• 제목/요약/키워드: two-dimensional beam

검색결과 564건 처리시간 0.028초

Three-dimensional finite element analysis of unilateral mastication in malocclusion cases using cone-beam computed tomography and a motion capture system

  • Yang, Hun-Mu;Cha, Jung-Yul;Hong, Ki-Seok;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.96-106
    • /
    • 2016
  • Purpose: Stress distribution and mandible distortion during lateral movements are known to be closely linked to bruxism, dental implant placement, and temporomandibular joint disorder. The present study was performed to determine stress distribution and distortion patterns of the mandible during lateral movements in Class I, II, and III relationships. Methods: Five Korean volunteers (one normal, two Class II, and two Class III occlusion cases) were selected. Finite element (FE) modeling was performed using information from cone-beam computed tomographic (CBCT) scans of the subjects' skulls, scanned images of dental casts, and incisor movement captured by an optical motion-capture system. Results: In the Class I and II cases, maximum stress load occurred at the condyle of the balancing side, but, in the Class III cases, the maximum stress was loaded on the condyle of the working side. Maximum distortion was observed on the menton at the midline in every case, regardless of loading force. The distortion was greatest in Class III cases and smallest in Class II cases. Conclusions: The stress distribution along and accompanying distortion of a mandible seems to be affected by the anteroposterior position of the mandible. Additionally, 3-D modeling of the craniofacial skeleton using CBCT and an optical laser scanner and reproduction of mandibular movement by way of the optical motion-capture technique used in this study are reliable techniques for investigating the masticatory system.

An efficient hybrid TLBO-PSO-ANN for fast damage identification in steel beam structures using IGA

  • Khatir, S.;Khatir, T.;Boutchicha, D.;Le Thanh, C.;Tran-Ngoc, H.;Bui, T.Q.;Capozucca, R.;Abdel-Wahab, M.
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.605-617
    • /
    • 2020
  • The existence of damages in structures causes changes in the physical properties by reducing the modal parameters. In this paper, we develop a two-stages approach based on normalized Modal Strain Energy Damage Indicator (nMSEDI) for quick applications to predict the location of damage. A two-dimensional IsoGeometric Analysis (2D-IGA), Machine Learning Algorithm (MLA) and optimization techniques are combined to create a new tool. In the first stage, we introduce a modified damage identification technique based on frequencies using nMSEDI to locate the potential of damaged elements. In the second stage, after eliminating the healthy elements, the damage index values from nMSEDI are considered as input in the damage quantification algorithm. The hybrid of Teaching-Learning-Based Optimization (TLBO) with Artificial Neural Network (ANN) and Particle Swarm Optimization (PSO) are used along with nMSEDI. The objective of TLBO is to estimate the parameters of PSO-ANN to find a good training based on actual damage and estimated damage. The IGA model is updated using experimental results based on stiffness and mass matrix using the difference between calculated and measured frequencies as objective function. The feasibility and efficiency of nMSEDI-PSO-ANN after finding the best parameters by TLBO are demonstrated through the comparison with nMSEDI-IGA for different scenarios. The result of the analyses indicates that the proposed approach can be used to determine correctly the severity of damage in beam structures.

광 회절계를 이용한 격자 피치 표준 시편의 측정 및 불확도 해석 (Measurement of Grating Pitch Standards using Optical Diffractometry and Uncertainty Analysis)

  • 김종안;김재완;박병천;강주식;엄태봉
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.72-79
    • /
    • 2006
  • We measured grating pitch standards using optical diffractometry and analyzed measurement uncertainty. Grating pitch standards have been used widely as a magnification standard for a scanning electron microscope (SEM) and a scanning probe microscope (SPM). Thus, to establish the meter-traceability in nano-metrology using SPM and SEM, it is important to certify grating pitch standards accurately. The optical diffractometer consists of two laser sources, argon ion laser (488 nm) and He-Cd laser (325 nm), optics to make an incident beam, a precision rotary table and a quadrant photo-diode to detect the position of diffraction beam. The precision rotary table incorporates a calibrated angle encoder, enabling the precise and accurate measurement of diffraction angle. Applying the measured diffraction angle to the grating equation, the mean pitch of grating specimen can be obtained very accurately. The pitch and orthogonality of two-dimensional grating pitch standards were measured, and the measurement uncertainty was analyzed according to the Guide to the Expression of Uncertainty in Measurement. The expanded uncertainties (k = 2) in pitch measurement were less than 0.015 nm and 0.03 nm for the specimen with the nominal pitch of 300 nm and 1000 nm. In the case of orthogonality measurement, the expanded uncertainties were less than $0.006^{\circ}$. In the pitch measurement, the main uncertainty source was the variation of measured pitch values according to the diffraction order. The measurement results show that the optical diffractometry can be used as an effective calibration tool for grating pitch standards.

