• Title/Summary/Keyword: turbidity removal

Search Result 329, Processing Time 0.02 seconds

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.

Determination of operating factor and characteristics of membrane fouling on hybrid coagulation pretreatment-UF system in drinking water treatment (정수처리 응집·한외여과 시스템의 연속운전을 통한 운전조건 결정 및 막오염 특성에 관한 연구)

  • Moon, Seong-Yong;Yun, Jong-Sub;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.267-274
    • /
    • 2008
  • This study is about efficiency of pretreatment process and operating factor to membrane process at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06{\beta}(C)/d$. The raw water used was from Nakdong stream which was characteristized by high organic matter and high turbidity. The result of the test was that coagulation is good process as to high removal rate to organic matter and turbidity but It caused problem to membrane pore blocking. This paper is to determine the membrane fouling potential under different membrane flux, backwash pressure and linear velocity. Backwash pressure and flux is important parameter on operation of membrane system. Those are directly affected on membrane system. When backwash pressure increased from 150 kPa to 200 kPa, the result showed that fouling (pressure increase rate) changed from 3.69 kPa/h to 0.93 kPa/h and the recovery rate changed from 90.7 % to 82.0 %. Linear velocity had slightly effect on fouling. Linear velocity increased from 0.2 m/s to 0.5 m/s, the corresponding pressure rate changed from 0.93 kPa/d to 0.77 kPa/d.

A Study on Flux Efficiency on Membrane for Water Reclamination according to Coagulations (하수처리수 재이용을 위한 막분리 공정시 응집조건에 따른 투과효율 변화에 관한 연구)

  • Jung, Jin-Hee;Jang, Sung-Ho;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2011
  • The objectives of this research are to investigate the proper coagulation conditions which are a type and doses of coagulants, mixing conditions (velocity gradients and mixing times), pH and so on through Jar-test, to evaluate the flux variations, permeate, backwashing according to characteristics of pretreatment of the wastewater by means of MF membranes for river maintenance water reuse. The effluent water from B-city K-sewage treatment plant are used for this research. Turbidity and suspended solids(SS) are 14.2 NTU and 10.4 mg/L respectively. This condition causes fouling for membrane process. The flux decline could be reduced when coagulation pretreatment was carried out. Optimal coagulations PAC which are commonly used in the sewage treatment plant was observed in this research. The results indicate that an optimal coagulation dose and pH are 80 ppm and pH of 7 respectively, but coagulation efficiency was lower at strong acid or strong base. Results showed that continuous and steady operations in membrane separation process by means of the effective removal of organic matter and turbidity with coagulation pretreatment of sewage secondary effluent were achieved.

Impact of Characteristics of Polymeric Al Coagulants PACl and Alum on Membrane Flux and Fouling of Microfiltration (PACl 및 Alum 응집제 특성이 정밀여과막 투과수량 및 막오염에 미치는 영향)

  • Jin, Yong-Chul;Choi, Yang-Hun;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.231-240
    • /
    • 2011
  • The objectives of this research are to investigate coagulation efficiencies of two coagulants l.e., alum and polyaluminum chloride and to understand effects of the coagulants on membrane fouling in microfiltration. The turbidity of supernatant from alum coagulation was increased with increasing doses whereas the turbidity from PACl coagulation was maintained at the low values. The observed injection volume of PACl for the same removal was approximately 30 percent less than alum, which produced a low sludge volume. The settling velocity of PACl flocs was greater than alum flocs. The results corresponded well with floc size measurements. Flux decline from alum coagulation was significant due in part to small sizes of flocs. At the low dose, alum floc had less specific cake resistance than PACl floc. However, as the dosage was increased, the increases in specific cake resistances of alum was substantial. Alum coagulation pretreatment needs careful operation to reduce membrane fouling by flocs. In general, PACl coagulants were more effective than alum coagulants for pretreatment of membrane processes because PACl showed the better performance in coagulation and membrane fouling.

A Study on the Flow Fields of Bubble Trap of Turbidimeter Using the Multiphase Model (다상모델을 이용한 탁도계 버블트랩 내부 유동장에 관한 고찰)

  • Lee, Kye-Bock;Kim, Young-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.11
    • /
    • pp.963-970
    • /
    • 2007
  • The objectives of this study are to examine a bubble trap mechanism of the turbidimeter for low turbidity and to acquire it's technology concerned. Reynolds-Averaged Wavier-Stokes equation and Laglangian discrete phase model were applied to analyze a flow field in the bubble trap. 3D hybrid grid system was used to simulate the flow field of bubble trap and numbers of it's node point are about 110,000. From the comparison between the standard $k-{\varepsilon}$ model and the laminar state, it was found that the former estimated less the velocity in the outlet of bubble trap than the latter did, and that the former estimated more the shear stress at the wall of bubble trap than the latter did. And, it was possible to visualize the path of bubbles in the bubble trap and to copy the removal process of bubbles out bubble trap. Also, it was found that nearly most of bubbles in the bubble trap disappeared.

Stochastic Properties of Water Quality Variation in Downstream Part of Han River (한강 하류부의 수질변동에 대한 추계학적 특성(I) - 특히 뚝도 및 노량진 지점의 DO, 탁도, 수온의 변동을 중심으로 -)

  • 이홍근
    • Water for future
    • /
    • v.15 no.3
    • /
    • pp.23-36
    • /
    • 1982
  • The stochastic variations and structures of time series data on water quality were examined by employing the techniques of autocorrelation function, variance spectrum, Fourier series, autoregressive model and ARIMA model. These time series included hourly and daily observation on DO, turbidity, conductivity pH and water temperature. The measurement was made by automatic recording instrument at Noryangjin and Dook-do located in the downstream part of Han River during 1975 and 1976. Hourly water quality time series varied with the dominant 24-hour periodicity, and the 12-hour periodicity was also observed. An important factor affecting 24-hour periodic variation of DO is believed to be photosynthesis by algae. These phenomena might be attributable to periodic discharges of municipal sewage. Noryangjin site showed the more distinct 12-hour periodicity than Dook-do site did, and tidal effect might be responsible for the difference. The water quality, as measured by DO and turbidity, was better in the afternoon compared with the quality in the morning. This change can be explained by the periodic variation of DO, temperature and the amount of municipal wewage discharge. It was also observed that the water temperature at Noryangjin was higher than the temperature at Dook-do. This difference might have been caused by the pollutants that were added to the section between two sites. The correlation coefficients between some of the variables were fairly high. For example, the coefficient was -0.88 between DO and water temperature, 0.75 between turbidity and river flow, and 0.957 between water temperature and air temperature. The lag time of heat transfer from the air to the water was estimated as 24 days. The first order auto-regressive model was appropriate for explaning standardized hourly DO time series. The ARIMA model of (1, 0, 0) type provided relatively satisfactory results for daily DO time series after the removal of significant harmonic value.

  • PDF

Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water (지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지)

  • Park, Byeong-Joo;Do, Si-Hyun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Preparation of Inorganic Coagulants Using Red Mud (적니를 이용한 무기응집제의 제조연구)

  • Kim, Jung-Sik;Lee, Jae-Rok;Han, Sang-Won;Hwang, In-Gook;Bae, Jae-Heum
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2085-2095
    • /
    • 2000
  • Red mud is generated as a by-product during the production of aluminum hydroxide from bauxite ore. In this study inorganic coagulants were prepared by leaching aluminum and iron from red mud with acids under various operating conditions. The optimum leaching efficiency of Al and Fe was obtained by contacting red mud with acids of 5M $H_2SO_4$ and 9M HCI with the ratio of 1/10(g/mL) at $85^{\circ}C$ and $25^{\circ}C$, respectively. In addition. the removal experiments of heavy metal ions($Pb^{2+}$, $Cd^{2+}$, $Cu^{2+}$, $Zn^{2+}$, $Cr^{3+}$), turbidity and phosphate phosphorus($PO_4{^{3-}}-P$) in aqueous solutions were also studied in various experimental conditions. As a result, the developed coagulants are found to show a good removal performance of heavy metal ions. turbidity and phosphate phosphorus in aqueous solutions.

  • PDF

Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River (낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성)

  • Hwang, Deok-Heung;Kim, Dong-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF