• 제목/요약/키워드: turbidity water

검색결과 1,144건 처리시간 0.027초

섬모상 매트에 의한 탁수이동차단에 관한 실험적 연구 (Control of Turbid Water Transport with Filamentous Mat)

  • 유지앙화;이치타오;김영철
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.44-51
    • /
    • 2010
  • A lab-scale apparatus for turbid water transport control was tested and examined. The channel had a dimension of $100cm{\times}30cm{\times}15cm$ (length${\times}$hight${\times}$width). And the turbidity water was prepared using two types of particles, bentonite and loess. The channel equipped with filamentous mat was operated under various shock load conditions. In the control channel, instantly, turbid water mixed with the clean water inside the channel and turbidity prevails the entire channel. While in the mat-equipped channel, it increases only at the bottom. Overall, the filamentous mat gave capture efficiency of 70~90% compared with the control group. The capture efficiency of turbid particles decreased with increased input turbidity flux. The result of experimental run on how turbid particles are separated in the mat channel shows that settling, filtration and attachment are the main processes. Meanwhile, turbidity was diffused from the channel bottom due to turbidity gradient before and after mat zone. The particle size before mat zone was lightly coarser than that after mat zone.

Spectral Characteristics of Shallow Turbid Water near the Shoreline on Inter-tidal Flat

  • Lee, Kyu-Sung;Kim, Tae-Hoon;Yun, Yeo-Sang;Shin, Sang-Min
    • 대한원격탐사학회지
    • /
    • 제17권2호
    • /
    • pp.131-139
    • /
    • 2001
  • Extraction of waterline in tidal flat has been one of the main concerns in the remote sensing of coastal region. This study aimed to define the spectral characteristics of turbid water near the shoreline and to find the appropriate spectrum to delineate the waterline at the inter-tidal flat in the western coast of Korean Peninsula. Spectral reflectance curves were obtained by the field measurements under the diverse condition of water depth and turbidity at the study area in Kyong-gi Bay. Spectroscopy measurements showed that reflectances of the exposed mudflat, shallow turbid water, and normal coastal water were significantly different by wavelength. Shallow water near the waterline showed diverse conditions of turbidity. Spectral reflectance tends to increase as turbidity increases, particularly at the visible and near infrared spectrum. At the middle infrared wavelength, tidal water showed very little reflectance regardless of the turbidity and water depth and was easily disting from the exposed tidal flat. The exact waterline between exposed tidal flat and seawater should be extracted from the image data obtained at the middle infrared wavelength.

Development of a Decision Support System for Turbid Water Management through Joint Dam Operation

  • Kim, Jeong-Kon;Ko, Ick-Hwan;Yoo, Yang-Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.31-39
    • /
    • 2007
  • In this study we developed a turbidity management system to support the operation for effective turbid water management. The decision-making system includes various models for prediction of turbid water inflow, effective reservoir operation using the selective withdrawal facility, analysis of turbid water discharge in the downstream. The system is supported by the intensive monitoring devices installed in the upstream rivers, reservoirs, and downstream rivers. SWAT and HSPF models were constructed to predict turbid water flows in the Imha and Andong catchments. CE-QUAL-W2 models were constructed for turbid water behavior prediction, and various analyses were conducted to examine the effects of the selective withdrawal operation for efficient high turbid water discharge, turbid water distribution under differing amount and locations of turbid water discharge. A 1-dimensional dynamic water quality model was built using Ko-Riv1 for simulation of turbidity propagation in the downstream of the reservoirs, and 2-dimensional models were developed to investigate the mixing phenomena of two waters discharged from the Andong and Imha reservoirs with different temperature and turbidity conditions during joint dam operation for reducing the impacts of turbid water.

  • PDF

제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책 (Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province)

  • 김진근
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

상수도관망에서 대수용가의 유량변화에 따른 수압 및 탁도발생 영향평가 (Impact assessment for water pressure and turbidity occurrence by changes in water flow rate of large consumer at water distribution networks)

  • 최두용;김주환;최민아;김도환
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.277-286
    • /
    • 2014
  • Water discolouration and increased turbidity in the local water service distribution network occurred from hydraulic incidents such as drastic changes of flow and pressure at large consumer. Hydraulic incidents impose extra shear stresses on sediment layers in the network, leading to particle resuspension. Therefore, real time measuring instruments were installed for monitoring the variation of water flow, pressure, turbidity and particulates on a hydrant in front of the inlet point of large apartment complex. In this study, it is attempted to establish a more stable water supply plan and to reduce complaints from customers about water quality in a district metering area. To reduce red or black water, the water flow monitoring and control systems are desperately needed in the point of the larger consumers.

북한강 수계 대규모 탁수사상 발생에 의한 댐 저수지의 탁수 영향 분석 (Analyzing the Effect of an Extreme Turbidity Flow Event on the Dam Reservoirs in North Han River Basin)

  • 박형석;정세웅;정선아
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.282-290
    • /
    • 2017
  • A long-term resuspension of small particles, called persistent turbidity, is one of the most important water quality concerns in the dam reservoirs system located in North Han River. Persistent turbidity may incur aesthetic nuisance and harmful effect on the ecosystem health, in addition to elevated water treatment costs for the drinking water supply to the Seoul metropolitan area. These sufferings have been more intensified as the strength and frequency of rainfall events increase by climate change in the basin. This study was to analyze the effect of an extreme turbidity flow event that occurred in 2006 on the serial reservoirs system (Soyang-Uiam-Cheongpyung-Paldang) in North Han River. The CE-QUAL-W2 model was set up and calibrated for the river and reservoirs system using the field data obtained in 2006 and 2007. The results showed that Soyang Reservoir released turbid water, which was classified as the TSS concentration is greater than 25 mg/L, for 334 days with peak TSS of 264.1 mg/L after the extreme flood event (592.7 mm) occurred between July 10 and 18 of 2006. The turbid water departed from Soyang Reservoir reached at the most downstream Paldang Reservoir after about 20 days and sustained for 41 days, which was validated with water treatment plant data. Since the released water from Soyang Reservoir had low water temperature and high TSS, an underflow formed in the downstream reservoirs and vertically mixed at Paldang Reservoir due to dilution by the sufficient inflow from South Han River.

