• 제목/요약/키워드: two-mode

검색결과 5,147건 처리시간 0.04초

암환자와 가족원의 스트레스와 대처방법 차이 (The Comparison of the Stress and Coping Methods of Cancer Patients and Their Caregivers)

  • 김희승
    • 대한간호학회지
    • /
    • 제33권5호
    • /
    • pp.538-543
    • /
    • 2003
  • Purpose: The purpose of this study was to identify the stress and the coping methodes in the cancer patients and their caregivers. Method: The stress method was measured by V AS(Visual Analogue Scale). The coping methodes was measured using the modified Ways of Coping Questionnaire. The phases of patient illness consisted of Ist(initial) stage, and 2nd(recurred) stage and 3rd(terminal) stage based on Lewandowski & Jones(1988) method. The data were collected by a survey of convenience sampling of 257 cancer patients and 196 of their caregivers from two hospitals in Seoul. The data were analyzed using paired t-test, unpaired t-test. Result: The stress level of cancer patients was lower than their caregivers. The cancer patients used emotion-focused coping mode than problem-focused coping mode. The caregivers problem-focused coping mode over emotion-focused coping mode. In the problem-focused coping mode, the caregivers significantly used two coping strategies that were ‘positve cope’, ‘information seeking’ more than patients. In emotion-focused coping mode, the caregivers significantly used one coping strategies that was ‘wish’ more than patients. The patients tended to used two coping strategies that were ‘blame’ and ‘emotion expression’ more than the caregivers. Conclusion: Further study needs to be done to positively identify these coping methods and develop interventions to assist patients and their caregivers.

유체로 연성되고 두께가 상이한 두 직사각 평판의 실험적 모드 해석 (Experimental Modal Analysis of Two Unequal Rectangular Plates Coupled with Fluid)

  • 유계형;정경훈;이성철
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2541-2549
    • /
    • 2002
  • In order to study the vibration characteristics of fluid-structure interaction problem, two rectangular plates coupled with bounded fluid were investigated. Experimental modal analyses were carried out to extract the modal parameters of the system. Additionally. finite element modal analyses performed using a commercial computer code, ANSYS. The FEM solutions were compared with the experimental solutions to verify the finite element model. As a result, the comparison between the experiment and FEM results showed excellent agreement. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The thickness effect of the plates on the fluid-coupled natural frequencies and mode shapes was investigated for two different cases with the identical thickness and the unequal thickness. It was found that the coupled natural frequencies increase with the thickness for the identical plates regardless of the mode phase. The experimental and the finite element analysis results showed that the out-of-phase mode shapes were deviated from the symmetrical mode shapes in the plate transverse direction fur the unequal plate thickness case.

엔터테인먼트용 로봇차량의 제작과 균형 제어 (Implementation and Balancing Control of a Robotic Vehicle for Entertainment)

  • 김현욱;조성택;정슬
    • 제어로봇시스템학회논문지
    • /
    • 제20권7호
    • /
    • pp.736-740
    • /
    • 2014
  • This paper presents the driving and balancing control of an entertainment robot vehicle that can carry two persons. The entertainment robot vehicle is built with the purpose of carrying passengers with two wheels. It has two driving modes: a balancing mode with two wheels and a driving mode with three wheels. Three cases of different modes are verified by experimental studies. Firstly, a driving mode is tested with two passengers to check the functionality of the vehicle. Secondly, the balancing control performance is tested. Lastly, the balancing control performance under the disturbance is tested.

구분모드합성법과 부분구조합성법의 비교 (Comparison of Component Mode Synthesis and Substructure Synthesis Methods)

  • 곽문규;나성수;배병찬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1348-1353
    • /
    • 2006
  • This paper is concerned with the comparison of component mode synthesis md substructure synthesis methods. Those two methods were developed for the dynamic analysis of complex structure. However, the difference between two methods in solving the dynamic problem has never been explained. In this paper, a structure consisting of two beams is considered for the application of two methods. The dynamic formulation shows the characteristics and differences of two methods. The procedure for choosing proper substructure modes in each method is explained in detail. In addition, the advantage of the substructure synthesis method is discussed based on the numerical example. Numerical examples show how two methods are applied to the addressed problem.

