• Title/Summary/Keyword: two-phase flow nozzle

Search Result 103, Processing Time 0.024 seconds

Design Modification and Correlation Verification between Reattachment Flow of Dispersed Jet and Local Thinning of Feedwater Heater (충돌로 인해 분산된 2상 제트스팀의 재부착 현상과 국부 감육 상관관계 규명 및 설계개선에 관한 연구)

  • Kim, Hyung-Joon;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.483-495
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line-inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

CFD simulation of a prefilming air blast fuel nozzle (Prefilming air blast 연료 노즐의 다상유동 및 반응 유동장 수치해석)

  • Jung, Seungchai;Kim, Shaun;Park, Heeho;Ryu, Shiyang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.251-253
    • /
    • 2017
  • Numerical study of air-blast type injector for low emission aircraft engines was conducted. Volume-of-fluids approach was used to track interface of fuel and air. Primary atomization of fuel stream was visualized, and thickness and mean velocity at the injector exit was calculated. Liquid fuel injected from fuel slots joined together as a thin film on preflimer surface, and interacted with swirling air. As instability on the fuel surface increased, separation of fuel as ligaments and droplets occured. The film thickness and velocity were used to as fuel injection boundary condition for reactive flow simulation. Primary reaction zone was formed in vicinity of the fuel nozzle, creating a stable flame inside the combustor.

  • PDF

Measurement of Bubble Diameter and Rising Velocity in a Cylindrical Tank using an Optical Fiber Probe and a High Speed Visualization Technique (광섬유 탐침과 고속가시화 기법을 이용한 원형탱크 내부의 기포직경 및 상승속도 측정)

  • Kim, Gyurak;Choi, Seong Whan;Kim, Yoon Kee;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.2
    • /
    • pp.14-19
    • /
    • 2012
  • An optical fiber probe system for measuring the local void fraction in the air-water two-phase flow was developed with a 1550 nm light source. Air was injected through a nozzle placed in the center of the bottom wall of a water-filled cylindrical tank. The optical fiber probe having a diameter of $125{\mu}m$ was sufficiently thin to resolve the air-water interface of the bubbly flows. To verify the performance of the optical fiber probe, the synchronized high speed visualization study using a high speed camera was carried out. Comparison between the optical signals and the instantaneous bubble diffraction images confirms that the optical fiber probe is very accurate to measure the void fraction in two-phase flows. The estimated bubble diameter and the rising velocity by the optical fiber probe have 1% and 5% of accuracy, respectively.

The Effects of Coolant Inventory and Noncondensible Gas on the Natural Circulation in a PWR Loop System (PWR루프계통에서 냉각재 재고량 및 비응축성 가스의 자연순환에 미치는 영향)

  • Cha, Jong-Hee;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.308-320
    • /
    • 1989
  • The objective of this work is to investigate the effects of diminished primary coolant inventory and the presence of noncondensible gas during single- and two-phase natural circulation in a PWR loop model. The test model was composed of two loops with a U-tube heat exchanger in each loop. Through a series of tests, it has been confirmed that the two-phase natural circulation flow rates were greatly dependent on primary coolant inventory as previous investigators observed. The primary coolant inventory limit to maintain two-phase natural circulation was found to be the amount of the coolant necessary to keep the waterline of the coolant nozzle hole center in this model. The presence of noncondensible gas impede the single-phase natural circulation, but it did not affect the two-phase natural circulation significantly.

  • PDF

Feature of Spray Transport and Atomization from Two-Phase Swirling Jet with Air-to-Liquid Mass Ratio (공기액체질량비에 따른 이류체 선회형 분사의 분무거동 및 미립화 특성)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Experiments were performed in a two-phase swirling spray facility that has been described elsewhere. Measurements of spray transport and drop size distribution are analyzed over wide ranges of air to liquid mass flow ratios, utilizing four different internal mixing pneumatic nozzles. The spatial distributions of mean velocities. fluctuating velocities, and velocity-diameter correlation were quantitatively analyzed. Also, the exponential correlation curves were obtained with ALR along the spray centerline, which indicated an approximately identical formulation regardless of ALR. It indicated that the atomization characteristics were remarkably superior in the case of 30o of swirl angle with higher ALR. Among other things. nozzle configuration is one of the significant parameters affecting spray phenomena from an internal mixing nozzle. Turbulence intensities are increasingly degenerated with an increase of nozzle configuration, allowing a rapid increment of drop size distribution.

