• Title/Summary/Keyword: turbo-machinery

Search Result 172, Processing Time 0.035 seconds

Fan Performance Test with Automatic Control and Measurement (자동제어계측을 이용한 송풍기 성능시험)

  • Choi, Young-Seok;Kim, Jin-Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

Predictions of Unbalanced Response of Turbo Compressor Equipped with Active Magnetic Bearings through System Identification (시스템 식별을 통한 자기베어링 장착 터보 압축기의 불평형 응답 예측)

  • Baek, Seongiki;Noh, Myounggyu;Lee, Kiwook;Park, Young-Woo;Lee, Nam Soo;Jeong, Jinhee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.97-102
    • /
    • 2016
  • Since vibrations in rotating machinery is a direct cause of performance degradation and failures, it is very important to predict the level of vibrations as well as have a method to lower the vibrations to an acceptable level. However, the changes in balancing during installation and the vibrational modes of the support structure are difficult to predict. This paper presents a method for predicting the unbalanced response of a turbo-compressor supported by active magnetic bearings (AMBs). Transfer functions of the rotor are obtained through system identification using AMBs. These transfer functions contain not only the dynamics of the rotor but also the vibrational modes of the support structure. Using these transfer functions, the unbalanced response is calculated and compared with the run-up data obtained from a compressor prototype. The predictions revealed the effects of the support structure, validating the efficacy of the method.

A Study of Aerodynamic Design of a Radial Turbine for BOP of MCFC Fuel Cell System (연료전지 BOP용 구심터빈 공력설계에 관한 연구)

  • Choi, Bum-Seog;Ahn, Kook-Young;Park, Moo-Ryong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.531-534
    • /
    • 2006
  • This study is concerned with radial turbine design and performance improvement of a turbo generator system, which is used for maximizing performance of a 250kW MCFC fuel cell system. A preliminary design of a radial turbine has been performed under the thermodynamic and fluid-dynamic conditions determined by a cycle analysis of the MCFC BOP system. Basic demensions are determined by a meanline analysis and calculation of radial variation at the exit of the turbine. The turbine impeller is designed and modified by iterative processes of three dimensional flow analysis.

  • PDF

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.

The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire (터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구)

  • Yang, Sang-Ho;Choi, Young-Seok;Kim, Jung-Yup;Kim, Nam-Goo;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

Effects of the Geometry of Components Attached to the Drain Valve on the Performance of Water Hammer Pumps

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi;Dejima, Keita
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.4
    • /
    • pp.367-374
    • /
    • 2011
  • Water hammer pumps can effectively use the water hammer phenomenon in long-distance pipeline networks that include pumps and allow fluid transport without drive sources, such as electric motors. The results of experiments that examined the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. In addition, a paper has also been published analyzing the water hammer phenomenon numerically by using the characteristic curve method for comparison with experimental results. However, these conventional studies have not fully evaluated the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. Therefore, as a first stage for the understanding of water hammer pump performance in comparison with the characteristics of typical turbo pumps, the previous paper experimentally examined how the hydrodynamic characteristics were affected by the inner diameter ratio of the drive and lifting pipes, the form of the air chamber, and the angle of the drive pipe. To understand the behavior of the components attached to the valve chamber and the air chamber that affects the performance of water hammer pumps, the previous study also determined the relationship between the water hammer pump performance and temporal changes in valve chamber and air chamber pressures according to the air chamber capacity. For the geometry of components attached to the drain valve, which is another major component of water hammer pumps, this study experimentally examines how the water hammer pump performance is affected by the length of the spring and the angle of the drain pipe.

Counter-Rotating Type Pumping Unit (Impeller Speeds in Smart Control)

