• Title/Summary/Keyword: two-phase inverter

Search Result 327, Processing Time 0.022 seconds

A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme (2상 및 3상 변조된 각상별 랜덤 펄스위치 펄스폭 변조기법의 성능비교)

  • Wi Seog-Oh;Lim Young-Cheol;Jung Young-Gook;Na Seok-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.347-354
    • /
    • 2002
  • In this paper, a comparative study on the performance of two-phase and three-phase randomized pulse position PWM scheme for mitigation of audible switching acoustic noise in motor drives Is done. In the randomized pulse position PWM, each of two-phase or three-phase PWM pulses is located randomly in each switching interval. Simulation and experimental efforts were executed to investigate the spread effects of power spectra of inverter output voltage, waveforms of ripple current and audible switching acoustic noise.

  • PDF

Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM (6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘)

  • Kim, Seong-Hoon;Jang, Won-Jin;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

Control Strategy to Interconnect the Utility Line for 3-Phase Inverter (태양광발전 시스템용 인버터의 계통연계 제어)

  • Jung, Young-Seok;Lee, Jung-Thae;Jung, Myung-Wong;Yu, Gwon-Jong;Song, Jin-Soo;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.336-338
    • /
    • 1996
  • In this paper, a simple control strategy to interconnect the utility line system for three-phase inverter. Conventionally, such interconnection is based on the 3-phase time-domain waveform analysis, though the control based on the plane defined by the two-axis theory is common in the area of the motor control. The new instantaneous power control strategy is introduced, which is based on the d-q axis theory. Simulation results show that proposed control method has good controllability with simple strategy.

  • PDF

Consideration of the Carrier Based Signal Injection Method in Three Shunt Sensing Inverters for Sensorless Motor Control

  • Jung, Sungho;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1791-1801
    • /
    • 2016
  • This paper considers a carrier based signal injection method for use in the three shunt sensing inverter (TSSI) for sensorless motor control. It also analyzes the loss according to the injection axis of the voltage signal. To remove both the phase current and rotor position sensors, a sensorless method and a phase current reconstruction method can be simultaneously considered. However, an interaction between the two methods can be incurred when both methods inject voltage signals simultaneously. In this paper, a signal injection based sensorless method with the 120° OFF Discontinuous PWM (DPWM) is implemented in a TSSI to avoid this interaction problem. Since one leg does not have a switching event for one sampling period in the 120° OFF DPWM, the switching loss is altered according to the injection axis. The switching loss in the d-axis injection case can be up to 32% larger than that in the q-axis injection case. Other losses according to the injection axis are also analyzed.

Static Overmodulation Strategies of Two Phase Full Bridge Inverter (2상 풀브릿지 인버터의 정적 과변조 기법)

  • Choi, Seung-Cheol;Kim, Young-Ki;Kim, Sang-Hoon;Kim, Hyeong-Cheol;Mok, Hyung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.45-46
    • /
    • 2010
  • In this paper, the static overmodulation is proposed for the 2-phase full bridge inverter. The overmodulation strategy increases a fundamental output voltage and improves a voltage utilization up to the maximum in the overmodulation range. To maintain a linearity of the relation between a reference voltage and a fundamental output voltage, this paper suggests a compensation voltage, whose magnitude or phase is modified to the proposed control scheme. Simulation and experimentation results demonstrate the effectiveness of the proposed algorithms.

  • PDF

Characteristics of the Stress Reduction and Output Voltage of ST(Switched Trans) Quasi Z-Source Inverter (ST Quasi Z-소스 인버터의 스트레스 저감과 출력전압 특성)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This paper proposes a ST(Switched Trans) quasi Z-source inverter using a Switched Trans Cell combing the characteristics of a Switched Inductor Cell and Trans. A DC link inductor of the conventional quasi Z-source inverter is alternated with Switched Trans Cell of the proposed ST quasi Z-source inverter. Trans Cell of the proposed method consists of one Trans and two diodes, and the proposed method has higher and more various boost function than the conventional quasi Z-source inverter by simply changing the turns ratio of primary and secondary of the Trans. The validity of the proposed ST Z-source inverter was confirmed by PSIM simulation and a DSP based experiment under the input voltage 48V and output phase voltage 30V. As a result, when compared with the traditional quasi Z-source inverter, the proposed method has the advantage of the low voltage stress under the same output voltage condition of the voltage.

Single phase induction motor driving system using auxiliary resonant DC-DC converter (보조 공진 DC-DC컨버터를 이용한 단상 유도 전동기 구동 시스템)

  • Lee, S.H.;Mun, S.P.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1190-1192
    • /
    • 2002
  • These days, electromagnetic radiation noise and switching losses of static converter become harmful. Many resonant inverters with radiation techniques solve their such problems. Auxiliary Resonant Commutated Pole Inverter (ARCP) was proposed. but it has two demerits. In circuit configuration. It isn't constructed by 2 in 1 IGET modules. Besides, control is complicated because of neutral point voltage control and boost current control. This paper proposes a new auxiliary resonant inverter which solved two demerits. In addition, it deals efficiency which compared with hard switching inverter and result of separation of power loss

  • PDF

The Driving Characteristics of Two-Phase Sinusoidal in Ultrasonic motor (초음파 모터의 2상 정현파 구동특성)

  • Choi, Jung-Seok;Baek, Soo-Hyun;Kim, Yong;Yoon, Shin-Yong;Choi, Chul-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.100-102
    • /
    • 2002
  • In this paper the driving characteristic for a traveling-wave type ultrasonic motor is described. For driving of ultrasonic motor, a two-phase resonant inverter and Digital IC was made. The driving circuit simulation results are compared with measured frequencis and amplitudes.

  • PDF

Reduction of Audible Switching Acoustic Noise in Motor Drives by a New Two Phase Random Pulse Position PWM Scheme (새로운 2상 랜덤 펄스 위치 PWM기법에 의한 모터 구동 시스템의 가청 스위칭 소음 저감)

  • Wi, Seog-Oh;Lim, Young-Cheol;Na, Seok-Hwan;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.82-89
    • /
    • 2002
  • In this paper, a new two-phase space vector RPWM(Random PWM) is proposed. In the proposed RPWM, each of two-phase PWM pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of inverter output voltage, d.c link current and audible switching acoustic noise as in the case of randomly changed switching frequency. To verify the validity of the proposed two-phase RPWM scheme, the experiment based on the C167 micro-controller was executed. The performance of the proposed scheme was compared with traditional PWM schemes experimentally.

  • PDF

A Study on IGBT inverter for sinusoidal wave output PAM type (정현파(正弦波) 출력(出力) PAM형(形) IGBT 인버터에 관한 연구(硏究))

  • Lee, Hyun-Woo;Park, Jong-Gi;Lee, Soo-Heum;Kwon, Soon-Kurl;Suh, Ki-Young;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.611-614
    • /
    • 1991
  • In variable speed driving system of three phase induction motor controlled by an inverter, because of the switching of semiconductor devices in inverter, an appreciable amount of harmonic components of voltage waveform can cause the motor to generate losses, torque ripple, acoustic noise and oscillation of semiconductor devices. In this paper a new PAM type PWM inverter using IGBT is described. The output waveforms in the proposed PAM type PWM inverter are investigated both theoretiically and experimentally. The line-voltage waveform is composed of fundamental component and the sidebands of carrier frequency. The lower order harmonics are not included in the output wave form. As each inverter arm does not operate during two-thirds period, the heats, generated in the devices are reduced. That is, the size of the inverter system can he minimized because of the reduction in the heat dissipating equipment.

  • PDF