• Title/Summary/Keyword: tunnel failure

Search Result 446, Processing Time 0.025 seconds

Probability Distribution of Geotechnical Properties of Songdo area in Incheon (인천 송도지역 지반정수의 확률분포 추정)

  • Kim, Dong-Hee;Kim, Min-Tae;Ko, Seong-Kwon;Park, Jung-Gyu;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1399-1406
    • /
    • 2009
  • Probability distribution of geotechnical properties is very useful information and it is used for evaluating the geotechnical properties itself and calculating probability of failure. In this study, probability distribution of compression index, recompression index, and void ratio are evaluated, and analysis results show that all property distributions satisfy normal and log-normal distribution.

  • PDF

Diabetic Neuropathy (당뇨 신경병증)

  • Shim, Jung-In;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.251-256
    • /
    • 2013
  • Neuropathy is a common complication of diabetes. It is characterized by a progressive loss of peripheral nerve fibers. The development of the neuropathy is linked to poor glycemic control, age, and the duration of diabetes. Peripheral sensory polyneuropathy is the most common type in neuropathy. Diabetic neuropathy is the most significant etiologic factor of the foot ulcer that may leads to amputation. Current treatments in diabetic neuropathy have no definitive effects on repair or reverse the damaged nerve but only to relieve of symptoms, especially on pain. When the focal compressive neuropathy is combined with diabetic neuropathy, the nerve would be more vulnerable and symptoms might get worse. Surgery is indicated for decompression of an entrapped nerve, like posterior tibial nerve in tarsal tunnel, after failure of the initial conservative treatments.

Quantitative Risk Assessment Method for Deep Placed Underground Spaces (대심도지하공간의 정량적위험성 평가기법)

  • Lee, Chang-wook
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.1
    • /
    • pp.92-119
    • /
    • 2010
  • As the necessity to utilize deep-placed underground spaces is increasing, we have to seriously consider the safety problems arising from the U/G spaces which is a restricted environment. Due to the higher cost of land compensation for above ground area and environmental issues, the plan to utilize deep-placed U/G spaces is currently only being established for the construction of U/G road network and GTX. However it is also expected that the U/G spaces are to be used as a living space because of the growing desires to change the above ground areas into the environmentally green spaces. Accordingly it is necessary to protect the U/G environments which is vulnerable against desasters caused by fire, explosion, flooding, terrorism, electric power failure, etc. properly. We want to introduce the principles of the Quantitative Risk Assessment(QRA) method for preparedness against the desasters arising from U/G environments, and also want to introduce an example of QRA which was implemented for the GOTTHARD tunnel which is the longest one in Europe.

Percutaneous Tunnel Ventriculostomy for the Hydrocephalus Complicated with Ventriculitis - Case Report - (뇌실염이 합병된 수두증환자에서 피하터널 조루술 - 증례보고 -)

  • Hwang, Sung-Nam;Cho, Jae-Young;Park, Seung-Won;Kim, Young-Baeg;Choi, Duck-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.939-942
    • /
    • 2001
  • Thirty nine-year-old man who required urgent shunt operation due to rapidly deteriorating visual acuity suffered from ventriculitis after aneurysmal operation. Daily dose of 20mg of vancomycin and amikyn were given intraventricularly via external ventricular catheter after failure of various kinds of systemic antibiotics. The exit of the catheter was made on the upper chest wall to prevent superinfection. External ventricular drainage could finally be switched to ventriculo-peritoneal shunt and he was discharged with clinical improvement.

  • PDF

Stability analysis of homogeneous slopes with benches

  • Zhao, Lianheng;Xia, Peng;Xie, Rongfu;Li, Liang;Zhang, Yingbin;Cheng, Xiao
    • Geomechanics and Engineering
    • /
    • v.13 no.3
    • /
    • pp.517-533
    • /
    • 2017
  • In this paper, with a graphical approach, a series of stability charts for homogeneous slopes with benches are presented based on the upper bound limit analysis theory and strength reduction technique. The objective function of the slope safety factor $F_s$ is optimized by the nonlinear sequential quadratic programming, and a substantial number of examples are illustrated to use the stability charts for homogeneous slopes with benches driven by only the action of the soil weight. These charts can be applied to quick and accurate estimations of the stability status of homogeneous slopes with benches. Moreover, the failure modes and the formula for safety factor Fs of homogeneous slopes with benches are provided to illustrate the stability analysis of slopes with benches, which is validated by samples.

3D stability of shallow cavity roof with arbitrary profile under influence of pore water pressure

  • Luo, W.J.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • v.16 no.6
    • /
    • pp.569-575
    • /
    • 2018
  • The stability of shallow cavities with an arbitrary profile is a difficult issue in geotechnical engineering. This paper investigates this problem on the basis of the upper bound theorem of limit analysis and the Hoek-Brown failure criterion. The influence of pore pressure is taken into consideration by regarding it as an external force acting on rock skeleton. An objective function is constructed by equating the internal energy dissipation to the external force work. Then the Lagrange variation approach is used to solve this function. The validity of the proposed method is demonstrated by comparing the analytical solutions with the published research. The relations between shallow and deep cavity are revealed as well. The detaching curve of cavity roof with elliptical profile is obtained. In order to facilitate the application of engineering practice, the numerical results are tabulated, which play an important role in tunnel design and stability analysis of roof. The influential factors on potential collapse are taken into consideration. From the results, the impact of various factors on the extent of detaching is seen intuitively.

A rough flat-joint model for interfacial transition zone in concrete

  • Fengchen Li;J.L. Feng
    • Computers and Concrete
    • /
    • v.34 no.2
    • /
    • pp.231-245
    • /
    • 2024
  • A 3D discrete element model integrating the rough surface contact concept with the flat-joint model is suggested to examine the mechanical characteristics of the interfacial transition zone (ITZ) in concrete. The essential components of our DEM procedure include the calculation of the actual contact area in an element contact-pair related to the bonded factor using a Gaussian probability distribution of asperity height, as well as the determination of the contact probability-relative displacement form using the least square method for further computing the force-displacement of ITZs. The present formulations are implemented in MUSEN, an open source development environment for discrete element analysis that is optimized for high performance computation. The model's meso-parameters are calibrated by using uniaxial compression and splitting tensile simulations, as well as laboratory tests of concrete from the literature. The present model's DEM predictions accord well with laboratory experimental tests of pull-out concrete specimens published in the literature.

An Investigation on the Characteristics of Local Factors of Safety of Rock Failure and Their Dependency on the Stress Paths (암석파괴 국부안전율의 특성과 응력경로 의존성 고찰)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.27 no.1
    • /
    • pp.39-49
    • /
    • 2017
  • The factor of safety (FOS) is commonly used as an index to quantitatively state the degree of safety of various rock structures. Therefore it is important to understand the definition and characteristics of the adopted FOS because the calculated FOS may be different according to the definition of FOS even if it is estimated under the same stress condition. In this study, four local factors of safety based on maximum shear stress, maximum shear strength, stress invariants, and maximum principal stress were defined using the Mohr-Coulomb and Hoek-Brown failure criteria. Then, the variation characteristics of each FOS along five stress paths were investigated. It is shown that the local FOS based on the shear strength, which is widely used in the stability analysis of rock structures, results in a higher FOS value than those based on the maximum principal stress and the stress invariants. This result implies that the local FOS based on the maximum shear stress or the stress invariants is more necessary than the local FOS based on the shear strength when the conservative rock mechanics design is required. In addition, it is shown that the maximum principal stresses at failure may reveal a large difference depending on the stress path.

Calculation of Failure Load of V-shaped Rock Notch Using Slip-line Method (Slip-line법을 이용한 V형 암석 노치의 파괴하중 계산)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.404-416
    • /
    • 2020
  • An analytical procedure for calculating the failure load of a V-shaped rock notch under two-dimensional stress conditions was developed based on the slip-line plastic analysis method. The key idea utilized in the development is the fact that the α-line, one of the slip-lines, extends from the rock notch surface to the horizontal surface outside the notch when the rock around the notch is in the plastic state, and that there exists an invariant which is constant along the α-line. Since the stress boundary condition of the horizontal surface outside the rock notch is known, it is possible to calculate the normal and shear stresses acting on the rock notch surface by solving the invariant equation. The notch failure load exerted by the wedge was calculated using the calculated stress components for the notch surface. Rock notch failure analysis was performed by applying the developed analytical procedure. The analysis results show that the failure load of the rock notch increases with exponential nonlinearity as the angle of the notch and the friction of the notch surface increase. The analytical procedure developed in this study is expected to have applications to the study of fracture initiation in rocks through wedge-shaped notch formation, calculation of bearing capacity of the rock foundation, and stability analysis of rock slopes and circular tunnels.

Structural Analysis of Cheju-style Plastic Greenhouse Model for Crop Growing Based on the Wind Load (풍하중을 고려한 제주형 작물재배용 비닐하우스모델의 구조해석)

  • 민창식;김용호;권기린
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.181-190
    • /
    • 1998
  • An elastic analysis under wind load was performed for the double layered plastic greenhouse model developed particularly for minimizing damages under typhoons at Cheju Citrus Research institute in Seagipo city. General EVA film was used for the inner covering and the developed special film which would break the wind pressure down was used for the outer covering. The wind tunnel test showed this special film reduced the wind speed up to 86 to 98% under well controlled situation. Based on the elastic analysis performed in the study, the behavior of the greenhouse was changed significantly due to the boundary conditions. Not like other researchers before we applied dead load of the concrete support to the ground pipe and fixed support boundary conditions at the 4 corner pipes. The analysis shows that the greenhouse was lifted and pulled the pipe out of the ground due to the sucking wind pressure. The behavior of the greenhouse was quite similar to that one real greenhouse failure. Therefore, not only we need to find the realistic boundary conditions for the supports, but also need to find how to rest the pipe supports on the ground without economic loss.

  • PDF