  • Kanemoto, Toshiaki;Komaki, Keiichi;Katayama, Masaaki;Fujimura, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.334-340
    • /
    • 2011
  • Turbo-pumps have weak points, such as the pumping operation is unstable on the positive slope of the head curve and/or the cavitation occurs at the low suction head. To improve simultaneously both weak points, the first author invented the unique pumping unit composed of the tandem impellers and the peculiar motor with the double rotational armatures. The front and the rear impellers are driven by the inner and the outer armatures of the motor, respectively. Both impeller speeds are automatically and smartly adjusted in response to the pumping discharge, while the rotational torques between both impellers/armatures are counter-balanced. Such speeds contribute to suppress successfully not only the unstable operation at the low discharge but also the cavitation at the high discharge, as verified with the axial flow type pumping unit in the previous paper. Continuously, this paper investigates experimentally the effects of the tandem impeller profiles on the pump performances and the rotational speeds against the discharge, using the impellers whose loads are low and/or high at the normal discharge. The worthy remarks are that (a) the unstable operation is suppressed as expected and the shut off power is scarcely large in the smart control, (b) the blade profile contributes to determine the discharge giving the maximum/minimum rotational speed where the reverse flow may incipiently appears at the front impeller inlet, (c) the tandem impeller profiles scarcely affect the rotational speeds, while the loads of the front and the rear impellers are same, but (d) the impeller with the low load must run faster and the impeller with the high load must run slower at the same discharge to take the same rotational torque, and (e) the reverse flow at the inlet and the swirling velocity component at the outlet of the front impeller with the high load require making the rotational speed of the rear impeller with low load fairly faster at the lower discharge.

A Study on the Noise Emission Characteristics of Turbo Axial Flow Fan by Experimental Method (터보형송풍기의 소음 방사특성에 관한 실험적 연구)

  • 김동규;백종진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.271-277
    • /
    • 2003
  • Recently as the environmental noise getting influential social problem, it is the fact that the demand on noise reduction increases with the advance of the standard of living. Therefore increasing the interest on the noise in common, it is eagerly demanded that the endeavour for reducing the noise of the rotating machinery, especially the machinery related a flowing including the household electric products, which is pointed out the primary noise source in environment. As proceeding study for fan noise, theory of fan noise property is arranged and this control method is shown. Blade passage noise of total noise spectrum. Thus in the aspect of noise reduction, noise source and identification of noise radiation characteristics of axial flow fan are demanded in detail. The sound source is analyzed by using sound pressure and sound intensity. In that time, synchronization of axial flow fan using optical sensor is executed, and to identify the location of exact noise source in the fan profile determination of recording time is proposed. In the rotating of tan, it is explained that the location of noise source exists in and by the directivity, the noise radiation pattern of axial flow fan is determined and the flow of sound is visualized in the figure of contour mapping.

  • PDF

Experimental Study on the Emission Characteristics of Diesel, GTL, and their Blends with Biodiesel in a Diesel Engine (디젤엔진에서 디젤, GTL, 바이오디젤의 혼합유의 배기배출물 특성에 관한 실험적 연구)

  • Lee, Yong-Gyu;Moon, Gun-Feel;Jeong, Dong-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.140-146
    • /
    • 2010
  • An experimental study was carried out to investigate the emission characteristics for various alternative fuels in a 2.0 liter 4-cylinder turbo-charged diesel engine. The conventional diesel fuel, neat GTL (Gas to Liquid), blends of diesel and biodiesel(BD20), and blends of GTL and biodiesel(G+BD20 and G+BD40) were applied, and their emission characteristics were compared at various steady-state engine operating conditions. A noticeable reduction of exhaust emissions compared to conventional diesel fuel, except for NOx emission, was observed for G+BD40, where there is a maximum 30% averaged reduction for gaseous emissions (THC and CO) and 70% for PM mass concentrations. When comparing PM size distributions for biodiesel blended fuels, the PM number concentration in accumulation mode, where the diameter of PM is greater than 50 nm, decreased due to additional oxygen content in the biodiesel fuel; in nucleation mode, where the diameter of PM is less than 50nm, there was a slight increase or decrease in the PM number concentration depending on the amount of oxygen available in the combustion chamber.

A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery (고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구)

  • Lee, Yong-Bok;Kim, Tae-Ho;Kim, Chang-Ho;Lee, Nam-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.199-206
    • /
    • 2002
  • This paper describes a reliability characteristics of an air foil journal bearing for high speed turbomachinery at room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with motor driven test rig. Lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About load carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, The trends in change of start torque, stop torque, and bearing temperature were shown during 10,000 cycle start-stop test of an air foil journal bearing. from the results of this work, an air foil bearing will be done well, as a supported bearing for high speed turbo-compressor.

  • PDF