  • PDF

Ablative Outcomes of Various Energy Modes for No-Touch and Peripheral Tumor-Puncturing Radiofrequency Ablation: An Ex Vivo Simulation Study

  • Dong Ik Cha;Min Woo Lee;Kyoung Doo Song;Seong Eun Ko;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.189-201
    • /
    • 2022
  • Objective: To compare the outcomes of radiofrequency ablation (RFA) using dual switching monopolar (DSM), switching bipolar (SB), and combined DSM + SB modes at two different interelectrode distances (25 and 20 mm) in an ex vivo study, which simulated ablation of a 2.5-cm virtual hepatic tumor. Materials and Methods: A total of 132 ablation zones were created (22 ablation zones for each protocol) using three separable clustered electrodes. The performances of the DSM, SB, and combined DSM + SB ablation modes were compared by evaluating the following parameters of the RFA zones at two interelectrode distances: shape (circularity), size (diameter and volume), peritumoral ablative margins, and percentages of the white zone at the midpoint of the two electrodes (ablative margin at midpoint, AMm) and in the electrode path (ablative margin at electrode path, AMe). Results: At both distances, circularity was the highest in the SB mode, followed by the DSM + SB mode, and was the lowest in the DSM mode. The circularity of the ablation zone showed a significant difference among the three energy groups (p < 0.001 and p = 0.002 for 25-mm and 20-mm, respectively). All size measurements, AMm, and AMe were the greatest in the DSM mode, followed by the DSM + SB mode, and the lowest were with the SB mode (all statistically significant). The white zone proportion in AMm and AMe were the greatest in the SB mode, followed by the DSM + SB mode and DSM in general. Conclusion: DSM and SB appear to be complementary in creating an ideal ablation zone. RFA with the SB mode can efficiently eradicate tumors and create a circular ablation zone, while DSM is required to create a sufficient ablative margin and a large ablation zone.

미끄럼 속도변화에 따른 철강재료의 미끄럼 마모거동 (중마모 거동에 미치는 연마모 도입시험의 영향) (Sliding Wear Behavior of Carbon Steel in changing Sliding Speed (Effects of Mild Wear Mode Test on subsequent Severe Wear Behavior))

  • 이한영
    • Tribology and Lubricants
    • /
    • 제36권3호
    • /
    • pp.117-123
    • /
    • 2020
  • In this study, the effect of the pre-mild wear mode test condition on the subsequent severe wear behavior of carbon steel has been investigated when the wear mode is varied according to the sliding speed change during sliding contact. Two sliding speeds of 0.3 m/s and 3 m/s for the mild wear mode test have been chosen and a sliding speed of 1 m/s for the severe wear mode test. A mild wear mode test at two different sliding speeds has been carried out during the severe wear mode test and total sliding distance of the mild wear mode test has been changed at this time. As a result, it could be found that the wear rate of carbon steel under the severe wear mode test after performing a pre-mild wear mode test is significantly reduced, compared with that before performing. However, its wear rate was slightly higher than that under the mild wear mode test. Oxides produced during the pre-mild wear mode test have been found to play a significant role in reducing the wear rate under the subsequent severe wear mode test. In particular, it was found that the effect of a pre-mild wear mode test performed at the sliding speed of 3 m/s has more rapid and the reduction in the wear rate was greater than thst at the sliding speed of 0.3 m/s.

