• 제목/요약/키워드: two-step pulse

검색결과 99건 처리시간 0.03초

2 단계 펄스 주입을 이용한 프로그램 방법에서 백바이어스 효과 (Back bias effects in the programming using two-step pulse injection)

  • 안호명;장영걸;김희동;서유정;김태근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.258-258
    • /
    • 2010
  • In this work, back bias effects in the program of the silicon-oxide-nitride-oxide-silicon (SONOS) cell using two-step pulse sequence, are investigated. Two-step pulse sequence is composed of the forward biases for collecting the electrons at the substrate terminal and back bias for injecting the hot electrons into the nitride layer. With an aid of the back bias for electron injection, we obtain a program time as short as 600 ns and an ultra low-voltage operation with a substrate voltage of -3 V.

  • PDF

Flash EEPROM의 two-step 프로그램 특성 분석 (Analysis of Two-step programming characteristics of the flash EEPROM's)

  • 이재호;김병일;박근형;김남수;이형규
    • 전자공학회논문지D
    • /
    • 제34D권9호
    • /
    • pp.56-63
    • /
    • 1997
  • There generally exists a large variation in the thereshold voltages of the flash EEPROM cells after they are erased by using th fowler-nordheim tunneling, thereby getting some cells to be overeased. If the overerased cells are programmed with the conventional one-step programming scheme where an 12-13V pulse with the duration of 100.mu.S is applie don the control gate for the programming, they can suffer from the significant degradation of the reliability of the gate oxide. A two-step programming schem, where an 8/12 V pulse with a duration of 50.mu.S for each voltage is applied on the control gate for the programming, has been studied to solve the problem. The experimental results hav eshown that there is little difference in the programming characteristics between those two schemes, whereas the degradation of the gate oxide due to the programming can be significantly reduced with the two-step programming scheme compared to that with the one-step programming scheme. This is possibly because the positive charge stored in the floating gate of the overerased cells is compensate dwith the electrons injected into the floating gate while the 8V pulse is applied on the control gate, which leaves the overerased cells in the normally erased state after the duration of the 8V pulse.

  • PDF

Research on a New 12-Pulse Step-Up and Step-Down Aviation Auto-Transformer Rectifier

  • Jiang, Fan;Ge, Hong-juan;Dong, Xiao-xu;Zhang, Lu
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.266-276
    • /
    • 2018
  • This paper presents a new step-up and step-down multi-pulse auto-transformer rectifier unit (ATRU) topology. This structure can achieve a wide range of output voltages, which solves the problem of auto-transformer output voltage being difficult to regulate. Adding middle taps to the primary winding and reasonably setting the number of auto-transformer windings, constituted two groups of three-phase output voltages with a $30^{\circ}$ phase difference. Multi-pulse output DC voltage is obtained after a three-phase output voltage across two rectifier bridges and inter-phase reactor. Thus, the output DC voltage is related to the number and configuration of the auto-transformer winding. In this paper, the relationship between the voltage ratio of the auto-transformer and the ratio of winding, input current and auto-transformer kilovoltampere rating are deduced and validated by simulations. On this basis, the output voltage range is optimized. An experiment on two different voltage ratio principle prototypes was carried out to verify the correctness of the analysis design.

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

Effects of Temperature Coefficients for Dielectric Constants on Thermoreflectances and Thermal Responses of Metal Thin Films Exposed to Ultrashort Pulse Laser Beams

  • Seungho Park
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2002
  • Effects of temperature coefficients fur dielectric constants on transient reflectances and thermal responses have been investigated for a metal(gold) thin-film during ultrashort pulse laser heating. Heating processes are simulated using the conventional conduction model(parabolic one-step, POS), the parabolic tow-step model(PTS), the hyperbolic two-step model(HTS). Results fro the HTS model are very similar to those from the PTS model, since the laser heating time in this study is considerably greater than the electron relaxation time. PTS and HTS models, however, result in completely different temperature profiles from those obtained by the POS model due to slow electron-lattice interactions compared to laser pulse duration. Transient reflectances are directly estimated from the linear relationship between electron temperature and complex dielectric constants, while conventional approaches assume that the change in reflectances is proportional to that in temperatuer. Reflectances at the front surface vary considerably for various dielectric constants, while those at the rear surface remain unchanged relatively.