Numerical Analysis of Partial Cavitaing Flow Past Axisymmetric Cylinders (축대칭 실린더형상 주위 부분공동 유동의 전산해석)

  • Kim, Bong-Su;Lee, Byung-Woo;Park, Warn-Gyu;Jung, Chul-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.69-78
    • /
    • 2009
  • Cavitating flow simulation is of practical importance for many hydraulic engineering systems, such as pump, turbine, nozzle, injector, etc. In the present work, a solver for cavitating flow has been developed and applied to simulate the flows past axisymmetric cylinders. Governing equations are the two-phase Navier-Stokes equations, comprised of continuity equation of liquid and vapor phase. The momentum equation is in the mixture phase. The solver employed an implicit, dual time, preconditioned algorithm in curvilinear coordinates. Computations were carried out for three axisymmetric cylinders: hemispherical, ogive, and caliber-0 forebody shape. Then, the present calculations were compared with experiments and other numerical results to validate the present solver. Also, the code has shown its capability to accurately simulate the re-entrant jet phenomena and ventilated cavitation. Hence, it has been found that the present numerical code has successfully accounted for cavitating flows past axisymmetric cylinders.

Numerical Prediction of Chamber Performance for OWC Wave Energy Converter (OWC 파력발전장치의 공기실 성능예측에 대한 수치적인 연구)

  • Jin, Ji-Yuan;Hyun, Beom-Soo;Liu, Zhen;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.91-98
    • /
    • 2010
  • The water elevation inside the air chamber and bi-directional air flow in the duct of Oscillating Water Column wave energy converter is one of the most important factors to evaluate the operating performance. The numerical wave tank based on the commercial software Fluent 6.2 in the present paper is employed to generate the incident waves. The numerical wave tank consists of the continuity equations, the Reynolds-averaged Navier-Stokes equations and the two-phase VOF function. The oscillating amplitude of water column in the chamber and bi-directional air flow in the duct installed on the top of the chamber are calculated, and compared with experimental data to verify the validation of the present NWT. The nozzle effects of the chamber-duct system on the relative amplitudes of the inner free water surface and air flow rate in the duct are investigated.

A Study on the Flow Characteristics of an Intermittent Fuel Spray (간헐적인 연료분무의 유동특성에 관한 연구)

  • Kim, Won-Tae;Gang, Sin-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1198-1206
    • /
    • 1997
  • The flow characteristics of an intermittent fuel injection into a stationary ambient air were investigated using gasoline. The measurements were made by two-channel, air cooling type Phase Doppler Anemometer(PDA) system (DANTEC, 750 MW). And a pintle type injector of MPI (Multi-point Port Injection) system was utilized as a fuel injector. The PDA receiver optic was set up in a 60.deg. C forward scatter arrangement to obtain the optimum scattering signal of fuel droplets. The data were obtained by synchronizing PDA system with the fuel injection period, and the axial and radial velocity and turbulent components of fuel droplets were mainly measured for the analysis of temporal and spatial distribution depending upon the fuel injection pressures.

A Study for the Effect of Liquid Droplet Impingement Erosion on the Loss of Pipe Flow Materials (배관 재질 손상에 미치는 액적충돌침식의 영향에 대한 연구)

  • Kim, Kyung Hoon;Cho, Yun Su;Kim, Hyung Joon
    • Journal of ILASS-Korea
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • Wall thinning of pipeline in power plants occurs mainly by flow acceleration corrosion (FAC), cavitation erosion (C/E), liquid droplet impingement erosion (LDIE). Wall thinning by FAC and C/E has been well investigated; however, LDIE in plant industries has rarely been studied due to the experimental difficulty of setting up a long injection of highly-pressurized air. In this study, we designed a long-term experimental system for LDIE and investigate the behavior of LDIE for three kinds of materials (A106B, SS400, A6061). The main control parameter was the air-water ratio (${\alpha}$), which was defined as the volumetric ratio of water to air (0.79, 1.00, 1.72). In order to clearly understand LDIE, the spraying velocity (${\nu}$) of liquid droplets was controled larger then 160 m/s and the experiments were performed for 15 days. Therefore, this research focuses relation between erosion rate and air-water ratio on the various pipe-flow materials. NPP(nuclear power plant)'s LDIE prediction theory and management technique were drawn from the obtained data.

On the Optimum Modelization for a Spray Column Direct Contact Heat Exchanger (분사칼럼식 직접접촉 열교환기의 최적 모델링을 위한 연구)

  • Yoon, S.M.;Kang, Y.H.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1991
  • The purpose of this study is to lay groundwork for a complete analysis of two component flow by analyzing a single component flow made of continuous fluid without dispersed phase. In order to achieve uniform velocity distributions which are desirable in designing an optimum spray column direct contact heat exchanger, the influence of injection nozzle orientation has been investigated for axial and radial injections. The results that radial injection ensures more uniform velocity distributions compared to the axial case. The flow characteristics in a spray column have been investigated with various L/D values and inlet velocities, the most uniform internal velocity distributions have been obtained for the case of L/D=10 and 0.1m/sec. In the present investigation, it is shown that radial injection method for the continuous flow is advantageous in obtaining desirable uniform velocity distributions in a spray column. It is also found that as the value of L/D increases and the inlet velocity decreases, the flow improves to be better uniform velocity distributions.

  • PDF