Two-Resonance Mode 방법용으로 제작된 고온초전도 평행판 사파이어 공진기의 마이크로파 특성 (Microwave Properties of HTS Parallel-Plate Sapphire Resonators Designed for the Two-Resonance Mode Method)

  • 정호상;양우일;이재훈;이상영
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.106-111
    • /
    • 2010
  • Sapphire resonators with $YBa_2Cu_3O_{7-\delta}$ (YBCO) endplates have provided a way to realize extremely high quality factor due to the extremely low dielectric loss of sapphire and conductive loss of YBCO films, which enables to measure the low surface resistance of superconductor films at microwave frequencies. We present microwave properties of HTS sapphire resonators designed for measuring the surface resistance of HTS films at millimeter-wave frequencies by using the two-resonance mode dielectric resonator method. Despite enhanced surface resistance ($R_S$) of YBCO films due to the quadratic frequency dependence of the $R_S$, the unloaded quality factor ($Q_0$) of the $TE_{021}$ mode sapphire resonator still appears to be well above $1\;{\times}\;10^6$ at a mm-wave frequency of 38 GHz at 10 K. However, it appears that the $TE_{012}$ mode $Q_0$ is unexpectedly low despite that the corresponding resonance peak looks uncoupled with parasitic modes. We discuss possible reasons for the unexpected results using the surface resistance at the $TE_{021}$, $TE_{012}$, and $TE_{011}$ mode frequencies.

Free vibrations of a two-cable network inter-supported by cross-links extended to ground

  • Zhou, H.J.;Wu, Y.H.;Li, L.X.;Sun, L.M.;Xing, F.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.653-667
    • /
    • 2019
  • Using cross-ties to connect cables together when forming a cable network is regarded as an efficient method of mitigating cable vibrations. Cross-ties have been extended and fixed on bridge decks or towers in some engineering applications. However, the dynamics of this kind of system need to be further studied, and the effects of extending cross-links to bridge decks/towers on the modal response of the system should be assessed in detail. In this paper, a system of two cables connected by an inter-supported cross-link with another lower cross-link extended to the ground is proposed and analyzed. The characteristic equation of the system is derived, and some limiting solutions in closed form of the system are derived. Roots of cable system with special configurations are also discussed, attention being given to the case when the two cables are identical. A predictable mode behavior was found when the stiffness of inter-connection cross-link and the cross-link extended to the ground were the same. The vector of mode energy distribution and the degree of mode localization index are proposed so as to distinguish global and local modes. The change of mode behaviors is further discussed in the case when the two cables are not identical. Effects of cross-link stiffness, cross-link location, mass-tension ratio, cable length ratio and frequency ratio on $1^{st}$ mode frequency and mode shape are addressed.

태양광 발전의 효율 향상을 위한 이중모드 추적 시스템 제어 (Two-mode tracking system control of PV generation for efficiency improvement)

  • 장미금;고재섭;최정식;백정우;강성준;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1082_1083
    • /
    • 2009
  • This paper proposes two-mode tracking system control algorithm to improve efficiency of PV system. Two-mode control algorithm tracks sun position using sensor method and program method with insolation condition. Also, in this case that insolation is very low, tracking system is controlled by environment mode to reduce the power loss. Proposed algorithm is applied the PV system and analyzes the generation value. And this algorithm proves the validity of this paper through the experimental result.

  • PDF

Mode localization and veering of natural frequency loci in two circular plates coupled with a fluid

  • Jeong, Kyeong-Hoon
    • Structural Engineering and Mechanics
    • /
    • 제22권6호
    • /
    • pp.719-739
    • /
    • 2006
  • An analytical method for the free vibration of two circular plates coupled with an inviscid and compressible fluid is developed by the Rayleigh-Ritz method. The fluid is bounded by a rigid cylindrical vessel and two circular plates with an unequal thickness and diameter. It was found that the theoretical results could predict well the fluid-coupled natural frequencies with an excellent accuracy when compared with the finite element analysis results. As the fluid thickness increases or the plate thickness difference increases, an abrupt curve veering in the natural frequency loci of the neighboring modes and drastic changes in the corresponding mode shapes are observed. The mode localization frequently appears in the higher modes and in the wide gap between the plates because of a decrease in the fluid coupling owing to the fluid dispersion effect.