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

선형 모멘트 하중을 받는 계단식 단면변화 I형보의 비탄성 횡-비틀림 좌굴강도산정을 위한 모멘트 구배계수 연구 (A Study on Moment Gradient Factor for Inelastic Lateral-Torsional Buckling Strength of Stepped I-Beam Subjected to Linear Moment Gradient)

  • 박종섭;손지민
    • 한국방재학회 논문집
    • /
    • 제8권6호
    • /
    • pp.53-60
    • /
    • 2008
  • 일반적으로 연속경간을 가지는 강합성 I-형강 교량에 있어서 내부 지점 부근에서 상대적으로 큰 부모멘트가 발생하므로, 이에 경제적인 단면 활용을 위하여 변단면을 적용하여 휨강도를 증가시킨다. 본 연구에서는 기존 횡-비틀림 좌굴식에 관한 연구를 토대로 하여 비탄성 구간에 있는 계단식 I형보의 횡-비틀림 좌굴강도를 유한요소해석프로그램 ABAQUS(2007)를 이용하여 산정하고, 간편한 설계식을 제안하고 있다. 양단 및 일단 계단식 단면변화를 가지는 보에 대해서 고려하였으며, 플랜지 길이방향 비, 너비방향 비, 두께의 비로 계단식 I형보를 나타내었다. 해석에 사용된 단면매개변수는 각각 27가지 및 36가지 조합이며, 비탄성 횡-비틀림 거동을 고려하기위하여 잔류응력 및 초기결함을 고려한 비선형해석을 실시하였는데, Pi와 Trahair(1995)가 고려한 잔류응력의 형상과 국내 I형강 표준 치수 허용치에 근거하여 부재 길이의 0.1%를 초기제작오차로 고려하였다. 해석모델의 양쪽 끝단에는 모멘트하중을 재하하였다. 개발 제한된 식은 선형 모멘트 하중이 작용할 때 적용가능한 식으로 경제적이고 합리적인 설계에 적극 활용될 수 있을 것이며, 다양한 하중을 받는 계단식 단면 변화보의 비탄성 좌굴강도 연구에 활용될 수 있을 것이다.

Nanomaterials Research Using Quantum Beam Technology

  • Kishimoto, Naoki;Kitazawa, Hideaki;Takeda, Yoshihiko
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 추계학술발표대회
    • /
    • pp.7-7
    • /
    • 2011
  • Quantum beam technology has been expected to develop breakthroughs for nanotechnology during the third basic plan of science and technology (2006~2010). Recently, Green- or Life Innovations has taken over the national interests in the fourth basic science and technology plan (2011~2015). The NIMS (National Institute for Materials Science) has been conducting the corresponding mid-term research plans, as well as other national projects, such as nano-Green project (Global Research for Environment and Energy based on Nanomaterials science). In this lecture, the research trends in Japan and NIMS are firstly reviewed, and the typical achievements are highlighted over key nanotechnology fields. As one of the key nanotechnologies, the quantum beam research in NIMS focused on synchrotron radiation, neutron beams and ion/atom beams, having complementary attributes. The facilities used are SPring-8, nuclear reactor JRR-3, pulsed neutron source J-PARC and ion-laser-combined beams as well as excited atomic beams. Materials studied are typically fuel cell materials, superconducting/magnetic/multi-ferroic materials, quasicrystals, thermoelectric materials, precipitation-hardened steels, nanoparticle-dispersed materials. Here, we introduce a few topics of neutron scattering and ion beam nanofabrication. For neutron powder diffraction, the NIMS has developed multi-purpose pattern fitting software, post RIETAN2000. An ionic conductor, doped Pr2NiO4, which is a candidate for fuel-cell material, was analyzed by neutron powder diffraction with the software developed. The nuclear-density distribution derived revealed the two-dimensional network of the diffusion paths of oxygen ions at high temperatures. Using the high sensitivity of neutron beams for light elements, hydrogen states in a precipitation-strengthened steel were successfully evaluated. The small-angle neutron scattering (SANS) demonstrated the sensitive detection of hydrogen atoms trapped at the interfaces of nano-sized NbC. This result provides evidence for hydrogen embrittlement due to trapped hydrogen at precipitates. The ion beam technology can give novel functionality on a nano-scale and is targeting applications in plasmonics, ultra-fast optical communications, high-density recording and bio-patterning. The technologies developed are an ion-and-laser combined irradiation method for spatial control of nanoparticles, and a nano-masked ion irradiation method for patterning. Furthermore, we succeeded in implanting a wide-area nanopattern using nano-masks of anodic porous alumina. The patterning of ion implantation will be further applied for controlling protein adhesivity of biopolymers. It has thus been demonstrated that the quantum beam-based nanotechnology will lead the innovations both for nano-characterization and nano-fabrication.

  • PDF

양성자치료용 보상체의 영상기반 정도 관리 기반 프로그램 개발 (Image Based Quality Assurance of Range Compensator for Proton Beam Therapy)

  • 김진성;윤명근;김동욱;임영경;곽정원;박소아;신동호;신정욱;이세병;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.35-41
    • /
    • 2008
  • 양성자치료는 양성자의 물리적 특성으로 인해 인체 내의 특정범위에 모든 에너지를 전달하고 감쇠되어 타겟조직 뒤에 존재하는 정상조직에는 방사선이 조사되지 않는 큰 장점을 가진 치료법이다. 이 방법은 인체 내의 암 조직을 타겟으로 했을 때, 빔 방향에서의 타겟의 2차원적인 모양은 황동으로 제작된 블럭을 통해 정상조직에 들어가는 방사선을 차폐하고 마진을 주어서 GTV (eross Tumor Volume)에 90% 이상의 선량이 전달되도록 조절한다. 그리고, 양성자 빔의 날줄방향 (longitudinal)에서의 타겟의 3차원적인 모양을 고려하여 PMMA로 이루어진 보상체(compensator)를 밀링머신으로 조각하여 타겟에 방사선이 정확하게 분포되도록 한다. 이러한 보상체의 정확한 정도 관리를 위해 현재 사용되는 수동적인 방법을 보완하여 X선 영상으로 해당하는 보상체의 영상을 획득하여 이 영상을 기반으로 정도관리를 할 수 있는 방법을 제안하였고, 제안한 방법으로 보상체의 각각의 깎여진 평면의 모양과 두께를 정성적으로 비교 및 평가할 수 있었으며 두 영상의 차이가 80% 이상 맞는 것으로 확인되었다. 이를 바탕으로 영상을 이용한 정도관리 프로그램을 보완하여 추후 실제 양성자치료 정도관리에 사용될 예정이다.

  • PDF

3차원입체조형방사선치료 계획 시 간종괴의 위치에 따른 최적 조사 방향의 결정 (Optimal Radiation Port Arrangements for Hepatic Tumor using 3-dimensional Conformal Radiotherapy Planning)

  • 이익재;성진실;심수정;정경근;조광환
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.187-195
    • /
    • 2006
  • 본 연구는 간암 환자의 방사선치료 시에 정상 조직과 간암의 위치에 따른 적절한 조사방향을 찾고자 하였다. 간암의 위치는 Couinaud에 의한 분류법을 이용하여 4군으로 나누었고, 각 군의 용적을 가상의 표적 용적으로 정해서 여러 개의 방사선 치료계획을 세워 정상조직합병증발생률(normal tissue complication probability, NTCP)을 비교하였다. 그룹 I에서는 조사 수를 늘릴수록 정상간의 NTCP가 감소되었으나 6개 이상부터는 일정하였다. 그룹 II에서는 PA(posterior to anterior) 조사가 추가 되었을 때 정상간의 NTCP가 증가하였다. 그룹 III는 표적용적 주변에 정상조직이 많아 조사 방향의 설정에 어려움이 있었고 여러 방향에서의 조사 보다는 RAO(right anterior oblique)와 PA를 이용한 2개의 조사만이 시행되었을 때 정상 간의 NTCP가 가장 낮았다. 그룹 IV에서도 RAO와 PA의 2개 조사로 이루어진 치료계획에서 정상 간의 NTCP 가 가장 낮았다. 본 연구를 통해 간암의 방사선 치료계획 시 간암의 위치와 정상조직의 위치에 따라 NTCP 가 다양하게 나타남을 알 수 있었고, 간암의 방사선치료 계획 시 최적 조사 방향의 설정을 통해 임상적으로 방사선치료를 적용하는 데 유용한 지침이 될 수 있을 것으로 생각된다.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method

  • Nabil M. Mansour;Mohamed E. Abdelshaheed;Ahmed H. El-Sabbagh;Ahmed M. Bahaa El-Din;Young Chul Kim;Jong-Woo Choi
    • Archives of Plastic Surgery
    • /
    • 제50권3호
    • /
    • pp.254-263
    • /
    • 2023
  • Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations: 0.18 mm; mean angular variations: 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.