선형 펄스 전동기의 특성 해석 (The Charcteristics Analysis of Linear Pulse Motor)

  • 조윤현;이광호;김성도
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.249-256
    • /
    • 1999
  • This paper describes static characteristics analysis of linear pulse motor(LPM) with two permanent magnets. Linear pulse motors are finding a wide range of application for the Factory-Automation or the Office-Automation. Typically, LPM provides for a reliable and precise control of position, velocity, or acceleration without using a closed-loop system. Some of the advantages of LPMs are ease of control, step multiplication, static and dynamic positioning, and locking force. The flux density and thrust of LPM is computed by the FEM and magnetic equivalent circuits which considered the magnetic nonlinear phenomena. The result of characteristics analysis are shown as the flux, the air gap reluctance and the thrust. The velocity and position characteristics as a function of unit step input is measured. To estimate the unit step response charecteristic of LPM, the simulation results by Matlab and the experimental results is compared.

  • PDF

펄스열의 2차 차분을 이용한 2단 stagger 신호 식별 (An Identify of Two Step Stagger Signals Using the Second Deviation of Pulse Train)

  • 임중수;홍경호;이득영;신동훈;김용환
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1536-1541
    • /
    • 2009
  • 본 논문은 2단 스태거 펄스열을 사용하는 레이더 신호를 분리하는 전자전 장비의 알고리즘에 관한 연구이다. 일반적으로 레이더는 고정된 펄스열을 사용하였으나 최신 레이더들은 전자보호 기능을 강화하기 위해서 펄스열을 바꾸고 있다. 2단 스태거 펄스신호는 2가지의 펄스반복주기를 교대로 사용하여 레이더의 탐지 성능을 향상시키고 전자보호 능력을 향상시키는 좋은 방법이다. 종래에는 히스토그램 방법을 사용하여 스태거 신호를 식별하였으나, 본 논문에서는 펄스열의 2차 차분을 이용하는 방법으로 신호를 식별하였으며, 종래에 사용하던 방법과 비교해서 처리 속도가 매우 빠르다. 제안된 알고리즘은 2단 스태거 펄스열을 포함한 각종 펄스열을 분리하는 특성이 매우 양호하였다.

새로운 블럭펄스 적분연산행렬을 이용한 비선형계 최적제어 (Optimal Control of Nonlinear Systems Using The New Integral Operational Matrix of Block Pulse Functions)

  • 조영호;심재선
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권4호
    • /
    • pp.198-204
    • /
    • 2003
  • In this paper, we presented a new algebraic iterative algorithm for the optimal control of the nonlinear systems. The algorithm is based on two steps. The first step transforms nonlinear optimal control problem into a sequence of linear optimal control problem using the quasilinearization method. In the second step, TPBCP(two point boundary condition problem) is solved by algebraic equations instead of differential equations using the new integral operational matrix of BPF(block pulse functions). The proposed algorithm is simple and efficient in computation for the optimal control of nonlinear systems and is less error value than that by the conventional matrix. In computer simulation, the algorithm was verified through the optimal control design of synchronous machine connected to an infinite bus.

스텝모터의 진동 저감을 위한 마이크로 스텝 구동에 관한 연구 (A Study on the Micro Stepping Drive to Reduce Vibration of Step Motor)

  • 신규범;이정우;오준호
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.118-127
    • /
    • 1997
  • In this study, We use microstep control to reduce vibration of step motor. Microstep control of step motor is usually thought of as an extension of conventional step motor control technology. The essence of micro stepping is that we divide the full step of a step motor into a number of substep called microstep and cause the stepmotor to move through a substep per input pulse. In ideal case, by controlling the individual phase currents of a two-phase step motor sinusoidally we can get uniform torque and step angle. But due to the nonlinear characteristics of the step motor, we need to compensate current waveform to improve the over-all smoothness of the conventional micro stepping system. We implement digital Pulse Width Modul- ation (PWM) driver to drive step motor and microphone was used for detecting vibration. Driver enables speed change automatically by increasing or decreasing micro stepping ratio which we call Automatic Switching on the Fly. To compensate the torque harmonics, neural network is applied to the system and we found compensated optimal input current waveform. Finally we can get smooth motion of step motor in a wide range of motor speed.

  • PDF