창원시 대산면 강변여과수의 수질과 낙동강 수질의 관련성 연구

  • 장성;함세영;김형수;차용훈;정재열
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.451-454
    • /
    • 2004
  • The study aims to assess the quality of bank filtrate in relation to streamflow and physico-chemical properties of the stream. Turbidity, pH, temperature and dissolved oxygen (DO) of Nakdong River and riverbank filtrate were statistically analyzed. The physico-chemical properties of riverbank filtrate were measured from irregularly different seven pumping wells every day. Autocorrelation analyses were conducted to the qualities of stream water and bank filtrated water. Temperature, pH and DO of streamflow shows strong linearity and long memory effect, indicating the effect of seasonal air temperature and rainy season. Temperature of riverbank filtrate shows weak linearity and weak memory, indicating differently from the trend of stream temperature. Turbidity of steramflow shows strong linearity and long memory effect, while turbidity of riverbank filtrate indicates weak linearity and weak memory. Cross-correlation analysis shows low relation between turbidity, pH, temperature and DO of riverbank filtrate and those of streamflow. Turbidity of streamflow was largely affected by the streamflow rate, showing a similar trend with autocorrelation function of streamflow rate. The turbidity of riverbank filtrate has a lag time of 25 hours. This indicates that turbidity of streamflow in a dry season has very low effect on the turbidity of riverbank filtrate, and a high turbidity of the stream in a rainy season has a fairly low effect on the turbidity of riverbank filtrate.

  • PDF

정수처리시 잔류알루미늄 농도를 최소화하기 위한 영향인자 고찰 (A Study on the Factors to Minimize the Residual Aluminum in Filtered Water)

  • 고영송;우달식;남상호
    • 한국환경보건학회지
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 1993
  • In public water supply systems, Alum and/or PAC being used as a coagulant. It is well known that their use increased frequently the concentration of residual aluminum in filtered water upon operating conditions. This study was conducted to find the optimum conditions that both the concentration of residual aluminum and turbidity are minimized by changing such factors as pH, temperature, alum dosage, mixing rate, alkalinity and hardness. The results can be summarized as follows: The pH values for the minimum concentration of residual aluminum and turbidity as a given experimental condition were found at pH 6 and pH 7 respectively, the apparent clarity was best at pH 8. The floc settling rate was the greatest at pH 6.5, but the turbidity was high at the same condition. The more alum dosage, the higher the concentration of residual aluminum. However the alum dosage less than 15 mg/l tend to decrease in turbidity. Restabilization and enmeshment occurred near 15 mg/l and 20 mg/l of alum dose respectively. With the increase of mixing rate (rapid and slow), the concentration of residual aluminum and turbidity are increased and the same trend was found in increment of mixing time. At low water temperature, the concentration of residual aluminum was decreased, but turbidity was increased. It was confirmed that alkalinity had an effect on the coagulation efficiency, but hardness did not.

  • PDF

천연 제올라이트 활용을 통한 댐 및 호소의 오염수 처리 (Polluted Water Treatment of Dam and Reservoir using Natural Korean Zeolite)

  • 박기호;서진국
    • 한국산업융합학회 논문집
    • /
    • 제8권2호
    • /
    • pp.113-120
    • /
    • 2005
  • Due to the Typhoon MAEMI on Sep. of 12 in 2003, the turbidity value of DOAM Dam was recorded more than 300NTU until now. The natural zeolite located in the east coast of Korean peninsula was applied to reduce turbidity with cation exchange process. The result of this technique, the value of turbidity was reduced less than 1NTU. Also the value of pH showed stable state compare to before and after.

  • PDF

응집침전공정에서 수온, 응집제 종류, 전염소 주입에 따른 크립토스포리 디움과 지아디아 제거 효율 변화에 관한 연구 (The Effects of Temperature, Coagulants, and Pre-chlorination on the Removal of Cryptosporidium and Giardia by Coagulation Process)

  • 박상정;정영희;정현미
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.531-538
    • /
    • 2007
  • The effects of temperature, coagulants and pre-chlorination on the removal of turbidity and pathogenic protozoa by coagulation process were investigated using jar test of lab scale. In room temperature ($25^{\circ}C$), protozoa were removed over 1.0log at the proper concentration range of coagulants, and up to over 2log at the optimal concentration of coagulants. Considering the 1.5log target removal for Giardiain the processes of coagulation, sedimentation, and filtration, this results implies that the target could be satisfied. However, the removal of protozoa and turbidity was reduced, and optimal PAC concentration was narrowed in low turbidity and cold temperature ($5^{\circ}C$). These results suggest that the drop of coagulation efficiency may be occurred in winter if the conditions are not optimized. Despite the effect of water temperature, the relation of turbidity and protozoa removal appeared to be good. The various kinds of coagulants did not significantly affected for removals of turbidity and protozoa when the concentrations of $Al_2O_3$ were considered. Prechlorination did not increase or decrease the removal of turbidity and protozoa in optimum condition at room temperature, pH 7, 15mg/L of PAC concentration.