC cell lines. Meanwhile, benzidine administration led to activation of ERK5 and activator protein 1 (AP-1) proteins, without effective stimulation of the Jun N-terminal kinase (JNK) or p38 pathways. Moreover, Benzidine-induced EMT and ERK5 activation were completely suppressed by XMD8-92 and siRNAs specific to ERK5. Of note, ERK1/2 was activated in benzidine-treated T24 cells, while benzidine-induced EMT could not be reversed by U0126, an ERK1/2 inhibitor, as indicated by further study. Collectively, our findings revealed that ERK5-mediated EMT was critically involved in benzidine-correlated BC progression, indicating the therapeutic significance of ERK5 in benzidine-related BC.

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF