• Title/Summary/Keyword: turn signal operation

Search Result 60, Processing Time 0.023 seconds

Design of Domestic Induction Cooker based on Optimal Operation Class-E Inverter with Parallel Load Network under Large-Signal Excitation

  • Charoenwiangnuea, Patipong;Ekkaravarodome, Chainarin;Boonyaroonate, Itsda;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.892-904
    • /
    • 2017
  • A design of a Class-E inverter with only one inductor and one capacitor is presented. It is operated at the optimal operation mode for domestic cooker. The design principle is based on the zero-voltage derivative switching (ZVDS) of the Class-E inverter with a parallel load network, which is a parallel resonant equivalent circuit. An induction load characterization is obtained from a large-signal excitation test bench, which is the key to an accurate design of the induction cooker system. Consequently, the proposed scheme provides a more systematic, simple, accurate, and feasible solution than the conventional quasi-resonant inverter analysis based on series load network methodology. The derivative of the switch voltage is zero at the turn-on transition, and its absolute value is relatively small at the turn-off transition. Switching losses and noise are reduced. The parameters of the ZVDS Class-E inverter for the domestic induction cooker must be selected properly, and details of the design of the components of this Class-E inverter need to be addressed. A 1,200 W prototype is designed and evaluated to verify the validation of the proposed topology.

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.

Signal subspace comparison between Physical & synthesized array data in echo imaging

  • Choi, Jeong-Hee
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.262-267
    • /
    • 1998
  • In Synthetic Aperture Radar(SAR) imaging, the echoed data are collected by moving radar's position with respect to the target area, and this operation actually gives effect of synthesizing aperture size, which in turn gives better cross range resolution of reconstructed target scene. Among several inversion scheme for SAR Imaging, we uses an inversion scheme which uses no approximation in wave propagation analysis, and try to verify whether the collected data with synthesized aperture actually gives the same support as that with physical aperture in the same size. To do this, we make a signal subspace comparison of two imaging models with physical and synthesized arrays, respectively. Theoretical comparison and numerical analysis using Gram-Schmidt procedures had been performed. The results showed that the synthesized array data fully span the physical array data with the same system geometry and strongly support the proposed inversion scheme valuable in high resolution radar imaging.

  • PDF

Development of Gap Acceptance Models for Permitted Left Turn Intersections during Rainfall (우천시 비보호좌회전에서의 간격수락 행태모형 개발)

  • Hwang, Soon Cheon;Lee, Chungwon;Lee, Dong Min
    • International Journal of Highway Engineering
    • /
    • v.19 no.4
    • /
    • pp.61-68
    • /
    • 2017
  • PURPOSES : A complete signal system is not always the best solution for improving traffic operation efficiency at intersections. An alternative solution is to use a Protected Permitted Left Turn (PPLT) operation method. However, the PPLT method needs to be developed after a detailed study of driving tendencies, most notably the gap acceptance behavior, for successful implementation. In this study, the gap acceptance behavior was investigated under various variables and weather conditions, especially under rain, and the results were compared to the case of normal weather. The results of this study will be helpful in introducing the PPLT method, and are important considering the tendency of attempting unprotected left turns that is extremely common in Korean drivers. METHODS : Data was obtained by analyzing traffic footage at four intersections on a day when the precipitation was greater than 5 mm/h. The collected data was classified into seven variables for statistical analysis. Finally, we used logistic regression analysis to develop a probability distribution model. RESULTS : Gap, traffic volume, and the number of conflicting lanes were factors affecting the gap acceptance behavior of unprotected left turns under rainy conditions. CONCLUSIONS : The probability of attempting unprotected left turns is higher for larger gaps. On the other hand, the probability of attempting unprotected left turns decreases with an increase in the traffic volume. Finally, an increase in the number of conflict lanes leads to a decrease in the probability of attempting unprotected left turns.

A Study of Memory Device based on Tunneling Mechanism (터널링 메커니즘을 이용한 메모리 소자 연구)

  • Lee Jun-Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.17-20
    • /
    • 2006
  • This paper presents of a new type of memory cell that could potentially replace both DRAM and flash memory. The proposed device cell operates by sensing the state of about 1,000 electrons trapped between unique insulating barriers in the channel region of the upper transistor. These electrons are controlled by a side gate on the transistor, and their state in turn controls the gate of the larger transistor, providing signal gain within the memory cell. It becomes faster and more reliable memory with lower operation voltage. Moreover, the use of a multiple tunnel junction (MTJ) fur the vertical transistor can significantly improve the data retention and operation speed.

  • PDF

Development of a Traffic Signal Controller for the Tri-light Traffic Signal (3구신호등 제어용 교통신호제어기 개발)

  • Han, Won-Sub;Gho, Gwang-Yong;Heo, Nak-Won;Lee, Chul-Kee;Ha, Dong-Ik;Lee, Byung-Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.49-58
    • /
    • 2010
  • The traffic signal controllers being used in the domestic currently are being manufactured based on the korean national police standard which was developed for controlling the quad-light traffic signal having the red, yellow, left-turn arrow, and green lights. But according to the national policy for the traffic operation, they have to be changed to be able to switch the tri-light signal having red, yellow and green lights. In this study, a new tri-light traffic signal controller was designed and developed by the way improving the Signal Control Unit of the existing quad-light standard traffic controller. The Load Signal Unit(LSU) was improved to output 6 signals which are the two assemblies of three signal indications having the red, yellow, and green lights. To enough traffic signals output to control each directional movements and the various transport modes which are car, bus, bike, and pedestrian etc., the connector bus system was designed to be able to accommodate maximum 96 signals outputs being constructed by 16 LSUs. Flasher device was developed to be able to support maximum 32 red signals. In the software, the communication protocol between traffic control center and the traffic signal controller was improved and new signal map code values were defined for the developed LSU controlling the quad-light traffic signal. A model of the quad-light traffic signal controller developed and was tested three operations, protocol-operation, remote-command and control-mode. The test result operated all of them successfully.

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

Advanced Algorithm for IED of Stator Winding Protection of Generator System (발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.

A Comparative Study on the Accident Characteristics of the Elderly According to the Urban-Rural Complex Area and Regional Types (도농복합지역과 지역유형에 따른 노인교통사고 특성 비교연구)

  • Kim, Kyung-Bum;Hwang, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.224-236
    • /
    • 2017
  • This study analyzed the characteristics of traffic accidents among elderly drivers according to area type in Gyeonggido(urban areas, urban-rural complex areas, and rural areas). Traffic accidents caused by unsafe driving are common in all three types of areas. In urban areas and urban-rural complex areas, traffic accidents were more frequent due to traffic violations and intersection accidents, while rural areas were more affected by central lines. Urban areas and urban-rural complex areas require simpler signal exposures, such as a simple straight line, left turn, or straight line and left turn signal rather than complex signal operations, such as overlaps in a signal operation. Improvement of non-signal intersections and unprotected traffic signal processing is also needed. In order to prevent the intrusion of the central line in rural areas, the center line guard rail should be prevented from penetrating the center line, and the influence of the vehicle headlamp should be reduced in the opposite direction. It is necessary to improve the visibility by using fluorescent letters to enlarge the font size of traffic signs and road signs, particularly to increase visibility at night and prevent traffic accidents at sunset. Minimal, simplified should be provided rather than complex phrases and information.

A Study on Functionality Evaluation Method of Real-time Traffic Signal Control System (실시간 신호제어시스템 기능성 평가방법론에 관한 연구)

  • Lee, Choul-Ki;Oh, Young-Tae;Lee, Hwan-Pil;Yang, Ryun-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.1
    • /
    • pp.42-58
    • /
    • 2008
  • Nowadays the installation of Real-time Traffic Signal Control system is gradually spread, in order to solve the traffic problem which become serious. The most important thing are reliability of data collection and functionality of system in Real-time Traffic Signal Control System. But, the evaluation for those introduction system are defective after system constructing. So, many systems are not working properly to those systems's primarily purpose. This study is executed expansion through field test and analysis which check performance and advise of system operation. It has purpose to establish of the maintenance system of Real-time Traffic Signal Control system. As the result of analysis, we could find the several problems in this study. So, we also could guess that the effective maintenance systems of the Real-time Traffic Signal Control system is necessary within few years.

  • PDF